HomeMy WebLinkAbout1000 Ute Forest Ln - 210704401002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1896-99 BP NO. 12673
OWNER: PHILIP AND JOSI WASTERVAL PHONE:
MAILING ADDRESS: 2007 S BLVD, HOUSTON, TX 77098
APPLICANT: JOSEPH ABBOTT CONSRUCTION PHONE: 970-907-0367
SYSTEM LOCATION: LOT # B-2, UTE FOREST na, SQUAW CREEK, EDWARDS, CO TAX PARCEL NO. 2107-044-01-002
LICENSED INSTALLER: DAVIS EXCAVATING, JUSTIN AHRING LICENSE NO. 8/99 PHONE: 970-926-3788
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON SEPTIC TANK 563 SQUARE FEET OF ABSORPTION AREA VIA 18 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 7/2/99. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. BUILDING CER-
TIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL.
ENVIRONMENTAL HEALTH APPROVAL: CTI, LAAAAA JULY 16, 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 563 SQUAREFEET(VIA_ IS STANnARD TNFTT.TEATog 11NTT2
INSTALLED CONCRETE SEPTIC TANK:1000 GALLONS IS LOCATED DEGREES AND FEET FROM
SEE SITE PLAN FOR SYSTEM CnMPnmF.w LL)C TIC)NS
COMMENTS: ENGINEER FINAL CERTIFICATION RECEIVED 10/3/99. TANK IS LARGE ENOUGH FOR 3 BEDROOMS,
BUT THE LEACH FIELD IS ONLY LARGE ENOUGH TO ACCOMMODATE 2 BEDROOMS.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE'A RE -INSPECTION WHEN WORK IS
COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL 6L JJJ� DATE: OCTOBER 6, 1999
Incomplete
(Site Plan
Applications Will NOT Be Accepted
MUST be attached)
ISDS Permit # ( 0 G`
Building Permit # 7_3
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE._- EAGLE COUNTY-
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
*
*
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER: �'� (J t Ja5 (� A5�4, (L -
MAILING ADDRESS: tb- PHONE
APPLICANT/CONTACT PERSON: �'1�� � kb (l LtI`' 4w(A� PHONE: 3�"7
LICENSED SYSTEMS CONTRACTOR: bC3�C5 'F-- 14C-(1, oct� PHONE:
COMPANY/DBA: ADDRESS:
***************************************************************************
PERMIT APPLICATION IS FOR: (-�' NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: - �it2 '�U�S+ At wesi L o-�e
Tax Parcel Number: oZIn '0 q-01-00.Z Lot Size:
Physical Address: ��Q �¢ sI'1'011� cye' ,
UILDING TYPE: (Check applicable category)
(�T Residential/Single Family Number of Bedrooms
( ) Residential/Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF_WATER SUPPLY: (Check applicable category)
(n Well ( ) Spring ( . ) Surface
( ) Public Name of Supplier:
*These systems requ' e d signby a � tered Professional Engineer
SIGNATURE: wjDate: - �9
AMOUNT PAID: I5 V .� RECEIPT # : g DATE: 7
CHECK #: 3 /.h`'? CASHIER:
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
Date: July 16, 1999
TO: Davis Excavating
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1896-99. Tax Parcel
# 2107-044-01-002. Property Location: Lot #13-2 Ute Forest @ Squaw.Creek
Edwards, Wasterval residence.
Enclosed is your ISDS Permit No. 1896-99. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications,
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vait.net
http: //www.eagle-county.com
October 6, 1999
Philip and Josi Wasterval
2007 S. Blvd.
Houston, TX 77098
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1896-99, Tax Parcel #2107-044-01-002. Property location: 1000
Ute Forest Rd., Edwards, CO.
Dear Mr. and Mrs. Wasterval:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
I OF U41 I=-J t3d. 4z yrn—y�b-bJUbj LKP ENGINEERING, INC PAGE 01
CI"ViUGBGTEaMOM
October 4, 1999
Mr. Torn Peterson ` : inspection idl a !tttent hattallatlon
Morter Taker Architects Lot B-2, Ute ForetAt Wftt:�Oaw Creek
c/o Philip BSc Jose Wastexval .'Eagle County, C616rodo
143 E. Meadow Drive Project No. 993.o$ - Septie'System Permit No. 1896-99
Vaii, CO 81657
Dear Toth:
At the request of Scotty Davis +w.it�G:) is Exc°avatirl `bn' Septoit�bet 28 and October 1, 1999, we
visited the construction site for tiled"Wastct l Cabin at Lot 8-2;:Ute Fo ' t at West Squaw Creek, Eagle
County, Colorado. The purpose 6(dur sita:..visits wes to observ�'.the ias�llation o#"the septic system.
They installed the syste.wln ovetill:compliance withi% sep6d,*tystern design, Drawing No.
9910SS0.DWG, dated July 2, 1090. Thb a em was installed.els ahovvri'*n the above -named drawing, but
was connected closer to the sott*Wt cotti,. They installed 1.-gagpoi two compartments, a precast,
concrete septic tank. The tame had2-12"ors on troth inspectitoo covers.
Eighteen, Standard Tnfi3trii�tu Ch0bers were instal yin two tenches with 9 Infiltrators each.
Tlie infiltrators were connected Oft serfid istribution. In tha.,` st irz�Clid'ator of each trench, inspection
ports were installed. Horizontal diatande, ►im center to cent'es':'dthe t'#'ic ches, was 9 feet or more. All
piping was SI R-35, 4-inch PV'C. 'iiie ; of the trenches two ta three feet. The soil profile in fire
trenches was consistent with tboo6 l 6444b.0d in the profile,mitre log. .
If you have any questWi' pleasi4ca not hesitate to ci jk
Sincerely,
LKP ling
Uiza Petrovska,
President'
cc: Ms. Heather Savalox, Enee Cosh Env ironmmental`;E Wth DiViiion, fax: 328-7185
(:\MyP'ile,lccuclJiwlWlyDRf:SdW1060STWP6
P,O, Box. 2937, Edwards, 8163i,�:;.(970) 92+6-9088 Tti : {910 4i6-9089 Fax, E-mail: lkpeng@sn.owcap.net
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Location: Lot B-2, Ute Forest at Client: Philip & Jose Wasterval
West Lake Creek 2007 S. BLVD
Eagle County, Colorado Houston, TX 77098
Project No.: 99108
P-1
P-2
P-3
TR\AE/DEPTH
2111
24"
18"
10
12"
6-10/16"
10"
3-4/16"
9-12/16"
1-4/16"
10
12-6/16"
6/16"
11-14/16"
1-14/16"
13-12/16"
3"
10
14-4/16"
1-14/16"
13-4/16"
1-6/16"
15-4/16"
1-8/16"
10
15-10/16"
1-6/16"
14-4/16"
1"
16-4/16"
1"
10
16-10/16"
1"
15-4/16"
1"
17-4/16"
1"
10
17-10/16"
1"
16-4/16"
1"
18-4/16"
1"
10
18-10/16"
1"
17-4/16"
1"
19-4/16"
1"
PERC RATE
10 MIN/INCH
10 MIN/INCH
10 MIN/INCH
AVG PERC
10 MINUTES PER INCH
Average Percolation Hole Diameter: 10 Inches
Holes Dug and Presoaked: June 7, 1999
Test Run: June 8, 1999
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Location: Lot B-2, Ute Forest at Client: Philip & Jose Wasterval
_ West Lake Creek 2007 S. BLVD
Eagle County, Colorado Houston, TX 77098
Project No.: 99108
P-1
P-2 I
P-3
TWE/DEPTH
2111
24"
18"
10
12"
6-10/16"
10"
3-4/16"
9-12/16"
1-4/16"
10
12-6/16"
6/16"
11-14/16"
1-14/16"
13-12/16"
3"
10
14-4/16"
1-14/16"
13-4/16"
1-6/16"
15-4/16"
1-8/16"
10
15-10/16"
1-6/16"
14-4/16"
1"
16-4/16"
1"
10
16-10/16"
1"
15-4/16"
1"
17-4/16"
1"
10
17-10/16"
1"
16-4/16"
1"
18-4/16"
1"
10
18-10/16"
1"
17-4/16"
1"
19-4/16"
1"
PERC RATE
10 MIN/INCH
10 M1N/1NCH
10 MIN/INCH
AVG PERC
10 MINUTES PER INCH
Average Percolation Hole Diameter: 10 Inches
Holes Dug and Presoaked: June 7, 1999
Test Run: June 8, 1999
1896-99 Tax ifZ1U/—V44—V1—vVc
Lot B-2, Ute Forest WASTERVAL
IWOB NAME At West squaw Creek JOB NO. � (�(o 15
Edwards
LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
h Z - _
goo z
-s= dK 4o
10p -�
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 277
JOB FOLDER
Printed In U.SA
i
10
`— 22-1 /2 'ELBOW ' '� . �. ,ij.i/ — V = 563 gallons o
J /i !i / \ _ -- _ Use 1000 gallon, two compartment precast concrete tank by Copland Concrete or equivalent
90' ELBOW ' : ii/- \ —
. ABSORPTION AREA
/
A — max 5 T
/i// i //i/ `� — A = O 5 x V10 94285 s f.
c / //i/ \ 1
� lNFIL TRA TOR // i / / � � _, . �
CHAMBER // ij // \ ` Amax = 285 s. f.
Based on App/icotio Rote: Q
A-450 d08 dsf
//
E C4E OF FL> �V POAn �_ A = 563 s. f gP
:.... .
- -O" GRAVEL W%.KWAY \ \ \\ 2
showsTOPAGE AMA Standard /nfe/trator Chamber System in a trench configuration with on al/owed 50 percent
reduction in the absorption area is recommended
o �Acorrected = 282 s. f.
Surface area of one Infiltrator Chamber = 15.5 s f.
Use 18 Infiltrator Chambers in two trenches with 9 Infiltrators in each.-
�._ 990
50' ACCESS AAND U71UTY EASE
�//
40
L6
\ NOTES
9 1. The building sewer line from the house to the septic tank shall have a maximum slope of 114 inch per Z) Ce-
foot. Bends in the building sewer shall be limited to 45 degrees.
CC Li-
.7; �_ 2. The septic tank shall be installed level. The tank shall have removable covers or manholes to within 8 W Q Q V
inches of the finished gradeg,�or inspection and cleaning. 0 W
— J. Excavate three (3) feet wide trenches. The horizontal distance from sidewall to sidewall between the - � ' Q Q
GrAVEL !'A.7N V' SNOW STOtZAGE AREA `\
— trenches shall be a minimum of six (6) feet. t„/ W V
\ / �— 4. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing. r .` if•�41 �i
WELL \ V � O� .
/ MSC. F'LAN7Et7 sl-�.r3s r0
5CMEN PATIO \ \ — 5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers �- W
recommendations. .
6. Backfill the sidewall area with native on —site soil for proper support. W
O
-- i 7Backfill the trenches with a minimum of 12 inches of tamped soil cover. —j
8. Avoid vehicle traffic over the system.
9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division,
80
82 Chapter 4, Individual Sewage Disposal Systems.
I I�:�I Ills
I h \ 10. The Septic System Installation shall be inspected by the Design Engineer prior to bockfillin .
P 9.
_
>...• : ;> ... ,- 88-- PERCOLATION PEST RESULTS 0)
�—
' ' '� Pt2E5EiZVE ANf7 PtZOTECt EXfSTING Perc No. 1 Perc No. 2 Perc No. 3
} VEGITATION AIZOUNt7 Da{Li21NG 51?. / CV (D
I I l ! E/ — 10 minutes per Inch 10 minutes per Inch 10 minutes per Inch
PLL t715TL1a3Er? PEAS t0 3E i�SEEt7ECJ / P P7 I - -
`r'• TO MATCH 5UIZOL:Nt7IN6 NATIVE i CD
\ / / / Average percolation rate recommended for design T a 10 minutes per Inch. 00 N NV 5� i2 X35. ' \ G!zP55E 5
108' 7 O
\` w 00
SOIL PRonLF U t�
PROFILE HOLE #2 _ � � v
ASPEN T ELIr i / PROf7LE HOLE #1 ao to 3.0 foot TopsoA U e v
0.0 to JO foot Topsofl 3.0 to 8.0 feet Light brown, � � "-
`_� i 3.0 to aO feet Light brown, cla)ey-sandy gravel to gravelly sand C W
clayey -sandy grovel to gravelly sand (weathered bedrock) W 00
(weathered bedrock) 00
4" DIAM BLDG SEWER r — / / / �
AT 1/4" PER FOOT MAX. �� ' n 1
00.1
c0
1000GALLON CONCRETE' SEPTIC TANK'
o O �ROF7CE HOLE , 2 / / / / / BY COMM CONCRSlE OR EQUIVALENT �I co 0
d �
-1rANOUT 1000 CAL TWO P. -1 90 j
TOP VIEW
,68 \ CONC. SEPTIC TAN f f / 1 j / / 00
66
' AFa20W5 IPJi71CATE 511E l7l'AtNPGE --------- ----
6� REP ANd IAMITI _ r-------- i @------ -i
72 � � � I 1 r 1
6 MOUNTAINS \ i 56.25/ / / / / +
P-2
SERIAL DISTRIBU77ON / Q r r 1 1
SEE. DETAIL A -A 1 r 1 r
MIIY / 1 t i i 1
9?O
-
\ '
/ STANDARD lNFIL IRA TOR 1 r t
/ TYPICAL
4o`4ii9949@@@@@Rllpeeeegje
PROf7LE HOLE yl_,' f / ' / / i �•� % 2• �9 '©
SIDE VIEW :0
INSPECRON PORT
ieeeeeeulH lilt
DRAWN 8Y L.P.
CHECKED 8Y L. P:
r/
/ / j PROJECT NO.. '' 99108
f
6.25'
STANDARD INFILTRATOR / ' / DRAWING NQr-99108SD.DWG
N07E SIT PLAN BY MOVER AKER ARCHIIFCTS SHEET 1 OF. 1
N. T.S.
GRAPHIC SCALE
0 5 10 20
( IN FEET )
1 inch - 10 ft_
,A)MOW5 IN7ICATE 51Y r7tZA NAGE
EXISTING CONTOLR \
Q�VI5ED CONTOW
DOLLMIZ MTAINING WALL
T.O. WALL 76.5' (�
D.O. WALL 74.0 r
\Z \
\Z \.
u
N
GAME 0! -M
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2078-01 BP NO. 13 572
OWNER: JOSI AND PHILIP WASTERVAL PHONE: 713-630-0843
MAILING ADDRESS: 2007 S BLVD., HOUSTON, TX 77098
APPLICANT: JOSEPH W. ABBOTT PHONE: 970-748-1587
SYSTEM LOCATION: 1000 UTE FOREST LANE, EDWARDS, CO TAX PARCEL NO. 2107-044-01-002
LICENSED INSTALLER: DAVIS EXCAVATING, JUSTIN AHRING LICENSE NO. 27-01 PHONE: 970-926-3788
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 2 BEDROOM RESIDENCE
1000 GALLON SEPTIC TANK, 1000 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 34INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 12/27/00, WITH A CLEANOUT BETWEEN THE HOUSE, AND INSPECTION
PORTALS IN EACH TRENCH. INSTALL WITHIN 12 INCHES OF FINISHED GRADE, AND BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIRE-
MENTS. RAKE ALL TRENCH SURFACES, AND DO NOT INSTALL IN WET WEATHER. ENGINEER IS RESPONSIBLE FOR FINAL CERTIFICATION BUT
EAGLE COUNTY ENVIRONMENTAL HEALTH MUST ALSO VIEW THE INSTALLATION PRIOR TO BACK FILLING. CALL WELL IN ADVANCE FOR
THE FINAL INSPECTION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN IN-
SPECTED AND APPROVED. {I
ENVIRONMENTAL HEALTH APPROVAL DATE: APRIL 9, 2001
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL
AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 992 SQUARE FEET (VIA 32 INFILTRATOR UNITS PER DF S T GN )
INSTALLED CONCR F TEK:10 0 0 GALLONS IS LOCATED go DEGREES AND ? 9 FEET INCHES
FROM THE CLEANOUT ON THE SOUTH SIDE OP THE HOiISF.
COMMENTS: THE FINAL INSPECTION WAS DONE BY WILLIAM CARLSON AND THE. DESIGN EN-
GINEER ON JULY 191, 2001- THE ENGINEER'S PTNAL CERTIFICATION WAS REOEDVED ON
SEPTEMBER 26 2001. THIS SYSTEM IS LARGE ENOUGH FOR A @ BEDROOM
ANY ITEM NOT MEETING REQUIREMENTS WtIsL� CTED FIN PPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED. t
ENVIRONMENTAL HEALTH APPROVAL DATE: SEPTEMBER 27. 2001
Incomplete Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit #
Building Permit
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823
**************************************************************************
* FEE SCHEDULE
* PERMIT APPLICATION FEE $150.00
* PERCOLATION TEST/SOIL PROFILE AND SITE EVALUATION FEE $200.00
* SITE VISIT/CONSULTATION FEE $85.00
* REINSPECTION FEE $47.00
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
**************************************************************************
PROPERTY OWNER: 1' I' I r + mrS. Dl�>; 4 Irk r' 10 1A)
MAILING ADDRESS: �� i I� S (7 e�� S ��iOPHONE :
APPLICANT/CONTACT PERSON: ��,c�Se- L4� PHONE: -15-9
LICENSED SYSTEMS CONTRACTOR: DCLJ PHONE:
COMPANY/DBA: QA.> GG s_. fCt ADDRESS: 2ri) ab X )39y E!�JM" 4f
***************************************************************************
PERMIT APPLICATION IS FOR: Q() NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description:
r
Tax Parcel Number:
Lot Size:
Physical Address:
Wei L)'
BUILDING TYPE: (Check applicable category)
() Residential/Single Family
( ) Residential/Multi-Family*
( ) Commercial/Industrial*
Number
Number
Type _
of Bedrooms
of Bedrooms
*These systems require design by a Registered Professional Engineer
TYPE OF WATER SUPPLY:
(X) Well ( )
( ) Public Name
APPLICANT SIGNATURE:
AMOUNT PAID: /5-d acs
s!'1G �A�tak w
(Check applicable category)
Spring ( ) Surface
of Supplier; ,
Y W . Date: /
RECEIPT # : cJ DATE: #M.*,&
CHECK #: 1L,�-i�o°" CASHIE
C14&K ii
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: April 9, 2001
TO: Davis Excavting
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No.20781-01. Tax Parcel
#2107-044-01-002. Property Location: 1000 Ute Forest Lane, Edwards, CO.,
Wasterval residence.
Enclosed is your ISDS Permit No. 2078-01, and a field copy of the engineer design stipulated on
the permit. It is valid for 120 days, or for the duration of your current building permit for this
property. The enclosed copy of the permit must be posted at the installation site. Any changes
in plans or specifications invalidates the permit unless otherwise approved. Please note any
special requirements that may have been added to the design by this department.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County Environmental Health
must also view the installation prior to back filling. Please call well in advance for your
final inspection. Your TCO will not be issued until our office receives this certification
from the engineer, and views the installation.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements. Please
notify this office if you have not been contracted to perform this installation.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
September 27, 2001
Josi and Paul Wasterval
2007 S. Blvd.
Houston, TX 77098
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #2078-01, Tax Parcel #2107-044-01-002. Property
location: 1000 Ute Forest Lane, Edwards, CO.
Dear Mr. & Mrs. Wasterval:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely, j
Janet Kohl
Eagle County Environmental Health Department
ENCL: Informational Brochure
Final ISDS Permit
cc: files
L111 LI YkA lI`ILLI\11 I%A 11 V\-t
rritac U.L I t -L
ILKPI Engineering, Inc.
SenteMber 26, 2001
Philip & OSi Wasterval.
2-007 S Boulevard
Houstorx, LX 7'7n9Q
Dear Philip & Josi:
Jr_ -A L.7 rkwo:4 SiTrSlem IuA-.uuu:3tihUn
Wasterval Residence
1000 Ute .forest Lane
Eagle County, Colorado
Project No. 99108 - perm..-itN�_ 20781-01
At the request of doe Abbott, on July 19, 2001, we visited the construction site for the
�wasterval Reszdextce at 1000 Ute Creep Road, Eagle County, Coj.orado. The purpose of our site visit
was to observe the installation of the septic system,
They installed the system in overall compliance with the septic system, design, Drawing No.
991 OSSDMATN_Dwc; dated December 27, 2000_ The system was installed as shown on the above-
uamed drawing_ 'f iey installed a 1000-gallon, two compartment, precast,. concrete septic tank. A cleanout
ova aw wii u LLM-en the house And the septic tank.
T irty two, Standard Infiltrator Chambers were installed in two trenches. Each row contained 16
i nnlrrators. The infiltrators were connected with serial distribution. At each end of the trenches,
inspection ports were installed- Horizontal distance from center to center of the trenches. was 9 feet or
more. All the piping was SDI -35, .4-i neb PVC. The depth of the trenches was no more than 36 inches -
If you have any questions, please do not hesitate to call.
Sincerely,"•:+."�
LKP Engineering,
i et ovska, r l
T7--- xi :.i �a4
F e3Went
cc: Ms. Laura Fawcett, Eagle County Environmental Health Division., fax: 328-0349
110etmv2yp4kWYFIIcokoreldo6lW MC)CUWI08main.ogl,wpq
-P;o; Box 283?, Edwards, CO 81632, IWO) 924-9088 Tel (970) 926-9089 Fax
SFP-pG.-pnni wpn Md- 1 SIDM Tn-Gnr-i � f`n1 IKITV Chll I 4dCnl TI.-I onr_c- 4
L
03/29/2001 10:29 9709269089
MAY 24-1999 M0
1i 12:31 PM MORTER AKER ARCHITECTS
4epworthPaWlak Geotech TE.L=970-945-8454
i030
1
t
t
A LKP ENGINEERING INC
FAX NO. 9'f U4 rbu r I u
May 24 99
1030
X
/
//1020 101b
BORING 7 • / 00RING
AESIDENCY ARE / J
1 BORINi,0 P ^/ J
BORING i BORING 12q
J ! J
3dJP 2 J� I
rJ pQ r
� AQR�NGI �
J
1020
APPROXIMATE 'SCALE.
1" a lob,
PAGE 01
10;24 N0,011 P.02
ACCESS AND UTILITY
EASEMENT
ai
6
z
s.
1 98G CL Jr ju ILL. lu-
/ 070
r
ORI BORING / G/i ", ", C
goo BORING
-I rOING (:Al31N
970 AOOO
199 304 1 HEPWORTH -- PAWL -AK 1 LOCATION OF EXPLORATORY BORINGS � FIg. 1
GEOTEQHNICAL, INC_
Received Time Mar,29. 10:45AM
03,/29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 02
MAY-24-1999 MON 12:31 PM MORTER AKER ARCHITECTS FAX NO. 970470W N r, w
HepworthPawlak Geotech TEL.;970--945-8454 Mag 24 99 10:24 No.011 P-03
U
5
ire]
20
25
CABIN AREA
PROFIIA-: PROFU PRDRLE
r BORING 1 BOF�ING 2 6oRIN0 BORINS �f NOSING 5
ELEV. �► 9B0' ELEV. 8l30' ELE:V, 975' ELLV. = 971' ELEV. va 9'I3'
WC-12.4 �yh2 8A/12
W-106
-20v+�q
6DJ7 Seto �R/8 6p/4
Wells
50/Z M 3oA
80/1 1 50/2
Wo
Note: Explono4+An of s"bolS It Shawn on 1"19. 5.
199 304 1 HE.PWORTH — PAW1.AK
GEOTECHNICALl INC.
Received Time Mar.29. 10:45AM
20
25
LOGS OF" EXPLORATORY 8ARINGS ' Flq. 2
0,�/29/2001 1.0:29 9709269089 A LKP ENGINEERING INC PAGE 03
MAY-24-1999 MON 12:31 FM MORTER AKER ARCHITECTS FAX NO. 97U4.16U(1U r. U4
HepworthPawlak Geotech TEL:970-945-8454 May 24 99 10125 No.011 P.04
RESIDENCZ AREA
PROF•iLE
BORING 6
BORING 7
BORING 8
BORING 9
ELEV, = 1012'
ELEV. 0 10,32'
ELEV. - 1028'
1:11"V, T 10?2'
0
1�
0
27112 '
5D/o
16AZ
44/11.
W(>; 4,0
+4-44
g
.• 2eo�11
7�
14/12
50/4
14/I2
s4/1F
10
10
d
IU
U
�
til
8
{a
X
.K
I
�
s
50/3
d8/72.7/8
17/12
we A&
wo¢2t.o
1 S
.1•4-39 -• 200-46
•-Z00et4 LLuA-
P1R I B
C1 26/12 511/0
20 2.0
25 is 25
WQ
10
30 �0
Note; FxplhnotTon of symbolu 16? uhown on Fig, 5.
199 304 HEPWORTH — FAVVLAK LOGS OF UPLORATORY I30RIN(yS FIg. 3
GEOTEr,HNICAL, INC.
Received Time Mar•29, 10:45AM
03�29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 04
MAY-24-1999 MON 12:32 PM MORTER AKER ARCHITECTS FAX NU. MC UU M F. W
HepworthPawlak GeoteGh TEL=970-945-8454 May 24 99 10:25 N0.011 P.05
A
RESIMNU AREA
PROr 1LL
HORiKc 1A PORING 17
BORING 19
uu. Iwo, CLE_b. toll'
tjEv. — 10111'
D
0
.so/tl �D/A
5
5
�1.
10
wo—B-C w4�3.6
1U
—?A6�1J ••20�+11
1
15
�
I
0
15
20
ao
25
25
Nate: Explunotlon of gymbolo IA gkoWr1 on Ffg.
5.
199
304
HEPWORTH -•- PAWLAK
LOGS OP LXPLORA-f0RY DORINGS
i icj. 4
GEOTECHNIC;AL, INC.
Received Time Mar.29. 10:45AM
03,/29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 05
IlAY-24-1999 MON 12:32 FN MORTER AKER ARCHITECTS FAX NU. UU411JU M r• ua
HepworthPawlak Geotech TEL:970-945-8454 hay 24 99 .10;26 No.011 P.06
i
LEGEND,.
TOPSOIL, handy slity cloy, orgonlc, with ecottored basalt eobblotl end bouldors In raRldenco
area, eaft to medium stiff, moist, dark brown.
CLAY (Cl..); Brandy with basolt fragments. stiff to very stiff, moist, groy--brows►. Boring 6 only.
SAKI) AND CLAY {5C—GI..}; with buoolt frogmenla, very stiff to hard, motert, orange, calcorenva.
.+ BASALT CRAM. {t3C (3M): slightly clayey to Billy, Bondy. With basalt cabbies and scottarnd
nolildor-F, madlum donne matrix rtotls,.,eli{lhtly.moist tv mold, groy.hruWn.
WEATHEREO 5iLTSTONE/SANDSTONE: altghtly mol5t, brown.
SIUSTONC/SANDSTONE BEDROCK. hard iv very hard, calGaraous, sorrit gypsum, yellow brown,
Eagle Volley Evaporite Formation.
Relatively undistvrbed drive sornplo; 2-1nch 1.0- California lititr sample_
Drive sample; standord penctration test ( 591 ). 1 3/8—inch I.D. split spoon aornpla, A5TM 0 — 1586.
'l6/11. Drive sample blow count, lndlcat@s that 26 blows of a 14r1—pound hammer falling 30 Inches were
required to drive She California or SPT 4grppler 12 inchos.
TPrcicticol rig rsfusat. Where showh above bnitdm of log, Irldieot4pn multiple attempts were made
to advance the boring.
NOTES:
1, kxplorotgry borings were drilled on April 14 and 15, 1990 With o 4-.inch diomotRr continuous Tlight powor.
2. Locations of exploratory borings ware rnngrured opproximatoly by paoing from foptkirr..v shown
on tho site plan provided.
3. Elevations of exploratory boririgs wares obtolnCd by Interpolation between cnntours On the site plan
provided and aheoked by Instrument level.
4. The exploratory boring locations pnd elevations ahorld be 0one7dered accurate only to thft dogrpq Impliod
by the method used,
5. The IInos between materials shown pn tho axploratory borinq lo93 repre5orlt tho approxinote houndorioa
bctwcen material types and transitions may be gradual.
6. No frog .water was encountered in the borings '61 the time of drilling.'
Fluctuation in water lavei mdy occur with time.
7. Laboratory Tovtino Results:
WC Wvtar Content ( X )
DO Dry Density ( pC9 ) 1-Tquld Limit
4-4 = Percent reteinnd on No. 4 sieve. Pi Plosticity Index { X }
--200 - Porcant positing No, 200 slave.
199 304 1 (W", CwTCRTH C1fiNICA AWLA LEGEND AND NOYLS I Fig, 5
Received Time Mar•29. 10:45AM
KV 29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 06
MAY-24-1999 MON 12:33 PM MORTER AKER ARCHITECTS FAX NO, y MIJU H U r. ul
HepWurthPawlak Geotech TEL)970-945-8454 May 24 99 10;26 Na.011 P.07
a
R
0 1 1,p 10 100
ApPUED PR>rS$UK — k%f
►t 0
2
--
-
Moisture Content :r 113 prmsmt
Dry Density - 113 pcf
Sampl© of- Wnothared Slllstona
From, Boring 2 of 4 Fnet
-
upon
walling
0.3 1A 10 too
APPLIED PRMUM kvf
1.99 304 JHEFYVORTI-i — PWLAK SWELL --CONSOLIDATION TFST RE'S111Ti Fig. 6
ai~0-TV�CNNiCAL, INLI,
Received Time Mar.29, 10:45AM
0a/29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 07
MAY-24-1999 NON 12:34 PH HORTER AKER ARCHITECTS FAX NU. VU4(bUllU r. U0
HapWorth?awlak Geatech'TEL-970-945-8454 May 24 99 10 ;.27 No , 011 P. 08
ONES
WWWAR"
OWE
Vm
EM
a
mom
MEN
•
•
1 HFPWQR*IH PAWI M
GRADATION IFST 1?1..SULIS
0T1:CHNIC'Al
Received Time Mar,29.10:45AM
0-�/29/2001 10:29 9709269089 A LKP ENGINEERING INC PAGE 08
MAY-24-1999 MON 12;34 PH HORTER AKER ARCHITECTS FAX NO, 9704"(60'(10 V. Uy
HepworthPawlak Geotech TEL:970-945-8454 May 24 99 10:28 No.01.1 P.09
C
t
r
twr Ruowi;S U-i. STANOA 10 solu h 1 AM WIAllf t101'1i M
FL>�l�
�r�.1=
i� j1�1[�lf�►r�f(yIR;I�il��t
_
WMENUMM
OEM
mid
`
t.rv�srt..rrrlllRi!>l�:.�b.
u
UTAM01 R AE PARTICLES IN M1LLIMf-TFR9 .
CLAY 79 03 FA CoONIf.•
GRAVEL 34 SAND 53 7. SR.T AND t.I AY 13 Y
I10111q L-IMI1 % PLASTICITY INULX 9
SAMPI I' Or", (`IUYny Gravelly Sand H?Om: Soling 10 of it rant
TW RC,�Dv7ry U,B. s,Ar.o1RD 9CtlIC6 rJ.CAR COl),1IC D `t11NC16
10
70
9
4tf
Vl
1
an w
70 Cl
n
eD
Oft
40
1111�11��
JAI
�AR
ME
z
11f
M
MIN
=MM01
r._�tta�tttttasRl.�
�
�
P
to
79
an 0
0D
00
06-
1)IAW11_I2 or PART1CI-FS IN MILL.IMCTI-i�,,
CLAY TQ ill l aotYs l'C
GRAVEL 3$ X SAW 51 X till I AND CLAY 11
LIQUID LIMIT x PLAS71CITY INl7FX 9
SAMPLL Ul : SlIoAly S11ty rrnveliy Sorid Hium. l3vtlllq I at 9 1 eel
IaE'PWORTH PAWLAK Firs. R
jA9 :iO4 Gi;(7�� ECHNIQAL, 1NC. CRADATi�N 'I'i,sl ICE ti1 1
Received Time Mar.29, 10:45AM
03/29/2001 10:29 9709269089 " LKP ENGINEERING INC PAGE 09
MAY-24-1999 MON 12:36 PM MORTER AKER ARCHITECTS FAX NU. y W41bU l lU r. 11
H.epworthPawlak Geotech TEL=970-945-8454 May 24 99 10-29 No.011 P.11
HIE=PWORTH-PAWLAK GEOTECHNICAL, INC.
TAB4 II
PERCOLATION TEST RESULTS JOB NO. 199 304
BOLE NO.
HOLE DEPTH
(INGHE8)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT VART OF
INTERVAL
11140H 1
WATER DEPTH
AT END OF
INTERVAL
{INCHES)
DROP IN
WA'TLR
LEVEL.
(I cwEs)
AVERAGE
PURCOLAI ION
RATE
(MIN,11INCH)
P.1
39
15
1 A
19 314
16
14 1/2
19
14 1/
14
12111
314
1 1 is
so
0 314
16 112 11
IS 1/Y
14 1t2 1/2
14 112
13 112 112
1112
P•Z
38
15
21
20 114
1934
187l4
19 114
6 114
1
77 314
ZO 1
314
80
19 V4 112
13 114 1
18'1/ a
79 114 1
Is 4
17 314 114
17 112 -114
P 3
39
15
15
12 112
9 1/2
a34
7314
11 14
61
12 1/2
2 11g
2e
Z_ n 1 1I7.
6 1/R i 1
8 314 3/4
73/4 1
7 114 .__ 1/2
8 12 3/4
8 V2
P-4
33
15
wil�r aduDd
walrr added
12
11 /4
6 1 4
10 117
7 112
1A
7 114
F,4314
8 114
3 rd/4
6
6 1 /4 3
2 112 2 314
11 Ix 3
4 3/4 2314
1 /4 2 314
4 314 112
2 114 2 112
Non. YOr00lP%iDll 10SVIlD Wail CorldUclod om I(�, 1I)VIL 'Ihq avoragr lulrcn}a8oll rota W,,LL 1>uod em iho Inn three readim* of aAeh 1081,
Received Time Mar•29. 10:45AM
ISDS Permit # 2_�� Date
ISDS Final Inspection
Wleteness Form
Tank is / d 2b gal . Tank Material
Tank is located L ft. and �Q degrees fron4.
ip.�.e� l�odsask)
Tank is located ft. and degrees from
(pes..aeac l.namark)
e
Tank set level. );:�PcD Tank lids within 8" of finished grade.
Size of field �'/'�7Z t2 3 2- units lineal ft.
Technology 7T, jr,7
:C S cleanout is installed in between tank and house(+ 1/100ft).
'r'23 There is a "T" that goes down 14 inches in the inlet and
outlet of the tank:
1e.5 Inlet . and outlet is sealed with tar• -,taper rubber gasket etc.
Tdrtk ;has two _dompartments with the.;=l'ar* . r-.-:cQ pagtment closest to the
house.
v
,maaure; distance and relative diregt..q to: ,f
Depth of field. � ft.
-" Soil interface raked.
Inspection portals at the .end of each trench..
Proper distance to setbacks.
Chambers properly installed as per manufacturers specifications.
(Chambers latched, end plates properly installed, rocks removed from
wrenches, etc.) S Q 3 g SOH,?
Type of pipe used for building sewer line leach field
Other
""-Inspection meets regnirPments.
Copy form to installer's file if recommendations for improvement were
suggested.
ACTION TAKEN:
V11
Setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch
Field -100 25 20 10 50 25 10 10
50 10 5 10 50 10 * 10
Bp ! .
JOB
EAGLE-- 0bWT$--ElF$: REALTH P.O. BOX 179 SHEET NO. OF
EAGLE, CO 81631 CALCULATED Bv 41. 0) DATE
CHECKED BY DATE
PRODUC7204-t )Single Sheets) 20S-I (Padded) /n�i®mc., Groton. Miss 01471. io Order PHONE TOLL FREE 1-800.225.6380
=I 2078-01 Tax #2107-044-01-002 '
NAM. Lot B2, Ute Forest WASTERVAL JOB NO. P/0 'S17�
1000 Ute Forest Lane, Edwards
JOB LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
G S Q
� 0 % 5' r / ©S.� l�
14 1" .' "O a Ir/f� 2 U ` � � � # l �
%� � � 5'-'� f%�� �c1!Q
I o2n - lm /o fez% iN r�'/%7� ed� 4�c C. 2� lei.' c� / oZa+ C•a 4C .
A �
(z 1?r
.J �,�J JQ �♦ =��,�"./
a/ � ✓ J �^/ % 2 /�
t9I � �X i S�, G> /iJ ��.X1J''a n� ^�r9 Q �t�,'
/PJ /� d c� rot f
✓a � �% Nb �a4�
/ G JOB COST SUMMARY
1 ^ h
e?1�3 r ° SAS ✓? d m ��-, r �,, t""/ ,
TOTAL SELLING PRICE
lo
Pe
JOB FOLDER Product 278
JOB FOLDER
,1030
N"; ,
\.\\ i f \\ j / fkD
0
^0
\ a / �O fi ri_Cil
Z
01Cil
ji
____ '` ` 't vat I •
_- — — - - - t \ � - t - - ,rye ptw� - ,1 ; • - K L. __ _ _ _ - J - - �. - _ _ tt
_ \ WER 4k r
'4�plAM BLDG SE til a ; O
Fr r�
10 AL TWO COMP. �\\H`;
\ 1 ��
1 O j CONC. SSRVC TANK w Q
— - DIAMETER SDR35 PVC �t�, \\t: tt 1LQ
~ - -
- _ CLEANOUT �, X. a` t n"?�` X`�
SERIAL D/STRIBU77ON µ T 'CL
\ \* vv a '�+ - fix" M� `\\ ,+r'\� C \\ , a e^. N��1- t - - _ _ _ O O
SEE DETAIL A -A /�a fir, r a e.\ �\ �\'+ y a �M F U��l \I ,- +' L O
� t _yy 1 t r,,
INSPECTION PORT c hr ` u
— `_ N 14.JI- J...- _�
STANQA_RD INF/L TRA TO _ •
lie
22
V� • \ \� m
Q�
1010
PERCOLA TION TEST RESULTS _
APPROX/ AT�LOCA7i01V\ \ \ \ �•
_PR�PosED wATL/NE \ \ \ \ Percolation and soil profile information from a report by HP Geotech, dated May 11, 1999. V ao
C14 0)
rZ
NA
toi
00
_ ` �_ ELECTRIC ` t \ \� QES/GN CAL COLA 170NS / 0)
TRANSFORMED \ \ \ \ \ 5 w 0 0
` Design percolation rate T = 31 minutes per inch U N
Number of bedrooms - 2
Maximum daily Flow = Qmax
0max = 2 bd ms x 2 persons/bdrm x 75 gallons/person/day x. 1507V • 3 0
GRAPHIC SCALE Qmax = 450 gpd ~ w
--- L
EDGE OF
PLOWED
ROAD
1000GALLON CONCRETE SEPTIC TANK_
BY COPLAND CONCRETE OR EQUIVALENT
TOP VIEW
---------- -----
i it I
I 1I t
II �
i II
L------------J L--------J
SIDE VIEW
4'.
90' ELBOW
22-1 /2 ' ELBOW
6' MINIMUM
DETAIL A - A
N. i.5.
L0
BASIS OF ELEVATION:
NE CNR, OF TRANS. PAD
ASSUMED ELEV., 1000'
(PER ARCHITECT)
GROUND SURFACE
90' ELBOW
INFILTRATOR CHAMBER
STANDARD AFIL TRA T OR
so .o so SEP FIC TANK o
I IL V = Qmax/24hrs x JO hrs
V = 56J gallons N rn
( IN FEET) Use 1000 gallon, two comportment precast. concrete tank by Copland Concrete (.0
equivalent - : (.01 inch = 20 ft )�' U x CV
i
ASSORP 77ON AREA _
m .-.
A=QmaxSxVT %©0 0 _
-v/Jl
Or
rn
A = 450155 x 501 3.4
�
Based on Applicatio Rate:
A = 450gpd/0.45 gpd/s. f.
\ A = 1000 s. f.
-2-4
Standard Infiltrator Chamber System in a trench configuration with on allowed 50 percent
reduction in the absorption area is recommended.
Acorrected = 500 s. f.
Surface area of one infiltrator Chamber = 15.5 s f. .
Use 32 Infiltrator Chambers in trenches as shown -on- the
plan.
_
NOTES:
1. Bends in the building sewer shall be limited to 45 d9grees.
2. The septic tank shall be installed level. The tank shad have removable covers or manholes to within-8
`
inches of the finished grade, for inspection and cleaning. _ . -
_ - �
`y,� ��`9 6,,,aA s.;�•. -
J. Excavate three (3) feet wide trenches. The horizontal distance from sidewall to side wall between the
' �'1ti/Z.Z2,00
trenches shall be a minimum of six (6) feet.��
4. The bottom and the sidewal/s of the trenches shall to raked to eliminate smearing.
5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers
- recommendations.,
e• Rockfill the sidewall area with native on -site soil for proper support.
7. Bac.«, the trenches with a minimum of 12 inches of tamped soil cover.
DRAYW. B ri L.P.
8. Avoid vhicle traffic over the system: -
CHECKED BY L.P.
9. All insh.,tions shall meet the rules and regulations of the Eagle County Environmental Health Division,
PROJECT NO.: 99108
Chapter 4, It -Yidua/ Sewage Disposal Systems.
10. The Septic =_ - - ,_
sfem Installation sholl be inspected by ;he Design Engineer prior to backf<lling. -
DATE.• �12=27-2000
DRAWNC NO.: 99108SOMA/N. D
NOTE. SITE PLAN BY MORTER AKER_ COLE ARCHITECTS
SHEET- _ ` ,t OF_1 -