2035 Cordillera Way #3, #4 - 210701402003 - 210701402004 - 0820IS
1
2
3
4
5
6
7
8
9
10
11
12
/ 12
HomeMy WebLinkAbout2035 Cordillera Way #3, #4 - 210701402003 - 210701402004 - 0820ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT Eagle County Department of Environmental Health PERMIT NS 0820 P.O. Box 850 - 550 Broadway Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM Owner: Kensington Land InyP-,tmant Telephone: Address:Rix 9RR �99 R1632 System Location: 49 Traverse Lot 36 Filing 2, Cordillera Subdi vi pion Licensed Installer: Chadwick Construrtinn Rnv A7 Mint,trn License Number: Conditional installation approval is hereby granted for the following: Minimum requirements:2-Gag_Gallon Septic Tank or Aerated Treatlnent unit Re Absorption area of dispersal area computed as follows: Q o�Percolation rater_ Inch in R . 1 Minutes Absorption area per bedroom Sq. Ft. Number of Bedrooms 7 X Sq. Ft. minimum requirement per bedroom - equals Total Sq. Ft. minimum requirement Special Requirements: Date: Noy- 12, 19R7 Environmental Health Officer: CONDITIONS: 1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the zoning and building departments shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to be licensed according to the regulations. FINAL APPROVAL OF SYSTEM: A�<.? �.61, /�c` G r 4C It "7 ��N�LI Ae—'- � No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the system is approved prior to covering any portion of the system. INSTALLED ABSORPTION OR DISPERSAL AREA: SQ. FT. INSTALLED SEPTIC TANK: 2 GALLONS; -f_ DEGREES � FEET f DESIGN ENGINEER OF SYSTEM: �4)m < <� 2c• r �� ��� INSTALLER OF SYSTEM:(Clf'�r� Slane �G�7S>51 SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR AERATED ACCESS PORTS ABOVE GRADE: YES O PROPER MATERIALS AND ASSEMBLY: YES NO COMPLIANCE WITH PERMIT REQUIREMENTS: YES NO COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: YES NO COMMENTS:.. i,L(•l (// d Lil� / C r'' C X cf. '5C,7 G ©i. l'f�v lLin/i�� %ire-E'c7�� r''<�4<•� (Any item checked NO requires correction before final approval of system zs made. Arrange a re-insp�ctzon when work is completed.) e� DATE 414nal Approval/ ENVIRONMENTAL HEALTH OFFICER: 92a 1e`- 1 DATE (Re-Inspection)-(*�ENVIRONMENTAL HEALTH OFFICER: 5 D RETAIN WITH RECEIPT RECORDS PERMIT Name of Applicant: Kensington band Investmentt—Name of Owner: Amount Paid: $150.00 Receipt Number: 41 RR Date:31 5 R7 Cashier: J. Brophy Check # 1172 ,l•1 s b vi �� s i 7 ��L�-t/1-A /), - n T S v�rn 7T CkvC'o �� e -h u� U r DvSi IvL / 4A11_ 11? ge errs White Ad Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner \Par 1CA7"' FORAL :ic'�:\(: DIc..SAL C 77^•.rT— 1 ENVIRC),"'ENTAL iiEALTii OFF:Ct- - EAGLE CVL'.:T`:' P.O. Ead ;350 Eagle, Coloro 51631 Colorado ::o. PER`iIT APPLICATION FEE' S150.00 328-7311 PF! C0L\T10'. 77S T F= �12Sr00 NAlfE OF 01%rNER: ��/� //7� /On C✓CA/�� /1Z/P 5 1�?ter/ ADDRESS: -�J< �+ �,/' �7 �CJ �V(tli7 r��� G'Q P�iO::E: - �'SliO NAME OF APPLICANT (if different frois owner): ADDRESS: PHONE: DESIGN ENGI::EER OF SYSTEM (if applicable) : �j7 �t��?.n �1in fir, ���"r/r7 t� ADDRESS: �7nsC 9%�i/�J/) mil? ��1� IU PHO::E: Prnavv I:,.:ii V�.JlUi 1. ivy: INSLALL:ITION OF SYSTE`i: �/ijl�Y,/�� �� � t :--/.fc. 7/�I r2 ` Licensed Installer (see attached list): YES- ><' NO ADDRESS: `%r' C X % /'/�i� 7/1, ✓� �C� Jam' %fin ��,5 PHONE: PER`1IT APPLICATION IS FOR: (New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SE'•IAGE DISPOSAL SYSTE4: Street/Rural Address: Lot Size: Legal Description: Lo 7-i�Z BUILDI.7G OR SERVICE TYPE (check apolicable cateaerv): ( ) Residential - Single Family ( ) Residential - Quad?lex Residential - Duplex( ) Co.--::::ercial (state usage)(' ) Residential - Tr-?lex NUMBER OF PERSONS: 3�3 Nrn[BER OF BEDR00:•1S : =� WASTE TYPES (check applicable cate^ories): ( ) Commercial or Institutional ( Dwellizb ( ) Non -Domestic Wastes ( ) Transient Use ( Garbage Disposal CX) Dishwasher Automatic Washer ( Spa Tub Other TYPE OF INDIVIDUAL S-L7-ACE DISPOSAL SYSTE:•i PROPOSED: Septic Tank ( ) Composting Toilet ( ) Incineration Toilet ( ) Vault Privy ( ) Greywater ( ) Chemical Toilet ( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Potable Use ( ) Other ( ) Recycling, Other Use WILL EFFLUENT BE DISCH.VRGED DIRECTL`i INTO T.'ATE?S OF THE STATE: YES ( ) NO IS SYSTEM DESIGNED FOR LESS T'dAN 2.000 GALLONS PER DAY* YES NO ( ) 14ASTE14ATER FLOW REDUCTION PLAN: YES ( ) NO (I S Yes, see attached cvas tewate•t S.Zccu tedUC tic;z Methods) NOTE: The FnvZ'Lo;une;Lta.r_' Heae-t;t 03' .icct mail «educe the .,Leotv.t`d ab.sc.Lp.ti.cn atea upon apptovaZ o5 an adequate, teastLzxa.tet 5Zcv, Aeduc.tLon SOURCE AND TYPE OF WATER SUPPLY: �_ kell ( ) Spring ( ) Creek/Stream Give depth of all wells within 200 feet of system: A'111 If supplied by community water, give name of supplier: �—rrll / SIGNATURE----�� ���---- / ��----- - - - - -- DATE- - - - INFORtfATION BELOW TO BE FILLED OUT BY ENVIRON.t(ENTAL HEALTH OFFICER: GROUND CONDITIONS: Petcent G.tou;id S.�ope r Depth .to Bedtoeh (pen 8' Puo'iee Hote) Depth .to Gtou;zc'Lcc,te,t Tab.-e SOIL PERCOLATION TEST RESULTS:. I{.c;tu,tcs pe•-..c;t6t in Ho,.e ? 1 4ic:ntLtcs pet inch to Ho.ee #2 I:u;twius 13e,-, i,LCjL tG ffo.Ce. #3 FINAL DISPOSAL BY: ( ) Abso.tptc o;l Trench, Bed o.t Pit ( ) Evapo.tta;tspiAci-ti.on ( ) Above Gtcu;id D.i.spnscL` ( ) Sand F.i,E'tct ( ) Unde,tg•tound DispnsaE ( ) Was-tctratct Pend Amowtt Paid: t (�7), (-)C) Receipt Ntunbc•t --4 1 g Date: --------------------CYN-l'-ii-%Z' --------------- - - - - - - NOTE: Site Plan must be attached to application. (Env. Health Department - Rev. 4-07-33) July 29, 1992 John Reed Cordillera Construction Box 988 Edwards CO, 81632 Re: Duplexes located on Lot 36, Cordillera Subdivision Filing No. 2, Duplex units 3 & 4. Dear John, Based on our discussion from July 22, it is my understanding that you propose to add one bedroom to unit three. This would bring the total number of bedrooms on the septic system to seven. As we discussed on July 29, the septic system for units 3 and 4 has sufficient capacity to add a total of one bedroom the existing system. When you apply for the building permit, enclose a copy of this letter to expedite Environmental Health approval. Please call me if you have any question. Sincerely, Roger Boyd Assistant Environmental Health Officer cc ISDS Permit file 820 I TEM NO. RE, 'ARKS CORRECTED BY ,L Vie -% Nq ` G t 1"� � \ �(� mac' �� i-yGG- �� � .��'�G 1• �`i Cj t C 1/0 X/c, (--7�119,/ s U' INSPECTED BY: NAME RECEIVED BY: NAME TITLE TITLE KrAlpter-Mountain Engineeringu& PERCOLATION TEST RESULTS AND SEPTIC RECOMMENDATIONS FOR HOUSE 3 & HOUSE 4 LOT 36, CORDILLERA SUBDIVISION FILING NO. 2 EAGLE COUNTY, COLORADO PREPARED FOR: KENSINGTON LAND INVESTMENT PARTNERS PROJECT NO. V-7142E OCTOBER 1987 Box No. 978 1420 Vance Street Avon, Colorado 81620 Lakewood, Colorado 80215 949-5072 Denver 893-1 531 Phone: 232-01 58 SCOPE This report presents the results of percolation tests and provides septic system recommendations for the proposed House 3 and House 4 at Lot 36, Cordillera Subdivision Filing No. 2, Eagle County, Colorado. SITE INVESTIGATION The site was investigated on October 25, 1987, and eight percolation test holes were dug to a minimum depth of 30 inches. Holes were presoaked and percolation tests performed on October 26, 1987. Results of these tests are included in this report; see PERCOLATION TEST RESULTS. Also, a test pit was excavated to a depth of 10 feet on October 22, 1987, with a conventional backhoe. A summary of the test pit log is also a part of this report; see Figure No. 1. Locations of the percolation test holes and the test pit are shown on Drawing No.. 1. SITE LOCATION AND DESCRIPTION The site is located in a part of Lot:36, Cordillera Subdi- vision Filing No. 2, and Tract G, Cordillera Subdivision Filing No. 2. The site is generally sloping to the south, and vege- tation consists of sage brush. SUBSURFACE AND GROUNDWATER CONDITIONS Subsurface conditions in the proposed leach field area are uniform, and consist of topsoil to a depth of 9 feet, under- lain by very weathered bedrock. Refer to Figure No. 1 for additional information. 2 PERCOLATION TEST RESULTS A total of eight percolation tests were performed on the site as specified by the Eagle County Individual Sewage Disposal System Regulations. Results were as follows: Test Hole Min/1" Drop Date of Test Ambient Air Temp 1 7.5 10/21/87 50 2 7.1 10/21/87 50 3 8.0 10/21/87 50 4 10.9 10/21/87 50 5 0 10/21/87 50 6 8.0 10/21/87 50 7 7.1 10/21/87 50 8 8.0 10/21/87 50 Average time for 1" drop: 8.1 min. DESIGN CRITERIA A duplex residence has been proposed for this site. The duplex will have a total of seven bedrooms and will be equipped with a garbage disposed and automatic washing machine. Thus design criteria for calculations are: 2 persons/bedroom 75 gallons/person/day - average flow +20% absorption area for garbage disposal +40% absorption area for automatic washer -25% absorption area for dosing tank Maximum flow: 150% of average flow 3 CALCULATIONS A = �T where A = minimum absorption area (sq.ft.) Q = maximum quantity of sewage flow (gal/day) T = percolation rate (min/inch) Q = 1575 gallons/day 1575-Y8 A= —5-- = 891 sq, ft. +178 sq. ft. (disposal - +20%) +356 sq. ft. (washer - +40% -223 sq. ft. (dosing - -25%l 1,203 sq. ft. absorption trench If ABS-SB2 (or equal) system is used, 1 l.f. of SB2 is required for 3 s.f. absorption trench; thus 400 l.f. needed. From Table 4 (Section 7.1.a of the Eagle County Regulations), a 2000 gallon septic tank is needed for seven bedrooms. Dosing tank: Average flow = 7 x 20 x 75 = 1050 gal/day Peak flow = 1.5 x 1050 = 1575 gal/day Size dosing tank for 3 cycles/day for average flow: 1050/3 = 350 gallons SEPTIC SYSTEM RECOMMENDATIONS Based on the preceding calculations,�it is recommended to install a 2000 gallon compartmented septic tank followed by a minimum 1200 square foot seepage bed. An inspection of the system should be made by a representative of the Eagle County Environ- mental Health Department prior to backfilling. The installation and material specifications must comply with the Eagle County Individual Sewage Disposal System Regulations. As an alternate to the standard 1200 square foot seepage bed, 400 lineal feet of 10-inch diameter "gravel -less" leach bed tubing (as manufactured by American Drainage Systems, Inc., or equal) could be embedded in the native soils of the site. 4 SEPTIC SYSTEM RECOMMENDATIONS - continued Due to the remoteness of the site, this alternate would probably be cost effective. A dosing chamber is to be installed at this site. The dosing chamber will allow for periodic high rate discharge to fill the drainage field instead of a slow trickle into the field. This will prolong the life of the drainage field. CONCLUSIONS This report has been prepared for the exclusive use of Kensington Land Investment Partners for the specific application to the proposed duplex site at Lot 36, Cordillera Subdivision Filing No. 2, Eagle County, Colorado. The findings and recommendations of this report have been obtained in accordance with accepted professional engineering practices. There is no other warranty, either expressed or implied. If we can be of further assistance, please do not hesitate to calla Sincerely, INTER -MOUNTAIN ENGINEERING, LTD. � � 2793P.E. - � 2 = �=G Thomas Allen, P E oljjProject Engineer TEST PIT NO. 1 v t�! DEPTH / � �i.� IN FEET " DESCRIPTION OF MATERIAL. REMARKS 0 TOPSOIL I i 5 VERY WEATHERED SILTSTONE 10 BEDROCK Bottom of Excavation 10' No groundwater encountered. 15 SUMMARY OF TEST PITS . PROPOSED DUPLEX LOT 36, CORDILLERA SUBDIVISION FILING NO. 2 EAGLE COUNTY, COLORADO PROJECT Nay V _ 714 2 E ' FIGURE NO. - 1 JOB NAME, 4�4 ,SOB IVO, -6�1,,.- JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED ..a.� t �. r •_ '� ''� HU .��►" Az ,4 f ✓ r 1 t NET PROFIT JOB FOLDER Product. 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER Printed in U,S.A SOIL SLOPE y4`%FOOT MIN. UNTREATED BUILDING PAPER .y r '+! r, "`. 10" Min. OR 2 HAY OR STRAW 3' Max. %2 TO 2V GRAVEL —� 2" Min. ------------ . ' . 7Min. 4"0 PERFORATED SECTION A -A STANDARD ABSORSTION TRENCH NO SCALE IOO FT MAX. FROM SLOPE—�,4' MAX. DISTRIBUTION BOX %2 " TO 21't' GRAVEL UNTREATED BUILDING PAPER OR 2 HAY OR STRAW SECTION C-C STANDARD ABSORBTION TRENCH NO SCALE UG 2 I -- SLOPE /4"%FOOT MIN 16 Min. SOIL 18" to (FROM TRENCH j— 24" EXCAVATION) FREE FROM LUMPS I CLODS, OR ROCKS 4 OR LARGER IN DIAMETER " 10" GRAVEL -LESS DISTRIBUTION PIPE MAX. SLOPE I V 100 ALTERNATE SECTION A -A TRENCH CROSS- SECTION WITH GRAVEL -LESS DISTRIBU- TION PIPE NO SCALE EXPOSE INSPECTION PORT 1,SEE DETAIL D 10" Min 3' Max. _�— 2" Min. 6" Min �4� j6 PERFORATED PVC. PIPE ADD RISER PIPE AS NECESSARY TO EXPOSE PLUG IN �O O O O o O O 4" PERFORATED PIPE 11 OR 10" GRAVEL -LESS DI-STRIBUTION PIPE DETAIL D INSPECTION / CLEANOUT PORT NO SCALE X I "DROP I 0_ 1 L—:)pX DETAIL E DISTRIBUTION BOX NO SCALE 0000 ' VE E PIPES MUST UST H�vE EQUAL INVERT ELEVATIONS AT CUTLET SECTION X -X NO SCALE I SCALE: I = 40 J AV we 8 Min. 8 Min. 8 Min. \ k f 1 f ' rf� 0y �\ 2Qp�Q�29�IE���1k���`' 10 'Min. 3 Mox. Typ. 4t 4 / S 10 • T O t -- • S� ROAD JEEP (TO BE ABANDONED) 11 2000 GALLON SEPTIC TANK I' �D qD - .S' 1 0 C)• SECTION B-BJT S t f x f V NO SCALE NOTES: 1. Building sewer line to septic tank shall have a minimum slo of 1/4" per foot. Bends in building sewer shall be limited io G1 45 degrees. O� 2. Septic tank shall be installed level. Tank to have removabli cover or manholes extended to within 8 inches of finish grade for iccess J to each compartment, for cleaning and inspection. Septic t k to _ ; ,�~ 0.00 -1 meet all the requirements of Eagle Count Individual Sewage is osal - a '24"P _: 017 O R= i3 q 9 Y 9 p � � FF 4� __ Systems, Section 4.07. l 0.00 3. A dosing tank shall be installed as noted on the drawings.- 4. A distribution box shall be installed as noted on the drawii s. 5. Absorption trenches shall not exceed 100 feet in length. A iinimum O / distance of 8 feet shall be provided between trenches. Max um depth g S of trenches shall be 3 feet`. Disposal pipe shall be 4 inch lerforated BO P.V.C. pipe. Maximum grade of pipe shall not exceed 4 inch rop in CJL EVARp WO feet. Disposal pipe to be surrounded by clean gravel. ravel may range in size from 1/2 inch to 2-1/2 inches. Gravel sh 1 extend from at least 2 inches above the top of the distribution pili to at least 6 inches below the bottom of the pipe. The top of th gravel shall be covered with untreated building paper or a 2-inch yer of straw or hay. A minimum of 10 inches of soil suitable fa vege- tation shall be placed from the top of the straw to the fin hed surface grade. The final cover shall be graded to deflect r noff water away from the disposal area. Machine compaction off al cover shall not be permitted. Absorption trenches shall be eeded as soon as possible to prevent soil erosion due to rainfall 6. Large diameter, gravel -less leach bed tubing such as Advanc Drainage Systems, Inc., 10-inch SB2 or equal, may be substituted in le absorption trenches. Follow manufacturer's recommendations or installation of gravel -less leach bed tubing. 7. All installations shall meet the rules and regulations of E le County Health Department as set forth in the Individual Sew e Disposal System Regulations of that department. Constructi of the system shall be inspected by Eagle County. 8070 p BOX i78 SUITE 103 Mr `ADkEngineeringLtd. er-Mountain 1420 V ANCE STREET a �4 1ft�C • • L.AKEWOOD, COLD. B0215 (303) 232-0158 ❑ee: ;; -..aa Hv.. Project No. G. T. A. SEPTIC SYSTEM DESIGN V - 7142 E onto issue a: — --- --- - ----- --- -- ----- .._—_—__..- --- K M. J. 1114187 DUPLEX 3 AND 4, � i7re c.k as ey. Sce Le: J. M. S. LOT 36, CORDILLERA FILING NO. 2 1 "= 4o' —!- __ ___----------------�_�-- -k - EAGLE COUNTY, COLORA D O sn.. t No . 1 OF 1