HomeMy WebLinkAbout2035 Cordillera Way #3, #4 - 210701402003 - 210701402004 - 0820ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
Eagle County Department of Environmental Health PERMIT NS 0820
P.O. Box 850 - 550 Broadway
Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823
YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE
BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM
Owner: Kensington Land InyP-,tmant Telephone:
Address:Rix 9RR �99 R1632
System Location: 49 Traverse Lot 36 Filing 2, Cordillera Subdi vi pion
Licensed Installer: Chadwick Construrtinn Rnv A7 Mint,trn License Number:
Conditional installation approval is hereby granted for the following:
Minimum requirements:2-Gag_Gallon Septic Tank or Aerated Treatlnent unit
Re Absorption area of dispersal area computed as follows: Q
o�Percolation rater_ Inch in R . 1 Minutes
Absorption area per bedroom Sq. Ft.
Number of Bedrooms 7 X Sq. Ft. minimum requirement per bedroom -
equals Total Sq. Ft. minimum requirement
Special Requirements:
Date: Noy- 12, 19R7 Environmental Health Officer:
CONDITIONS:
1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System
Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building
requirements. Connection to or use with any dwelling or structure not approved by the zoning and building
departments shall automatically be a violation of a requirement of the permit and cause for both legal action and
revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to
be licensed according to the regulations.
FINAL APPROVAL OF SYSTEM: A�<.? �.61, /�c` G r 4C It "7 ��N�LI Ae—'- �
No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System
Regulations until the system is approved prior to covering any portion of the system.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQ. FT.
INSTALLED SEPTIC TANK: 2 GALLONS; -f_ DEGREES � FEET
f
DESIGN ENGINEER OF SYSTEM: �4)m < <� 2c• r �� ���
INSTALLER OF SYSTEM:(Clf'�r� Slane �G�7S>51
SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR
AERATED ACCESS PORTS ABOVE GRADE: YES O
PROPER MATERIALS AND ASSEMBLY: YES NO
COMPLIANCE WITH PERMIT REQUIREMENTS: YES NO
COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: YES NO
COMMENTS:..
i,L(•l (// d Lil� / C r'' C X cf. '5C,7 G
©i. l'f�v lLin/i�� %ire-E'c7�� r''<�4<•�
(Any item checked NO requires correction before final approval of system zs made. Arrange a re-insp�ctzon when
work is completed.) e�
DATE 414nal Approval/ ENVIRONMENTAL HEALTH OFFICER: 92a 1e`- 1
DATE (Re-Inspection)-(*�ENVIRONMENTAL HEALTH OFFICER: 5 D
RETAIN WITH RECEIPT RECORDS PERMIT
Name of Applicant: Kensington band Investmentt—Name of Owner:
Amount Paid: $150.00 Receipt Number: 41 RR Date:31 5 R7 Cashier: J. Brophy
Check # 1172
,l•1 s b vi �� s i 7 ��L�-t/1-A /), -
n T S v�rn 7T
CkvC'o �� e -h u� U r DvSi IvL / 4A11_ 11? ge errs
White Ad Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner
\Par 1CA7"' FORAL :ic'�:\(: DIc..SAL C 77^•.rT—
1
ENVIRC),"'ENTAL iiEALTii OFF:Ct- - EAGLE
CVL'.:T`:'
P.O. Ead ;350
Eagle, Coloro 51631
Colorado
::o.
PER`iIT APPLICATION
FEE' S150.00 328-7311
PF! C0L\T10'. 77S T F=
�12Sr00
NAlfE OF 01%rNER:
��/� //7� /On C✓CA/�� /1Z/P 5 1�?ter/
ADDRESS: -�J<
�+ �,/' �7
�CJ �V(tli7 r��� G'Q
P�iO::E:
-
�'SliO
NAME OF APPLICANT
(if different frois owner):
ADDRESS:
PHONE:
DESIGN ENGI::EER OF
SYSTEM (if applicable) : �j7 �t��?.n
�1in
fir, ���"r/r7 t�
ADDRESS:
�7nsC 9%�i/�J/) mil? ��1� IU PHO::E:
Prnavv I:,.:ii V�.JlUi 1.
ivy: INSLALL:ITION OF SYSTE`i: �/ijl�Y,/��
��
� t :--/.fc. 7/�I r2
` Licensed Installer
(see attached list): YES- ><'
NO
ADDRESS: `%r' C X
% /'/�i� 7/1, ✓� �C� Jam' %fin ��,5
PHONE:
PER`1IT APPLICATION IS FOR: (New Installation ( ) Alteration ( ) Repair
LOCATION OF PROPOSED INDIVIDUAL SE'•IAGE DISPOSAL SYSTE4:
Street/Rural Address:
Lot Size:
Legal Description: Lo 7-i�Z
BUILDI.7G OR SERVICE TYPE (check apolicable cateaerv):
( ) Residential - Single Family ( ) Residential - Quad?lex
Residential - Duplex( ) Co.--::::ercial (state usage)(' ) Residential - Tr-?lex
NUMBER OF PERSONS: 3�3 Nrn[BER OF BEDR00:•1S : =�
WASTE TYPES (check applicable cate^ories):
( )
Commercial or Institutional
(
Dwellizb
( )
Non -Domestic Wastes
( )
Transient Use
(
Garbage Disposal
CX)
Dishwasher
Automatic Washer
(
Spa Tub
Other
TYPE OF INDIVIDUAL S-L7-ACE DISPOSAL SYSTE:•i PROPOSED:
Septic Tank
(
)
Composting Toilet
( )
Incineration Toilet
( )
Vault Privy
(
)
Greywater
( )
Chemical Toilet
( )
Pit Privy
(
)
Aeration Plant
( )
Recycling, Potable Use
( )
Other
( )
Recycling, Other Use
WILL EFFLUENT BE DISCH.VRGED
DIRECTL`i INTO T.'ATE?S OF THE
STATE:
YES ( ) NO
IS SYSTEM
DESIGNED FOR
LESS
T'dAN
2.000 GALLONS PER DAY*
YES NO ( )
14ASTE14ATER FLOW REDUCTION PLAN: YES ( ) NO
(I S Yes, see attached cvas tewate•t S.Zccu tedUC tic;z Methods)
NOTE: The FnvZ'Lo;une;Lta.r_' Heae-t;t 03' .icct mail «educe the .,Leotv.t`d ab.sc.Lp.ti.cn atea upon
apptovaZ o5 an adequate, teastLzxa.tet 5Zcv, Aeduc.tLon
SOURCE AND TYPE OF WATER SUPPLY: �_ kell ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system: A'111
If supplied by community water, give name of supplier: �—rrll
/
SIGNATURE----�� ���---- / ��----- - - - - -- DATE-
- - -
INFORtfATION BELOW TO BE FILLED OUT BY ENVIRON.t(ENTAL HEALTH OFFICER:
GROUND CONDITIONS: Petcent G.tou;id S.�ope
r Depth .to Bedtoeh (pen 8' Puo'iee Hote)
Depth .to Gtou;zc'Lcc,te,t Tab.-e
SOIL PERCOLATION TEST RESULTS:. I{.c;tu,tcs pe•-..c;t6t in Ho,.e ? 1
4ic:ntLtcs pet inch to Ho.ee #2
I:u;twius 13e,-, i,LCjL tG ffo.Ce. #3
FINAL DISPOSAL BY:
( ) Abso.tptc o;l Trench, Bed o.t Pit ( ) Evapo.tta;tspiAci-ti.on
( ) Above Gtcu;id D.i.spnscL` ( ) Sand F.i,E'tct
( ) Unde,tg•tound DispnsaE ( ) Was-tctratct Pend
Amowtt Paid: t (�7), (-)C) Receipt Ntunbc•t --4 1 g Date:
--------------------CYN-l'-ii-%Z' --------------- - - - - - -
NOTE: Site Plan must be attached to application.
(Env. Health Department - Rev. 4-07-33)
July 29, 1992
John Reed
Cordillera Construction
Box 988
Edwards CO, 81632
Re: Duplexes located on Lot 36, Cordillera Subdivision
Filing No. 2, Duplex units 3 & 4.
Dear John,
Based on our discussion from July 22, it is my understanding that
you propose to add one bedroom to unit three. This would bring
the total number of bedrooms on the septic system to seven. As
we discussed on July 29, the septic system for units 3 and 4 has
sufficient capacity to add a total of one bedroom the existing
system. When you apply for the building permit, enclose a copy
of this letter to expedite Environmental Health approval. Please
call me if you have any question.
Sincerely,
Roger Boyd
Assistant Environmental Health Officer
cc ISDS Permit file 820
I TEM
NO.
RE, 'ARKS
CORRECTED
BY
,L
Vie
-%
Nq
` G
t 1"� � \ �(� mac' �� i-yGG- �� � .��'�G 1• �`i
Cj
t
C 1/0
X/c, (--7�119,/
s
U'
INSPECTED BY: NAME RECEIVED BY: NAME
TITLE TITLE
KrAlpter-Mountain
Engineeringu&
PERCOLATION TEST RESULTS
AND SEPTIC RECOMMENDATIONS
FOR
HOUSE 3 & HOUSE 4
LOT 36, CORDILLERA SUBDIVISION FILING NO. 2
EAGLE COUNTY, COLORADO
PREPARED FOR:
KENSINGTON LAND INVESTMENT PARTNERS
PROJECT NO. V-7142E
OCTOBER 1987
Box No. 978 1420 Vance Street
Avon, Colorado 81620 Lakewood, Colorado 80215
949-5072 Denver 893-1 531 Phone: 232-01 58
SCOPE
This report presents the results of percolation tests
and provides septic system recommendations for the proposed
House 3 and House 4 at Lot 36, Cordillera Subdivision Filing
No. 2, Eagle County, Colorado.
SITE INVESTIGATION
The site was investigated on October 25, 1987, and eight
percolation test holes were dug to a minimum depth of 30 inches.
Holes were presoaked and percolation tests performed on October 26,
1987. Results of these tests are included in this report; see
PERCOLATION TEST RESULTS. Also, a test pit was excavated to a
depth of 10 feet on October 22, 1987, with a conventional
backhoe. A summary of the test pit log is also a part of this
report; see Figure No. 1. Locations of the percolation test
holes and the test pit are shown on Drawing No.. 1.
SITE LOCATION AND DESCRIPTION
The site is located in a part of Lot:36, Cordillera Subdi-
vision Filing No. 2, and Tract G, Cordillera Subdivision Filing
No. 2. The site is generally sloping to the south, and vege-
tation consists of sage brush.
SUBSURFACE AND GROUNDWATER CONDITIONS
Subsurface conditions in the proposed leach field area
are uniform, and consist of topsoil to a depth of 9 feet, under-
lain by very weathered bedrock. Refer to Figure No. 1 for
additional information.
2
PERCOLATION TEST RESULTS
A total of eight percolation tests were performed on the
site as specified by the Eagle County Individual Sewage Disposal
System Regulations. Results were as follows:
Test Hole
Min/1" Drop
Date of Test
Ambient Air Temp
1
7.5
10/21/87
50
2
7.1
10/21/87
50
3
8.0
10/21/87
50
4
10.9
10/21/87
50
5
0
10/21/87
50
6
8.0
10/21/87
50
7
7.1
10/21/87
50
8
8.0
10/21/87
50
Average
time for 1" drop:
8.1 min.
DESIGN CRITERIA
A duplex residence has been proposed for this site. The
duplex will have a total of seven bedrooms and will be equipped
with a garbage disposed and automatic washing machine. Thus
design criteria for calculations are:
2 persons/bedroom
75 gallons/person/day - average flow
+20% absorption area for garbage disposal
+40% absorption area for automatic washer
-25% absorption area for dosing tank
Maximum flow: 150% of average flow
3
CALCULATIONS
A = �T where A = minimum absorption area (sq.ft.)
Q = maximum quantity of sewage flow (gal/day)
T = percolation rate (min/inch)
Q = 1575 gallons/day
1575-Y8
A= —5-- = 891 sq, ft.
+178 sq. ft. (disposal - +20%)
+356 sq. ft. (washer - +40%
-223 sq. ft. (dosing - -25%l
1,203 sq. ft. absorption trench
If ABS-SB2 (or equal) system is used, 1 l.f. of SB2 is
required for 3 s.f. absorption trench; thus 400 l.f. needed.
From Table 4 (Section 7.1.a of the Eagle County Regulations),
a 2000 gallon septic tank is needed for seven bedrooms.
Dosing tank:
Average flow = 7 x 20 x 75 = 1050 gal/day
Peak flow = 1.5 x 1050 = 1575 gal/day
Size dosing tank for 3 cycles/day for average flow:
1050/3 = 350 gallons
SEPTIC SYSTEM RECOMMENDATIONS
Based on the preceding calculations,�it is recommended to
install a 2000 gallon compartmented septic tank followed by a
minimum 1200 square foot seepage bed. An inspection of the system
should be made by a representative of the Eagle County Environ-
mental Health Department prior to backfilling. The installation
and material specifications must comply with the Eagle County
Individual Sewage Disposal System Regulations.
As an alternate to the standard 1200 square foot seepage
bed, 400 lineal feet of 10-inch diameter "gravel -less" leach
bed tubing (as manufactured by American Drainage Systems, Inc.,
or equal) could be embedded in the native soils of the site.
4
SEPTIC SYSTEM RECOMMENDATIONS - continued
Due to the remoteness of the site, this alternate would probably
be cost effective.
A dosing chamber is to be installed at this site. The
dosing chamber will allow for periodic high rate discharge to
fill the drainage field instead of a slow trickle into the field.
This will prolong the life of the drainage field.
CONCLUSIONS
This report has been prepared for the exclusive use of
Kensington Land Investment Partners for the specific application
to the proposed duplex site at Lot 36, Cordillera Subdivision
Filing No. 2, Eagle County, Colorado.
The findings and recommendations of this report have been
obtained in accordance with accepted professional engineering
practices. There is no other warranty, either expressed or
implied.
If we can be of further assistance, please do not hesitate
to calla
Sincerely,
INTER -MOUNTAIN ENGINEERING, LTD.
� � 2793P.E.
- � 2 = �=G
Thomas Allen, P E
oljjProject
Engineer
TEST PIT NO. 1
v
t�!
DEPTH / � �i.�
IN FEET " DESCRIPTION OF MATERIAL. REMARKS
0
TOPSOIL
I
i
5
VERY WEATHERED SILTSTONE
10 BEDROCK
Bottom of Excavation 10' No groundwater
encountered.
15
SUMMARY OF TEST PITS .
PROPOSED DUPLEX
LOT 36, CORDILLERA SUBDIVISION FILING NO. 2
EAGLE COUNTY, COLORADO
PROJECT Nay V _ 714 2 E
' FIGURE NO. - 1
JOB NAME,
4�4 ,SOB IVO, -6�1,,.-
JOB LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
..a.�
t �.
r
•_ '�
''�
HU
.��►"
Az
,4 f ✓
r
1 t
NET PROFIT
JOB FOLDER Product. 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471
JOB FOLDER
Printed in U,S.A
SOIL SLOPE y4`%FOOT MIN.
UNTREATED BUILDING PAPER .y r '+! r, "`. 10" Min.
OR 2 HAY OR STRAW
3' Max.
%2 TO 2V GRAVEL —� 2" Min.
------------
. ' . 7Min.
4"0 PERFORATED
SECTION A -A
STANDARD ABSORSTION
TRENCH
NO SCALE
IOO FT MAX.
FROM SLOPE—�,4' MAX.
DISTRIBUTION
BOX
%2 " TO 21't' GRAVEL
UNTREATED BUILDING PAPER
OR 2 HAY OR STRAW
SECTION C-C
STANDARD ABSORBTION
TRENCH
NO SCALE
UG
2
I --
SLOPE /4"%FOOT MIN
16 Min.
SOIL 18" to
(FROM TRENCH j— 24"
EXCAVATION)
FREE FROM LUMPS
I
CLODS, OR ROCKS 4
OR LARGER IN DIAMETER "
10" GRAVEL -LESS
DISTRIBUTION PIPE
MAX. SLOPE I V 100
ALTERNATE
SECTION A -A
TRENCH CROSS- SECTION
WITH GRAVEL -LESS DISTRIBU-
TION PIPE
NO SCALE
EXPOSE INSPECTION PORT
1,SEE DETAIL D
10" Min
3' Max.
_�— 2" Min.
6" Min
�4� j6 PERFORATED
PVC. PIPE
ADD RISER PIPE AS
NECESSARY TO EXPOSE PLUG
IN
�O O O O o O O
4" PERFORATED PIPE 11
OR 10" GRAVEL -LESS
DI-STRIBUTION PIPE
DETAIL D
INSPECTION / CLEANOUT PORT
NO SCALE
X
I "DROP I 0_ 1
L—:)pX
DETAIL E
DISTRIBUTION BOX
NO SCALE
0000 ' VE E PIPES
MUST UST H�vE EQUAL
INVERT ELEVATIONS
AT CUTLET
SECTION X -X
NO SCALE
I
SCALE: I = 40
J AV
we
8 Min. 8 Min. 8 Min. \ k f 1
f ' rf�
0y
�\ 2Qp�Q�29�IE���1k���`'
10 'Min. 3 Mox. Typ. 4t 4 / S 10
• T O t
--
• S�
ROAD
JEEP
(TO BE ABANDONED)
11 2000 GALLON
SEPTIC TANK I' �D
qD -
.S' 1 0 C)•
SECTION B-BJT
S t f x f V
NO SCALE
NOTES:
1. Building sewer line to septic tank shall have a minimum slo
of 1/4" per foot. Bends in building sewer shall be limited io G1
45 degrees. O�
2. Septic tank shall be installed level. Tank to have removabli cover
or manholes extended to within 8 inches of finish grade for iccess
J
to each compartment, for cleaning and inspection. Septic t k to _ ; ,�~ 0.00 -1
meet all the requirements of Eagle Count Individual Sewage is osal - a '24"P _: 017 O R= i3
q 9 Y 9 p � � FF 4� __
Systems, Section 4.07. l 0.00
3. A dosing tank shall be installed as noted on the drawings.-
4. A distribution box shall be installed as noted on the drawii s.
5. Absorption trenches shall not exceed 100 feet in length. A iinimum O /
distance of 8 feet shall be provided between trenches. Max um depth g S
of trenches shall be 3 feet`. Disposal pipe shall be 4 inch lerforated BO
P.V.C. pipe. Maximum grade of pipe shall not exceed 4 inch rop in
CJL EVARp
WO feet. Disposal pipe to be surrounded by clean gravel. ravel
may range in size from 1/2 inch to 2-1/2 inches. Gravel sh 1 extend
from at least 2 inches above the top of the distribution pili to at
least 6 inches below the bottom of the pipe. The top of th gravel
shall be covered with untreated building paper or a 2-inch yer
of straw or hay. A minimum of 10 inches of soil suitable fa vege-
tation shall be placed from the top of the straw to the fin hed
surface grade. The final cover shall be graded to deflect r noff
water away from the disposal area. Machine compaction off al
cover shall not be permitted. Absorption trenches shall be eeded
as soon as possible to prevent soil erosion due to rainfall
6. Large diameter, gravel -less leach bed tubing such as Advanc Drainage
Systems, Inc., 10-inch SB2 or equal, may be substituted in le
absorption trenches. Follow manufacturer's recommendations or
installation of gravel -less leach bed tubing.
7. All installations shall meet the rules and regulations of E le
County Health Department as set forth in the Individual Sew e
Disposal System Regulations of that department. Constructi of the
system shall be inspected by Eagle County.
8070
p BOX i78 SUITE 103
Mr `ADkEngineeringLtd.
er-Mountain 1420 V ANCE STREET
a �4 1ft�C • • L.AKEWOOD, COLD. B0215
(303) 232-0158
❑ee: ;; -..aa Hv.. Project No.
G. T. A. SEPTIC SYSTEM DESIGN V - 7142 E
onto issue a:
— --- --- - ----- --- -- ----- .._—_—__..- --- K M. J. 1114187
DUPLEX 3 AND 4,
� i7re c.k as ey. Sce Le:
J. M. S. LOT 36, CORDILLERA FILING NO. 2 1 "= 4o'
—!- __ ___----------------�_�-- -k - EAGLE COUNTY, COLORA D O sn.. t No .
1 OF 1