HomeMy WebLinkAbout2966 E Lake Creek Rd - 210518401002 - 0802ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT Eagle County Department of Environmental Health PERMIT N2 0802 P.O. Box 850 - 550 Broadway Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM Owner: Monroe Property Company Telephone: (312) 407-6740 Address: 200 West Madison, Chicago, ILL 60606 System Location: 2966 E. Lake Creek Road - Edwards Licensed Installer: f, i License Number: Conditional installation approval is hereby granted for the following: 5 ,/ o 'l 1pxq, j Minimum requirements s�_ C Gallon Septic TanlFor Aerated Treatment unit Absorption area of dispersal area computed as follows: Percolation rate:_1_ Inch in 10 Minutes Absorption area per bedroom Sq. Ft. Number of Bedrooms X Sq. Ft. minimum requirement per bedroom - equals Total Sq. Ft. minimum requirement Special Requirements: 111E SLpriC 4ow k sEgwyc, �'!� ' " %4KE,�5 U10%T SVO'Lle o C-losee In eypir bur s�-y' A6,*, fhc coell Date: �- % c� Environmental Health Officer: CONDITIONS: 1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the zoning and building departments shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to be licensed according to the regulations. FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the system is approved prior to covering any portion of the system. I// INSTALLED ABSORPTION OR DISPERSAL AREA: 1 � SQ. FT. 'S5'. r" INSTALLED SEPTIC TANK: L C' - 0C GALLONS; � DEGREES; FEET DESIGN ENGINEER OF SYSTEM: ��i.v /�i �� r, �4ss��,., '� �i' 6C. INSTALLER OF SYSTEM: '�-�f'-� PHONE: SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR AERATED ACCESS PORTS ABOVE GRADE: YESX,_ NO PROPER MATERIALS AND ASSEMBLY: YES X NO COMPLIANCE WITH PERMIT REQUIREMENTS: YES NO COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: YES NO COMMENTS: �� �✓ �.. ��.2ri► 33) 3 (Any item checked NO requires correction before final approval of system is made. Arrange a re -inspection when work is completed.) ) __ � 7 ,. DATE (Final Approval)/ ENVIRONMENTAL HEALTH OFFICER: DATE (Re -Inspection) ENVIRONMENTAL HEALTH OFFICER: RETAIN WITH RECEIPT RECORDS PERMIT i Name of Applicant: �Y� LCEr fe_ n'S� 4 ,) Name of Owner: o XY`�--- w1,3q9(0 p ��� �i-, r Amount Paid: ` s Receipt Number: 3 Date.n � -� -n c Cashier:A._-P'n tZ White and Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner AP?r r, 7CI \L ';F'�AGF D T`.. q.*,I. . . __`. P77..,T7 iiEALTH OFF :CE - EAGLE- COUNT: 16. P.O. wN 350 Eagle, Colorado 81631 No. PER -MIT AP?- LICATTO`: FEE: S150.00 328-7311 PF7.00L.\T10N TEST F=7: 50.nr) NAME OF OVN ER: Monroe Property Company ADDRESS: 200 West Madison, Chicago, Ill 60606 NAME OF UPLIC:\.`IT (if different froia owner) : ADDRESS: same Pffo,:E: (312) 407-6740 PHONE: DESIGN ENGINEER OF SYSTDI (if applicable): Marston/Kinney & Associates, Inc. ADDRESS: 2775 Crossroads Blvd., Suite 110, Grand Jct.,RYn6 PHONE: (303) 243-2386 INS ALL.NTION OF SYSTEM: P. Etters Construction Licensed Installer (see attached list): YES NO ADDRESS: 500 Lion's Head Mall, Vail, CO" 81657 PHONE: (303) 476-0410 PERMIT APPLICATION IS FOR: (X ) New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL —SE'. —FACE DTSPOSAL SYST,^.I: Street/Rural Address: Lake Creek Road —,-Edwards, CO 81632 Lot Size: 65 acres, see buildin ermit (lengthy) Legal Description: southeast 1 of Section 18, Township 5 South, Range 82 West, ado BUILDING OR SERVICE TYPE (checkagaoolQcable cateColozory C cate_er•:) (X) Residential - Single Family ( ) Residential - Quadplex ( ) Residential - Duple:c ( ) Co.-- ercial (state •sage) ( ) Residential - Tr_olec NUMBER OF PERSONS: 2 permanent, 2 intermittent WASTE TYPES (check applicable cate^_ories): ( ) Commercial or Institutional ( ) Non -Domestic Wastes (X) Garbage Disposal (X) Automatic Washer ( ) Other `TYPE OF INDIVIDUAL SET -.AGE DISPOSAT. S1'S77'-i PKn?nc,T)- NTrMRER OF BEDR00`IS : seven ( X) Ihaelling ( ) Transient Use ( X) Dish::asher ( X) Spa Tub (X) Septic Tank ( ) Composting Toilet ( ) Incineration Toilet ( ) Vault Privy ( ) Greywater ( ) Chemical Toilet ( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Potable Use ( ) Other ( ) Recycling, Other Use WILL EFFLUENT BE DISCHARGED DIRECTL'i INTO T.•.'AT='RS OF THE STATE: YES ( ) NO ( X ) IS SYSTT•I DESIGNED FOR tES S 1 HAN 2,000 GA LO`:S P = R DAY: YES (X ) NO ( ) WASTE:•!ATER FLOW REDUCTION' PLAN: YES ( ) NO ( X ) (I S Ve s , see attached was.t exi-te.~. Seew Leduc ti.on ,ne Jcods ) NOTE: The Env,&Lo;uneiLta.L' Hecce.-Lj'c O'a.i.c_nL may "Lcducc ti.e •-Leouited ab.sa-Lpticjt a,tea u;:on app:Lavae a3' an adcquatc ctas.tz:rat2•11 5<ccu .7eductLo;t ,�x ;c. SOURCE AND TYPE OF IdATER SUPPLY: ( X ) Well Creek/Stream Give depth of all wells within 200 feet of system: n/a - If supplied by community water, give name of supplier: SIGNATURE:.�a �c� - %Uv: w DATE: 6 /1) J87 - INFOUATION BELOW TO BE FILLED OUT BY ENVIRON.'IEhrfAL HEALTH OFFICER: GROUND CONDITIONS: Penc-Uzt G.7ou►cd Seope Dept. .to Bed'coel, (pe?c 8' P,to'iee Hofe) Depth .to Gnoundaca,te t Table SOIL PERCOLATION TEST RESULTS: 7Z5ZZtcs pe,•c .c nEL in Fo—Ze T l itt6w-tes pen inc/c .to Ho.ee #2 FINAL DISPOSAL BY: ( ) Ab,so.-ptc:-A Tten.ch., Bed o". P-Lt ri` 14 ( ) Evapo.ttajtspi.�cttion Above Gnou►cd D.i,spe,'sa.L' ( ) Saud Fi-Etct ( ) Undc g.%ou►cd Dispc-isae ( ) (Vas.texa.te'L Pond ( 1 O.the,Y 4,noujLt Pa.i.d: Recci.,)t Ncunbc-% �j/��lp Date: -`----------------------- _55/0------------------• NOTE: Site Plan must be attached to'application. See Building Permit Site Plan. (Env. Health Department - Rev. 4-07-33) EAGLE COUNTY ENVIRONI�XENTAL HEALTH OFFICE Date Routed Location 5//� - App i i cation -No Please revie,,i the attac' J Individual Se,rage Disposal System Permit Application and return it with this completed ^m to the Environmental Health Office. PLANNING: Complies wit Subdivision Regulations: Zoning Regulations: Recommend Approval: COINMIEINTS : ' BUILDING: Complies with - Building Permit Applied For: Building Permit Issued: Recommend Approval: COMMENTS: ENGINEER: Complies with - Roads: Grading: Drainage: Recommend Approval: COMMENTS: ENS/ I RON IENTAL HEALTH: Complies with - Floodplain Permit Necessary: I.S.D.S. Regs. Compliance: Recommend Approval: YES tin -RGVT71.1r7n ov Nelop - -- UMIC. i YES NO REVIE!•!ED BY DATE I I 1-7 I I - YES NO I RE%IIE':JED BY DATE _ YES NO REVIE14ED BY DATE I SUNDESIGNS ARCHITECTS 901 Blake Avenue GLENWOOD SPRINGS, CO 81601 (303) 945-2201 TO Marston/Kinney & Associates, Inc. 2775 Crossroads Blvd., Suite 110 ILcEUTEa orsTURZEDUURL DATE 6/22/87 S —0.86008 ATTENTION Norm Kinney RE: Monroe Property WE ARE SENDING YOU L2CAttached ❑ Under separate cover via us mail the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications Q Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION 1 6/22/87 copy of Chen & Associates letter re: Percolation Test THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted n For your use ❑ Approved as noted ❑ As requested ❑ Returned for corrections ❑ For review and comment ❑ ❑ FOR BIDS DUE 19 REMARKS ❑ Resubmit .copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PR!NTS RETURNED AFTER LOAN TO US COPY TO SIGNED: I'MV243 =7Wk &d..A%M 01471 It enclosures are not as noted, kindly notify us at once. Chen & Associates Glen Road 154 Glenwood Springs, CO 81601 Consulting Geotechnical Engineers 301945-7458 June 22, 1987 Subject: Percolation Test, Monroe Property, East Lake Creek, Eagle County, CO Job No. 4 198 87 Sundesigns Architects & Planners 901 Blake Ave. Glenwood Springs, CO 81601 Attn: Dean Moffatt Gentlemen: Casper Colorado 30nngt, Denver Ft Collins Phoenix Rock Springs Salt Lake City San Antonio D JUN 221987 SUNDESIGNS ARCHITECTS As requested, we performed a percolation test in an existing back - hoe pit at the subject site. Chen & Associates, Inc., previously con- ducted a subsurface study for design of foundations at the site and re- ported our findings to you on June 12, 1987. The percolation test was performed adjacent to Pit 2 near the east end of the proposed building. 'Ihe percolation hole was dug on June 19 and the test performed on June 20 after soaking. The test results are shown on the attached table. Based on the test results, and the soil profile encountered at Pit 2, the area appears suitable for a conventional infiltration septic system. After the infiltration disposal area has been determined, a percolation test should be conducted for final sizing. call. If you have any questions, or if we can be of further assistance, please Sincerely, Chen & Associates, Inc. By_.,w_ Steven L. Pawlak, P.E. SLP/lc attachment TABLE I PERCOLATION TEST RESULTS 6-20-87 Job No. 4 198 87 WATER DEPTH WATER DEPTH HOLE HOLE LENGTH OF AT START AT END DROP IN AVERAGE NO. DEPTH INTERVAL OF INTERVAL OF INTERVAL WATER LEVEL PERCOLATION RATE (In.) (Min.) (Inches) (Inches) (Inches) (Min./Inch) 1 48 10 12 10.75 1.25 8 10 10.75 9.75 1 10 15 9.75 8.5 1.25 12 MARSTON/KINNEY & ASSOCIATES, INC. 2775 Crossroads Blvd. Suite 110 GRAND JUNCTION, COLORADO 81506 (303) 243-2386 TO Environmental Health Office — Eagle County P.O. Box 179 Eagle, CO 81631 WE ARE SENDING YOU XJ Attached ❑ Under separate cover via_ ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ LIEUTEQ (IF MRAS uNUUML DATE Aug. 11,1987 JOB NO. 7062 ATTEN,E'Pic Edeen RE: Monroe Residence the following items: ❑ Samples ❑ Specifications COPIES DATE NO. DESCRIPTION 1 Application For Indvidual Sewage Disposal System Permit 1 Copy of Chen & Associates Letter re: Percolation Test 1 Cut Sheet of Leach Bed Tubing (Advanced Drainage Systems, Inc. THESE ARE TRANSMITTED as checked below: 1l For approval ❑ Approved as submitted ]K] For your use ❑ Approved as noted ❑ As requested ❑ Returned for corrections ❑ For review and comment ❑ ❑ FOR BIDS DUE 19 ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TODean Moffatt SIG (DRS) PRODUCT 2403 a wc., crown, Mux 014n. If enclosures are not as noted, kindly n . us at once. COLORADO DEPARTMENT OF HEALTH GENERAL SANITATION SURVEY REPORT FOOD AND DRUG I RM NAME .00ATION WNER ADDRESS %% IANAGER COUNTY (/E INSPECTION OF YOUR AT THE ABOVE LOCATION REVEALED THE FOLLOWING 1. DEFICIENCIES: PREMISES: ESTABLISHMENT TYPE DUST CLEAN OTHER / / 2. WATER SUPPLY: ADEQUATE 3. LET -LAVATORY: FACILITIES 4./ ASTE DISPOSAL: SAFE TYPE GOOD REPAIR CLEAN r-- C REFUSE PRODUCT WASTE TYPE -�� i� 5. VECTOR CONTROL: `SEWAGE RODENTS INSECTS VERMIN PROOF b. BUILDING: CONSTRUCTION MAINTENANCE CLEAN 7. EQUIPMENT: ADEQUATE GOOD REPAIR CLEAN STORAGE B. CONTAINERS -UTENSILS: CLEAN SANITIZED STORAGE 9. REFRIGERATION: CLEAN TEMPERATURE THERMOMETER STORAGE DRAINAGE ." 10. FOOD: OPERATION STORAGE TRANSPORTING NON-FOOD HANDLING OTHER 11. MISCELLANEOUS: ANIMALS DRESSING ROOM PERSONNEL HAZARDS OTHER ✓� UNSATISFACTORY - ExPLAIN IN REMARKS SECTION ' REMARKS: F� 1 �o << 5,E DATE: � (./ / v RECEIVED BY: FS•MFn 55 (1-71-50) SANITARIAN: r �. YJ t• n •�' ���fa' `jlrS �'�« «ti � � � r+ 1 y.� r. '.`1 � 'y+f+�r .a, f �%i� i,tf• 7. ip 10, ,t�'! •f. "'.�ngi c'�.r�1�+��r i1K•: �t a�'��r':� {r k.-;+��ti �i�f � x� '• 1 • + ... ,�,,�i �� ..,,',yam'" . + -s � ti, r s .i•'..� � �ry. ti{firy��0eSf�Y.y ti •ckiF+�•�a,yY' ,� �'�Xiy�} t' 7 j ,f ._o[•$to(=-Z* * lop f 1' 111111'' � Surface Original soil backfill • R tPf ' . min.► r min. DRAIN GUARD prolec five wrap (soil inter- face) Trench sidewall Drain holes, located 60 off bottom center fine, provide outlet fort-i;•. effluent. �w Trench bottom 1 Qmay^ i ,a -.01-8'or 10— Sludge retained in pipe '( to reduce soil interface J clogging � t , • ,'('j'Zd^;; 741 tt• � � SB2 S11St2Eit sm Ii2W standards for o The SB2 concept is the newest and most innovative in leach bed design. It was de- veloped by professional sanitarians, John Shroff and John Barnes. The system is now being marketed to contractors and suppliers exclusively by Advanced Drainage Systems, Inc. Years of research has proven the S132 system to be an effective alternative to con- ventional gravel leach beds when installed in areas suitable for conventional on -site soil absorption systems. In 1980, a research project was con- ducted to evaluate the performance of 100 S132 systems which had been installed in Montgomery County, Texas. The results of this study indicate that S132 systems function as well as, or better than, the conventional leach bed systems which were installed in similar soils. The report prepared by Dr. B. L. Carlile of Texas A & M University and D. J. Osborne of North Carolina State University stated: "On the basis of this study, the design criteria for SB2 systems should be based on the same soil and site parameters as a con- ventional (gravel) system. On sites where conventional systems should function satis- John Barnes, John Shroft developers of the SB2 system factorily, so should SB2 systems." The report states that the primary advan- tages of the SB2 system are to: A. Promote improved distribution of waste- water in the trench. B. Increase retention of solids in the pipe. C. Increase capillary movement of waste- water around the soil interface. D. Eliminate the need for gravel and reduce heavy equipment traffic. E. Reduce labor and installation costs. S1132 is available in both 8 and 10 inch diameter corrugated polyethylene tubing with specially designed perforations, en- cased in factory installed Drain Guard" pro- tective wrap. The S1132 gravel -less system provides as much storage capacity and surface area for effluent absorption as a gravel leachbed system. The SB2 tubing is designed to pro- vide increased retention of suspended solids. The result is a highly efficient, gravel - less, leach bed system that is much easier to install than conventional gravel absorption systems. Locating holes 60 off bottom center line creates additional sludge storage space. In if nc�fxn�r•:a�a�lnlrtumea�•a�f:wtt:t ?rl PIE ` Faster and easier to install The SB2 tubing can be installed with less labor and equipment on all types of site con- ditions where conventional gravel systems are permitted, using the same basic equip- ment and techniques. (See "SB2 Gravel - less Leachfield Installation Recommendations.") - IM am, "I I I. 'i",% . - � I DRAIN GUMP.D Protective Wrap The DRAIN GUARD protective wrap pro- vides an excellent soil interface for the pas- sage of effluent into the soil. The valleys of the corrugations function as additional stor- age capacity since the DRAIN GUARD fab- ric bridges the corrugations and allows for the free movement of the effluent out and ,i,ound the pipe. 1 Itr mlijor advantages of the SB2 system are the size of the tubing and the location of drain holes. The outside diameters of use 3 .and 10" SB2 tprovide an equivalent of 21, aril 3 s care feet, respec- tively, of soil absorp,t Q area per lineal foot. The location of the drain holes. 60' off the bottom center line, provides additional sludge storage capacity, which increases retention time. Drain Guard limits soil particle in- filtration and allows effluent to pass through to soil. DRAIN GUARD protective wrap is overlapped and sonically-welded to provide 360' coverage of line. Monitoring and Cleaning The ability to monitor and clean out the distribution line is an important feature of the S1132 system that is not possible with a gravel leach bed system. With an inspection port added at the end of the distribution line the sludge level can be easily monitored and the distribution lines could be back - flushed during regular septic tank main- tenance. Although back -flushing will not be necessary in most installations, it is important that the homeowner be able to check the sludge level. Drain Holes Sludge Inspection Port The large diameter tubing pro- vides greater storage capacity per linear foot and permits slow move. ment of effluent, therefore increas. ing retention time. Easy -to -use heavy-duty ADS fittings Split Coupling lryo 3"-311 8"- 811 4"-411 10"-1011 5"-511 12'-1211 6"-fill 15"-1511 Snip Adapter 1 3"-362 6"-662 4"-462 8"-862 5"- 562 Septic Tank Adapter ally" Non -Perforated Tubing 3'-351-300' Cods 4"-451--250' Coils 5"-551-165' Coils 6" - 651- 100' Coils Septic System B 851 -20' Lengths Leach Field Tubing i 10"-1051 -20Lengths (W to 3/4" dia. hole.) 12"-1251-20'Lengths q"__g02-10'Len the 18""-1851- 30510'Sec6ons 1-1-' Lengths (402 also available n coils.) (351 and 451 also available in bundles of ten- 10' lengths.) Snap Tee A r 3"-321 5"-525 4"-421 6"-626 d� Tee 494 cl 1 4" straight end fits ADS adapter 463 for ADS Plastic Tubing Offset Connector 8" x 4"- 840 10" x 4"-1040 Blind Tee i9f 3"-341 5"- 541 4"-441 6"-641 Septic Tee No. 495 adapts to cast Iron 45- "Y" Y W-322 5"-522 4"-422 6"-622 'SB2 Gravel -less Leach Bed Tubing Filter wrapped. 112" holes. 8" 8 10" diam. 20 ft. lengths. Advanced Drainage Systems, Inc., is America's leading manufacturer of quality corrugated polyeth- ylene pipe. Manufactured of selected polyethylene resins, ADS pipe meets the strictest product quality standards and industry specifications. In addition, ADS manufactures a complete line of fittings and couplings, simplifying installations for highway and construction drainage applications. From coast to coast, ADS tubing is available through the industry's most extensive distribution network. For the name of your local distributor, contact the nearest ADS sales office. Reducing Tee Muhiple) s'o 84 8to 8" 8" to 6" 8" to 5" 8" to 4" 1044--10" to 10' 10" to 8" 10" to 6" adapts to clay Distribution Boxes 1369- Regular Split End Cep 40 3"--331 8' 831 4"-431 10"-1031 5"-531 12' 1231 6"-631 15'-1531 Septic Vented Ell No. 497 4 ilow '.370-Hillside Sump Liners & Lids For Basement 45' ELL � Y1 1536 1537 4"-445 Regular Lid Heavy Duty Lid 9e'ELL ba 1r k+ At 1530 1524 3"-390 30' Liner 24" Liner 4" -490 Nationwide Sales and Manufacturing Network CALIFORNIA MINNESOTA Madera (209) 674 0054 Rochester 15071281.5450' (209) 674 0903- NORTH FLORIDA CAROLINA Lallolnnd (813) 665 8668 Charlotte 1711E rJ 7 0137' GEORGIA Rowland 1919r 422-3303 Montezuma (912) 472-75t,6 OHIO ILLINOIS London l6141852.9S54 Harvald (815)943-5477 V, i.11852-4067- Monncello (21 7) 76294,18 Napuleon (4I'll Y0 9%5 IOWA 019) 'A0585' Cresco 319) 547 3105 Wooster 12161 :.'64, 4949 Creston :5151782-8.,,65 PENNSYLVANIA Eagle Grove (515)448.510t Muncy 1711,546.7686 Iowa Gty (319)338-9448 TENNESSEE (319)3393689' Brentwood ib 151.E 739964' KENTUCKY TEXAS l.lverrnore (502)733.4324 Enn,s 1214)875-6591 Versailles (606)873.8046 VIRGINIA MASSACHUSETTS Buena Vista (7031261 6131 Palmer (413) 283-9797 WASHINGTON MICHIGAN Bellevue 1206i643.2'770' Bad Axe (5 17) 269-9506 Washougal (2f6)835.8622 Owosso (517) 723-5208 ;,nestm".1nr, Insist ors the ADS green stripe. It's your sign of quality—# 1 in the land. =03, ADVANCED DRAINAGE SYSrEMS INC Corporate Office / 3300 Riverside Drive, Columbus, Ohio 43221 / (614) 457-3051 1. ", nrf D,ainaga S"", '_ 1992 Ad r.9nrs ✓f« . l 11-11 .n U S A F,« xl '~S,N + nrarn (i,ard ra a A", s1«r«d T18d«ma111 If Advances] D,:«nay« iY,l % lnc US Pa1..n1 Nn 3649 M an0'1830373 « Tn« rr Slap« �, , 11 S P.—I and Tr« .1, 011— N c m m 0301 d<�a - -+ to 'Rid��r2 mom13o d 7 mmmm_ m3nwd ° : <av�c= nmc0°.to'' o a`° o CL m m <'°'a o 0 ^ m m o� m a LA. o mdnf A fDmro i '� D o c m o (0 o ° vN-'C - d= =7M ° RIO -;0Om y _(c m mao am < a C a dc O m D7C- n�=y- p n O y' 0 a m DRa. <I Z !?m Na...m��a ' O a3 yC H N O � nv m mm mr x q m6m ayDO C �to -0m o Cr CL 61 7 7 7 7_ a O Q d (O N ^ - OL a] NmOO m l7 �_.m�d _•m14 N� 7N� A O tu N d m a„ S aC 0, N m O w w d _ 7 w 0"a O m 0 0 C 7 fa aN m O O y =0 O m C w C (n San? _ rnycv c61 CD -•o�W D ° �n-i aD�- (� T(i 7J fD �3i y oZ2 O .1 O (D >In 'n'--yID w -7 n •� N . UD _ m M-73nD'�,'ti D �.. Q (D y L� `� f c o j O-O - y C - cL or)(1 ..In '� n .. L- ti r, 3 mvp a� Q C N a a O C=_ •. amo._m (D _ C 7 FIT O V, (D (j) 071 1 7 0)U) CT to O W < 2 !1 'n cn _ yCr -� - ?. �� O (n (� .� %D _ G +� ° m m LA '^ (D 7 s r O O J C D_.� 'DO O O O U T I O T� 31 D n O JCL � 7 n _ M < Q y - c C ^_ � w C 7 (D O • A� fl_ 7 G 07 tv m 'n n Nm S (n (( '0 (D < �'< ii- C wl ^ D 7 S f0 m S m O °��o r^ ad c my=rn Na3- v � �(n v m S mr2cTv: QPIS T' 7�nNn .... •.. O 'D m y � m °, � x D� rr 2 Cl c � -. T -: 'D S : VJ C 'D LU O 'C O W m a ,< 10 IQ M V Lb:) w C a j 5 7 0(D m (D 7 m to O (D 3 V (D 3 C 7 C (D (D j N N m L? �- (, 7 (n C N m� 'D iN 3 ?c. � rL � � -0, 3 2 a (n :D o(C D 2, W (D 7 Um) 0 (SD 7 > j \a 4 O 7-j 7 7 < ,D ❑ 2 C F"- -- C 4 0 3 N 75 - x- 'DD O r�W .o N7•• F,n 00'O-0 7 - Z, .i D (n 'D X V• :3 __,G (n (D ID 0 m 'D 'D CD a CP u:O C'r m nm aD cc .r fD (� V O rD r �' WLO < rn G`T'Dco 3D aa wR-m� -2� (D0 y�(aD �.�CD m -{ C:��(o m p .N S> w O a< C 0 (D 0 ro° �fnomo°'(n �aDb0<°O�<Dm :3< cr awn°' GD ID &0 -0ocD:'w-00a m N � 'D IT) m co'(omm?a CD °°,<oD,cm m S N a� S m 0 7 m m f w C ND pN�(DN cy cr mNmc3� O Ow n a 0) =c n (D .((D 0)S O (D D w :Dn pj 3GNoa3EN DQCDw..w �Q w,<,o 43 ='cD � m 1�<w 'w(D S d' (D (o w > BCD acDmaw 5 jc, n1 )S(Dw (D (A (Dco Z �T�a� o C^ Z 7 L ~ () 'O ^ 3 j�. (D OJ 0 �I -D � rt n3 'G K G r Ij ncr G - (D a) CL O (D ww�o ... 3 �0 (� .J w 0 mCop :r cnD ° 3 ;I CD U) - m3cnn 3`D (4 Dttly 7(D p (D N fi l 1 G 0 o 3 c-D t... "<nCLoN3 rya C = j G N y' "+ � .0 w (D 7 _ o' < N r. O w S o N C. CR in w N o 3 � 3 D (.D(D <O2 Q 4! Cr w <�/�►. 0 N m C D ID G 1 4 S p = G ID O •� (D w v G o PD n %Doo�o 0- cr 3 S p o_ w � Fz3c(� 7 D (D C - � s 'D -< (D - (e ro SB2 Installation Guidelines i NTRnni irT i nN The SB2 system is an advanced alternative to gravel filled soil absorption trenches for septic tanks. SB2 corrugated polyethylene tubing is encased in a factory installed DrainCuard® protective wrap. It is available in both 8-inch and 10-inch inside diameters, and in 20-foot lengths. SITE FACTORS & SYSTEM LAYOUT 1. SB2 may be used on any site suitable for conventional gravel drainfield lines. 2. High water tables and/or slowly permeable soils severely effect the performance of all soil absorption systems. 3. S132 systems can utilize any method of effluent distribution used in conventional systems, i.e. distribution boxes, hillside boxes, serial distribution, manifolds, etc. For systems utilizing serial distribution, the S132 should be installed with each line following the contour of the land. Individual lines are to be joined with a connecting lateral that provides a one -inch maximum head on the upper line (Figure 1). This insures that the upper line is full to capacity before any effluent can overflow into the next line. 4. All plumbing connections between the house and the S62 drainfield, including the septic tank, should be identical to those specified in the local regulations for conventional gravel systems. 5. All setbacks and distances from soil absorption lines to property lines, wei;c, lake shores, seasonal groundwater, bedrock, etc., should be specified as is required in the local rules and regulations for conventional gravel systems. 6. SB2 can be used in conjunction with any locally approved septic tank or aerobic unit. TRENCH EXCAVATION 1. Recommended trench width for the S82 gravel -less drainfield is 18-24 inches. Tight soils may require a 24-inch wide trench to insure proper backfill around the bottom and sides of the 5132 (Figure 2). 2. Trench depth is normally 18-24 inches to allow for 6-12 inches of native soil backfill. No gravel is required. The trench must be deep enough to insure that the flow line of the septic tank is at least one inch above the top of the SB2 (Figure 3). 3. Trench lengths should not exceed the maximum allowable lengths for conventional gravel systems. The trench bottom should be level with a maximum slope of 1" per 100 lineal feet. PIPE INSTALLATION 1. The factory installed black shipping bag must be removed prior to placement in the trench. 2. The 20-foot lengths of SB2 must be placed in the trench with the green stripe up and joined with ADS split couplings. The DrainCuard@ should then be pulled over the joint to reduce soil infiltration. 3. Either plain end caps or optional inspection/cleaning ports (Figure 4) can be used at the end of each line. 4. S132 lines should be held in place during initial backfilling to prevent movement of the pipe in the trench. 5. A loose granular soil backfill will enhance the performance of the 582 in slowly permeable soils. 6. Large clumps and rocks should not be used as backfill. 7. All drainfield installations should be seeded as soon as possible to prevent soil erosion due to rainfall. Reducing Tee - Ground Level 10" x 4" or 8" x 4" 1" MIN Offset Adapters May Be Used in Green Lieu of ADS :Stripe Reducing Tee 4" Smooth Pictured Wall or Green 4" Corrugated �— , Stripe SB2 Pipea \ Trench Separation Per Figure 1 State or Local Code Connecting Lateral -Serial Distribution SB; (Not To Scale) 18-24'e6" MIN. Ground LevelEnd Cap Drain Guard Green Location Nylon Protective Wrap 8" or 10" Non Perforated Spacer Stripe May Be Necessary 18-24"" To Extend Cap 8" or 10" 8" or 10" To Ground Level SB2 SB2 Inspection Port (Optional) Figure 4 Optional Inspection/ Figure 2 Drainholes Cleanout Port S132 Cross -Section View (Not To Scale) (Not To Scale) 4" Sanitary Tee Liquid Level Tank May Be Multi -Compartment Ground Level 8" or 10" Septic Tank Flow. Line— End Cap 7"x4 10" x 4" Offset Adapter 8" or 10" S132 Septic Tank Figure 3 S132—Side View (Not To Scale) SECTION 66-20-19(2) OF THE COLORADO PURE FOOD AND DRUG LAW IS QUOTED BELOW; UPON COMPLETION OF ANY SUCH INSPECTION OF A FACTORY, WAREHOUSE, CONSULTING LABORATORY, OR OTHER ESTABLISHMENT, AND PRIOR TO LEAVING THE PREMISES, THE AUTHORIZED AGENT MAKING THE INSPECTION SHALL GIVE TO THE OWNER, OPERATOR, OR AGENT IN CHARGE A REPORT IN WRITING SETTING FORTH ANY CONDITIONS OR PRACTICES OBSERVED BY HIM WHICH, IN HIS JUDGMENT, INDICATE THAT ANY FOOD, DRUG, DEVICE, OR COSMETIC IN SUCH ESTABLISHMENT CONSISTS IN WHOLE OR IN PART OF ANY FILTHY, PUTRID, OR DECOMPOSED SUBSTANCE OR HAS BEEN PREPARED, PACKED, OR HELD UNDER INSANITARY CONDITIONS WHEREBY IT MAY HAVE BECOME CONTAMINATED WITH FILTH OR WHEREBY IT MAY HAVE BEEN RENDERED INJURIOUS TO HEALTH. A COPY OF SUCH REPORT SHALL BE SENT PROMPTLY TO THE DEPARTMENT. 1 m ?ir � -A � r � O < m w m o r r a CJ 11 ut5uz zybb E. Laxe ureeK xa Monroe Properties JOB P JOB NO. JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL ,4 _ PERMIT # 802 OWNER: MONROE PROPERTY COMPANY =:. LOCATION: 2966 E. LAKE CREEK ROAD EDWARDS INSTALLER: RON AST _ SIZE OF TANK: 2- 1000 GALLONS TANKS ` +`�` -- Via• DWELLING: RES. SINGLE FAMILY PERC RATE: 1 INCH IN 10 MINUTES ABSORPTION: 2 - 80 FT. LATERALS FINALIZED: 10-5-87 BY: ERIK EDEEN ROFIT COSTS PRICE ' ROFIT Printed in U.S.A.