HomeMy WebLinkAbout63 Lariat Loop - 210505402001 - 0477ISEAGLE C TY DEPARTMENT OF ENVIRONMEI""1L HEALTH rERMIT MUST BE POSTED BOX 81 1 6th & Broadway CALL FOR FINAL INSPECTION Eagle, Colorado 81631 PERMIT0 4� (this does not constitute a building or use permit) Owner WARNER PROPERTIES System Location LOT R-8 - South Forty Subdivision Edwards, CO Licensed Contractor * Conditional Construction approval is hereby granted for a Septic Tank or Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Perc rate 1 inches in 14.3 minutes sq. ft. absorption area per bedroom # of bedrooms x May we suggest Date November 3, 1980 FINAL APPROVAL OF SYSTEM: sq, ft. minimum requirement Inspector gallon MINIMUM REQUIREMENTS: This system is engineer - designed. All requirements of that design must be followed for installation of septic system; 1,250 gallon sptpic tank and minimum 1500 sq. ft. evapotranspiration bed. Erik W. Edeen No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to covering any part. Septic Tank cleanout to within 12" of final grade or aerated access ports above grade. �`' rP deer materials and assembly. Z�dequate-absorption (or dispersal) area, _414equate compliance with permit requirements. Adequate compliance with County and State regulations/req uirements. Date November 3, 1980 Inspector Erik W. RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE * CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to authority granted in 25-10-104, CRS 1973 amended 25-1-614, CRS 1973 2. This permit is valid only for connection to structures which have fully complied with County Zoning and building requirements. Connection to or use with any dwelling or structures not approved by the building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. s• 28 3. Section III,4 requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications con- tained in the application of permit commits a Class I, Petty Offense ($500.00 fine - 6 months in jail or hnth Inter -Mountain Engineering ua. PERCOLATION TEST RESULTS AND SEPTIC RECOMMENDATIONS LOT R-8, SOUTH FORTY SUBDIVISION, FILING NO. I EAGLE COUNTY, COLORADO ' PREPARED FOR: WARNER PROPERTIES INC. OCTOBER 9, 1980 BOX C-100 1420 VANCE STREET AVON, CO 81620 LAKEWOOD, CO 80215 949-5072; DENVER 893-1531 232-0158 SCOPE This report presents the results of a Percolation Test and provides Septic Recommendations for the proposed residence located on Lot k-8, South Forty Subdivisions Filing No. I, Eagle County, Colorado. SITE INVESTIGATION The field investigation performed on October 6, 1980 consisted of r, drilling three borings to an average depth of 30 inches. Percolation tests were performed on October 7, 1980. Locations of the test bor- ings were shown on the enclosed drawing. Results of the Percolation Tests are included in this report -- see PERCOLATION TEST RESULTS. SITE LOCATION AND DESCRIPTION The site is located in a part of Section 5, Township 5 South, Range 82, West of the 6th P.M. Eagle County, Colorado. More partic- ularly, the site is described as Lot R-8, South Forty Subdivision, Filing No. I. The site slopes downward to the north, and vegetation consists of sage brush and native grasses. SUBSURFACE AND GROUNDWATER CONDITIONS Subsurface conditions are fairly uniform with silt, highly organic, to a depth of 1 1/2 feet; silt with clay and traces of sand, 2 SUBSURFACE AND GROUNDWATER CONDITIONS - cont. slightly moist, firm, to a depth of 5 feet; underlain by sand and gravel with cobbles and boulders. No groundwater was encountered. DCr-)nOI AT I(1 KI TCCT 0U C I I I TC A total of three Percolation Tests were run on the site using the standard test method as described by the Eagle County Individual Sewage Disposal System Regulations. Test results varied between 14 and 15 minutes per inch. _ Percolation Test holes were presoaked on October 6, 1980, and the test was performed on October 7, 1980. Results are as follows: TEST HOLE NO. MIN/I Inch Deep 1 14 2 15 3 14 Average time for I inch drop = 14.3 mins. SEPTIC SYSTEM RECOMMENDATIONS Recommended is a minimum 1250 gallon compartmented septic tank to be followed by a minimum 1500 square foot evapotranspiration bed. Bed should lie a minimum of ten feet from property lines and twenty feet from the proposed residence. Inspection of the system should be made by a representative of Eagle County Health Department prior to backfilling. 3 CONCLUSIONS The findings and recommendations of this report have been ob- tained in accordance with accepted professional engineering practices in the field of Foundation Engineering and Soil Mechanics. There is no other warranty, either expressed or implied. If we can be of further assistance, please do not hesitate to call. Sincerely, INT R-MO AIN ENGINEERING, LTD. G. homas Allen Field Engineer Reviewed and Approved by; Jeffery M. Spanel, P.E. Vice -President COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO September 16, 1992 Ms. Janice Woodley Woodley and Associates P.O. Box 1370 Edwards, CO.. 81632 Dear Ms. Woodley, 500 BROADWAY P.O. BOX 179 EAGLE. COLORADO 81631 FAX (303) 328-7207 As we discussed on the telephone yesterday, my office has received a complaint of septic odors emanating from the property managed by you at 0063 Lariat Loop in Edwards South Forty Subdivision. I visited the property on September 10, 1992 and detected no odors. However, I did discover a piece of broken sewer PVC on the ground with some evidence of waste water having surfaced at some time in the past. Since the dwelling was vacant at the time of my inspection, I was not able to determine whether the septic system is in fact failing or not. The septic system was originally permitted in 1980 under Permit # 477. It was designed by Intermountain Engineering and consists of a 1250 gallon septic tank with 2016 square feet of seepage bed. I've enclosed a copy of the portion of the site plan to help you locate the system components. I'm sending a list of our licensed Systems Contractors to help you correct the apparent problem. Please contact this office with your findings by September 25, 1992, so we can determine if an Individual Sewage Disposal Permit will be required. If you have further questions, don't hesitate calling. Sincerely - Raymond Merry, RE Enviro ental Healt. ision CC. ISDS File #477 Complaint File le- '�_7/-f® DATE REFERRED _ S� EAGLE COUNTY ENVIRONMENTAL HEALTH ROUTE FORM NAME APPLICATION NO. LOCATION Please review the attached application and return it and this completed form to the Environmental Health Office..* =, ITNIN(i_ Comments: _BUILDING: t/ Other Comments: RNGTNEER; Comments: Complies with: Yes No 'Reviewed By Subdivision Regulations Zor}ing Regulations r�GCC ' Recommend Approval Set Backs _ Site S Recommend Approval (not tom' nec Roads Grading Dra' e Recommend Ap INT. JOB ADDRESS - - OWNER 2 Of �3 Q S(,/, EAGLE COUNTY APPLICATION FOR PERMIT TO WORK IN COUNTY RIGHT OF WAY 1. Work is for: (circle those that apply) WATER, SEWER, GAS, ELECTRIC, TELEPHONE, TV CABLE, DRIVEWAY ACCESS, OTHER 2. Show roads with names, buildings, and location of cut or driveway (with dash lines) on 8%"x11" sheet. R] NOTE: Constructing plans and specifications prepared by a professional Engineer registered in the State of Colorado may be required by the County Engineer. Road Cut Dimensions: WIDTH LENGTH DEPTH 4. Square feet of pavement to be repaved 5. Lineal feet of pavement to be saw cut 6. DATE START DATE COMPLETE 7. Is all material, labor, and equipment available to complete work? 8. Supplemental sheets have been completed and are attached hereto and made a part of this application. 9. Special conditions: 10. 1 certify that I have read all requirements of the RESOLUTION and will abide by the same, and that all utilities have been notified as required. (d ate) (applicant's signature) APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT 1. DESIGN EN 1 EER OF SY M (if applicable): Intermountain Inc. S anel Bow —b��° AIa ADDRESS: �� � X7� PHONE: 949—MM 5072 2. PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM: Hoe & Grow Inc. ADDRESS: P.O. Box "E", Edwards, CO 81632 PHONE: 949-5167 3. BUILDING OR SERVICE TYPE: (Check applicable category) (x) Residential — Single-family dwelling ( ) Residential — Triplex ( ) Residential — Duplex ( ) Residential — Quadplex ( ) Commercial — State usage # Persons 1 family # Bedrooms 4 4. WASTE TYPES: (Check all applicable): ( ) Commercial or Institutional (x) Dwelling ( ) Garbage Grinder ( ) Non -domestic wastes ( ) Transient Use (x) Dishwasher ( ► Other (x) Automatic Washer 5. SOURCE AND TYPE OF WATER SUPPLY: ( ) Well ( ) Spring ( ) Creek or Stream Give depth of all wells within 200 feet of the system: If supplied by community water, give name of supplier: South Forty Water qystem (Bill Williams) 6. TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (x 1 Septic Tank ( ) Aeration Plant ( ) Chemical Toilet ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, Potable Use ( ► Pit Privy ( ) Incineration Toilet ( ) Recycling, Other Use ( ) Greywater ( ) Other 7. 1 hereby certify that4J2aye read a amined this application and know the same to be true and correct. SIGNATURE %l /S "'� DATE October 15, 1980 0477 Lt � #3, South 4 JOB NAME Subdivision NO. JOB LOCATION BILL TO DATE STARTED i 0 DATE COMPLETED DATE BILLED L- JOB COST SUMMARY TOTAL SELLING; PRICE TOTAL MATERIAL Z(i i CLll1(� (K- ' 11 ( i C �1 �` L' f, j� 4BOR PERMIT # 477 LANCE TAX OWNER: R- :OSTS LOCATION: Lot-"- - South 40 Subdivision - Edwards INSTALLER: SIZE OF TANK: This system is engineer -designed. All requirement of design to be followed for installation of septic system; 1,250 gallons tank "OTAL JOB COST DWELLING: PERC RATE: one inch/ 14.3 minutes GROSS PROFIT 1500 sq.ft. evapotranspiration bed. LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT Finalized: 11-3-80 By: Erik W. Edeen JOB FOLDER Product 277 ®® NEW ENGLAND Printed in U.S.A. NORTH /"= 20` 7360 S 89 026 /191 E 54. 60� 7370_ 7 1n 4 -J - s L%.'0 V ,� II I ��\►�t�t_ II► Ol 11l DllAl OVLL nviv 7350 L-172.60 4 10002 "27" R = 954. 93� I , � G I \y� 4PERFORATED PVC V W 9� Nn 1 / / A 1� A /h /HOLE IOCATION_ 4x 4 CROSS I-1 b�k ;�� 4„ TEE IL l PVC 21 / 1250 GALLON I SEPTIC TANK 1 h 1 4. _V4" to ll/2"WASHED ROCK 20" 21.0 --- -- - - r 2/.0' - 5`8" .f. - 5' 8° J_ 5/ 8" 2.0` 4 'PERFORATED PVC (T YP) c.`�o��4°$��do✓� ago �Jl �Il('�11J STR,W LAYS S TInA 4 A 3 0" COVER M/N. o�0cO0c�o°o p doo:0" .o•pao (Q�y� qp ° 3/4 to l 1/2" WASHED ROCK SCALE l= 2/� / C" i ///= = / iMXF ii 57RI^W �,Ai'ER ' N. 4 45 ELLS �� A (IF REDU/RED/ - : • : Q : , : , a- o° 6"MIN. �. 77 D"O YO i 2.0 .. B' ECTION11S SCAL E: l = 2` NOTES; 1. All work is to comply with the Eagle County individual sewage disposal regulation dated October 1, 1973 - as amended. 2. It is recommended that all pipe noted as PVC comply with ASTM D-3034, SDR 35. Regardless of the pipe choice, the manufacturer's require- ments for installation and backfifI are to be strictly followed. 3. It has been assumed that the 1250 gallon septic tank as recommended will be a precast concrete tank meeting Section V Qf. the Eagle County individual sewage disposal regulations. If a cast -in -place tank is desired, it will be acceptable; however the engineer is to be provided with shop drawings prior to con- struction. 4. It is recommended )ut not required to provide the 411.PVC riser as shown. The purpose of this riser is to provide air to the bed and to allow for the easy introduction of chemicals into the bed for maintenance. 0 1<7 � r 5. Topography and slope calculation interpolated from the Preliminary Plan for the South Forty Subdivision by Richards Engineers, Inc. / Oat. A.•..■lof.■ • P O BOX C 100 Inter -Mountain 1420 VANCE STREET 'y AVON.COLO 81620 LAKEWOOO.COLO,60215 �••`' /O/.311W REV1, APT/C ;wK LOCAT/QN (303) 949 5072 EngineeringLtd. (303) 232-0158 f 1 L 0 T R— 8 SOU THFOR T Y V �023No 4 E O'­ aY SUBDIVISION FILING NOIioi24iaR.o Checked SEPTIC TANK � SEEPAGE Scale. M s RED RECOMMENDA TIONS As sN' m /or / APPROX. LOCATION EXISTINU UKuu/v"/ 5 % PROPOSED GRADE DRIVEWAY CUTS NOT TO EXCEED A 3:1�rSLOPE RATIO , ], C.ur� A 16`)pi -zb 0.,r �•. �... w.j.�:. tee. e!b �. 20, X is so C.M. P. DETAIL �A�� / BULL RUN 7350 7360 R= 954.93 i / S89°26�19E 54.60� L= 172.60 D /00 02'27" 16.57 7370` -- -- SEE DETAIL 1 I i —/7 SETBACK LINE � 25'lilt 0 ll/i�ill � fill, l 1 h. t iillh/ 1SNOW/�SyORAGELn /' i 1 I GRASS GRASS J'Al i r LEACH l l v I � �u 1„� � * � '' - c• SEE 1 / IL FIELD F / I LOT Y� �'R 8 A 1 Y \■_ IV 6J`o �� ;. . • \ SEPTIC TANK4e4 -` i I Q t } _ 15 BUILDING SET BACJ LINE. . /7j ov BUILDING WALL /l y GRAVEL / FILTER GRASS V. VAPOR BARRIER DETAIL Ir S / TE /NFORMA TION LOT SIZE; 0. 822, acres 35,806 sq. ft. _ 4 AREA OF IMPERVIOUS COVER: 5,500 sq. ft. LANDSCAPE INFORMATION.' DISTURBED AREA TO BE REVEGETATED WITH REN.TUCK.Y .SLUE GRASS, ASPEN, AND BLUE SPRUCE Oats NORTH 1= 20 Revisions