HomeMy WebLinkAbout909 Ute Forest Rd - 210704401001 - 1533-95r r11771, EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 �'� Telephone: 328-8755 ft) (E j YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1533 Please call for final inspection before covering any portion of installed system. OWNER: David Tanser PHONE: (970) 476-6100 MAILINGADDRESS: 953 South Frontage Rd. West#203, city: Vail Stade: CO ziP:81657 APPLICANT: David Tanser PHONE: (970) 476-6100 SYSTEM LOCATION: Lot B-1, Ute Forest, W. Squaw Cr,TAXPARCEL NUMBER: 2107-044-01-001 LICENSED INSTALLER: Strait Excavation Services LICENSENO: 31-95 DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE 13ED 1423 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install 40 infiltrator units as requested by owner. Install in serial distrib- ution in trenches. Rake all trench surfaces exce t com act the end pipe runs from one t- c to the next trench. Install inslection portals in each trench, and a cleanout between the a1 Cent -for final inspe-e-�on t prior to backfil ENVIRONMENTAL HEALTH APPROVAL: ° t DATE: O z j p CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1440 SQUAREFEET. via 40 infiltrator units INSTALLED SEPTIC TANK: 1500 GALLON 165 DEGREES 44 FEET FROM cleanout near garage SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY x YES NO COMPLIANCE WITH COUNTY t STATE REQUIREMENTS: X_ YES _ NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED, COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE:AUgUSt 29,1996 ENVIRONMENTAL HEALTH APPROVAL: i DATE: (RE -INSPECTION IF NECESSARY) n€ APPLICANT! AGENT: RETAIN WITH RECEIPT RECORDS OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT# CHECK# tSit Plan MUST be attached) ISDS Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************** PROPERTY OWNER: r`' PHONE: MAILING ADDRESS: ;L3 _sue <, r , 4� s / A, �- .7 APPLICANT/CONTACT PERSON* PHONE: ( ) MAILING ADDRESS: LICENSED ISDS CONTRACTOR: 7 HIONE: ( )73,2J COMPANY/DBA: ADDRE 71 �- a ' 17jI f PERMIT APPLICATION IS FOR: (� New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Lie t` Legal Description: Subdivision: Filing: —Block: Lot No. Tax Parcel Number: - ' - - Lot Size:. -,r w Street Address: 'e Az s 71 *************************************************************************** BUILDIN TYPE: (Check applicable category) Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF -WATER SUPPLY: (Check applicable category) Well ( Spring ( ) Surface, ( ) Public Na e of Supplier: Number of Bedrooms 1171- Number of Bedrooms Type _- *These systems re iir*/de88 n byf a Rec stered Professional Engipee SIGNATURE: TO BE COMPLETED BY 'THE AMOUNT PAID: / F-"v\1- i Date: 6 Y f RECEIPT #: DATE: CHECK #: CASHIER: Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: October 4,1995 TO: Strait Excavation Services FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No. 1533-95 Tax Parcel #2107-044-01-001. Property Location: Lot B-1, Ute Forest, West Squaw Creek. Tanser residence. Enclosed is your ISDS Permit No. 1533-95. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. Installation must be completed by December 1 for all new construction for which permits were issued prior to November 15. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328-8755. cc: files Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO August 29, 1996 David Tanzer 953 South Frontage Rd. Vail, CO 81657 RE: Final of ISDS Permit No. 1533-95 Parcel #2107-044-01-001. Property location: 909 Ute Forest Lane, Edwards, CO. Dear Mr. Tanzer: Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Information Brochure Final ISDS Permit cc: files Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 12, 1995 Dear Applicant, Eaelc County Building P.O. 13ox 179 500 Broadway Eagle, Colorado 8 163 1 -0179 The Environmental Health Division would like to notify you to make a formal request to extend your Individual Sewage Disposal System(ISDS) Permit the 1996 construction year. The Environmental Health Division discontinued percolation tests on November 15, 1995 and final inspections on December 2, 1995 due to climatic conditions. ISDS permits are active for 120 days after the date of issue if no Building Permit has been issued for the same property. If a Building Permit has been issued for the same property the ISDS will expire at the same time as the building permit. If you still plan to apply for a Building Permit this year or in the early months of 1996 you will need to have a percolation test conducted before your Building Permit will be released. You will have to contact a Registered Professional Engineering(RPE) firm to conduct your percolation test. If you have had your permit issued and have not had your final inspection completed, but plan on constructing the system in the next few weeks, please give our office a call and we will evaluate your permit on a case by case situation. Please give the Environmental Health office a call at 328-8755, if you have any questions regarding your permit extension process. cc: ISDS Permit #L533-y5 File P. O. BOX 5408 VAIL, CO 81658 970-476-6100 FAX.476-6109 December 30, 1995 Ms. Janet Kohl Eagle County Environmental Health Eagle County Building P.O. Box 179 Eagle, CO 81631 RE. ELK RIDGE RANCH SEPTIC PERMIT NO. 1533-95 Dear Janet: Thank you for your letter of December 12, 1995 informing me that it is necessary to request an extension on the above permit while we are awaiting the information you requested from Mr. Robert Strait. Please treat this letter as a request for an extension of the Individual Sewage Disposal System Permit. By way of copy of this letter, I have reminded Mr. Strait that the additional information you requested be furnished at the earliest opportunity. I am forwarding to him a copy of the cover sheet you faxed to me last week as an qutline of that information. Please do not hesitate to call should you have any further questions. DAT/tad c.c. Mr. Robert Strait wndivl wplute Wr-sever Tank VTank hot 1-e�— Yl 0 ISDS Final Inspection Uta,vk OZci � , Completeness Form ku-LC4� q--� is gal. Tank Material �,UY1 A U is located ft. and lb5 degrees fromlie (permanent, lap r Tank is located ft. an (permanent landmark) Tank set level. `L Tank lids within 8" of finished grade. Size of field 1 v 2 _ units42W lineal ft. Technology Weanout is installed in between tank and house(+ 1/100ft). There s a "T".that goes down 14 inches in the inlet and ou let f the tank. T'^' et and outlet is Baled with tar tape, rubber gasket etc. . L/ Tank has two compartments with the larger compartment closest to the house. Measure distancative direction to field.S-IA� /� Depth of f i ld 11/2 A 1�ft �)J Soil interface ed. Inspection portals at the end of each trench. Y Pro.per distance to setbacks. Other 1 • 1 1 e s gcBL: remen s . Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: 'k1d �i'►'LQ.� `i'0 ..t.I,rl.� -[.� C� b-Tit.f/L q.- tki 1r Setbacks C� CA a V aU;tA ¢UU 5 Well Potable V House Property Lake ry&Aanok DP'ain ja_ Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 _ 5 10 50 10 * 0 <-, 3 qa 6 — q �2- 15 NEES MINEIR ENEXROM.91401! ■■■!■■■ SOMMIN■■■ S HEM■!■ ■E■i■■ !■■■■NEENIIsom■■■ ■■■■ ■■E!..5'1�■�ii■■!■!■ ■■!■ UNEWSIMBERE■!■■■■MM■■■■ M■�11■�il�!! ■■■■■■■■■�■■■i IiRl�l■,fC�l��7 ■ ti�■■■■■�■■■■ UENUMIMMMUMM■■■■ ■ONSON NEES ■!■■■■ins■■■■■!■■!■■!■ Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 October 4, 1995 Strait Excavation 2503 Cisar Ct. #2A Glenwood Springs, EAGLE COUNTY, COLORADO Services, Inc. CO 81601 RE: Elk Ridge Ranch, Tanser residence. Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 It has come to our attention, that your company has begun installation of an Individual Sewage Disposal System (ISDS) on the above referenced property. This particular ISDS has not yet been permitted for alteration/construction. 4.03.29, Eagle County Land Use Regulations states: "Any person who commits any of the following acts or violates any of the provisions of this Article commits a Class I Petty Offense as defined in Section 18-1-107, C.R.S. 1973 as amended: 1. Constructs, alters, installs, or permits the use of any individual sewage disposal system without first having applied for and received a permit as provided in these Regulations 2. Constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application or permit...." Consider this your only warning. Any further violations will be turned over to the attorney's office for civil and/or criminal proceedings. If you have any questions, feel free to call me at 328-8755. Sincerely, Raymon Mer y,t�;HS Envir entaHealtY Hager cc: Keith Montag, Cofununity Development Director James R. Fritze, Eagle County Attorney conditioned to within 2 percent of optimum moisture content, and compacted to the recommended compaction shown in the following table. The recommended compaction varies for the given use of the fill. Use of Fill Recommended Compaction Percentage of the Standard Proctor Maximum Dry Density (ASTM D-698) Percentage of the Modified Proctor Maximum Dry Density (ASTM D-1557) Below Structure Foundations 98 95 Below Slab -On -Grade Floors 95 90 Backfill (Non -Structural) 90 90 We strongly recommend that a representative of our office observe and test the placement and compaction of structural fill. Fill placed below foundations or slab -on - grade floors is considered structural. It has been our experience that without engineering quality assurance, poor construction techniques and habits occur which result in poor foundation and slab performance. PERCOLATION TEST The percolation soil profile pit was dug on May 23, 1995 with a backhoe at the locations shown on Fig. 2, Locations of Exploratory Test Pits. A field engineer from our office was on the site to supervise the digging of the percolation soil profile pit and visually classify and document the subsurface soils and ground water conditions. The subsurface conditions are shown in Fig. A-1, Log of Percolation Soil Profile. E The subsurface conditions encountered within the percolation soil profile pit consisted of 2 feet of topsoil underlain by a moist to very moist, loose, tan, grey, clayey, gravelly, sand and silt to a depth of 4 feet. Below 4 feet, to the maximum depth explored of 6 feet, the subsurface conditions consisted of a moist, hard, tan, grey, weathered sandstone. Because bedrock was encountered at a depth of 4 feet below the ground surface, alternatives to a standard leach field design needs to be considered. The percolation tests were performed on May 26, 1995 by digging 3 shallow percolation holes by hand. The location of these holes can be seen in Fig. 2, Locations of Exploratory Test Pits. The holes were located approximately 30 feet from each other. The tests were then performed by a representative from our office by filling each hole with water and allowing the subsurface soils to become saturated. Once the soils were saturated, the water levels were measured at constant time intervals and percolation rates were calculated for each interval. The results are shown in Appendix A, Percolation Test Results. The last column of the table provides the water percolation rate for each time interval. The water percolation rate varied between 2 to 40 minutes per inch. We recommend designing the leach field for at least 40 minutes per inch. LIMITATIONS Although the exploratory test pits and the percolation holes were located to obtain a reasonably accurate determination of foundation and leach field conditions, variations in the subsurface conditions are always possible. Any variations that exist beneath the site generally become evident during excavation for the structure. A representative from our office should observe the completed excavation to confirm that the soils are as indicated by the exploratory test pits and percolation soil profile pit and to verify our foundation and floor slab recommendations. The placement and compaction of fill, as well as installation of foundations, should also be observed and tested. The design criteria and subsurface data presented in this report are valid for 3 years from the date of this report. If we can be of further assistance in discussing the contents of this report or in analyses of proposed structures from a soils and foundation viewpoint, please call. KOECHLEIN CONSULTING ENGINEERS By Scott B. Myers, Engineer ®`eo�� t "Z4 , Y _ L l \ Reviewed by C9 William H. Koechlein, P.E., President 'f 12 TP-2 TP-1 1 } r ` ` / TP-4 I ` / TP-3 41 P-1 SCALE: 1 20` PTP P-2 Pi JOB NO. 96-90 FIG. 2 TP-1 TP-2 TP-3 TP-4 APP.EL. 100 APP.EL. 100 APP.EL.95 APP.EL. 97 0 UJ ti N nI IV LLl WC=12 (L W WC=6 U. LL '-200=8 WC=7 Z Z 5 5 N ax> F WC=6 d W-200=13 LU L- 10 10J LEGEND: r~++ TOPSOIL .,r GRAVEL,Sandy,Clayey,Boulders,Moist,Medium dense to dense,Black,Orange *+A SANDSTONE,Weathered,Lenses of clay and silt,Moist,Medium hard,Tan,Red,Grey,Black DISTURBED SAMPLE. Obtained from backhoe cuttings. Indicates backhoe refusal. NOTES: 1. The Exploratory Test Pits were excavated on May 19, 1995 with a backhoe. 2. No free ground water was measured at the time of excavation. 3. The Test Pit Logs are subject to the explanations, limitations and conclusions as contained in this report. 4. Laboratory Test Results: WC - Indicates natural moisture content (%) -200 - Indicates percent passing the No. 200 sieve (%) 5. Elevations of borings are based on a relative elevation of 100 for test pit TP-1 FIG. 3 JOB NO. 9b-90 �F PTP 0 .v N 0 11, N w w F.. U. w w oneZ�' Z 5 • 3 ` LL Z 7 5 a w �. a w a 10 10 LEGEND: N rV Nv TOPSOIL SAND and SILT,Gravelly,claye Mo' Y. ist to very moist,Loose,Tan,Grey SANDSTONE,Weathered,Sandy,Lenses of Tan,Red,Grey,Black clay and silt,Moist,Medium dense, NOTES: 1• The Percolation Soil Profile Pit was excavated on May 23, 1995 with 2• No free a backhoe. ground water was measured at the time of excavation. 3• The Percolation Soil and limitations Profile Pit is subject to the explanations, conclusions as contained in this report. LOCATION OF PERCOLATION SOIL PROFILE PERCOLATION TEST RESULTS HOLE NUMBER DEPTH OF HOLE INCHES TIME ELAPSED TIME INTERVAL MINUTES DEPTH TO WATER START OF TIME INTERVAL INCHES DEPTH TO WATER END OF TIME INTERVAL INCHES CHANGE IN WATER DEPTH INCHES PERC RATE MIN/INCH K0ECHLBNCONSULTING ENGINEERS PERCOLATION TEST RESULTS HOLE NUMBER DEPTH OF HOLE INCHES TIME ELAPSED TIME INTERVAL MINUTES DEPTH TO WATER START OFTIME INTERVAL INCHES DEPTH TO WATER END OFTIME INTERVAL INCHES CHANGE IN WATER DEPTH INCHES PERC RATE MIN/INCH P-2 40 ---- 10 20 24 4 2.5 24 26 2 5 26 29 29 31 2 5 31 32 1/2 1.5 6.7 32 1/2 34 1.5 6.7 34 34 5/8 .625 16 34 5/8 35 1/8 .5 20 35 1/8 35 3/4 .625 16 35 3/4 36 3/8 .625 16 36 3/8 37 .625 16 KOECHLEIN CONSULTING ENGINEERS D D D PERCOLATION TEST RESULTS HOLE NUMBER DEPTH OF HOLE INCHES TIME ELAPSED TIME INTERVAL MINUTES DEPTH TO WATER START OFTIME INTERVAL INCHES DEPTH TO WATER EN , D OF TIME INTERVAL INCHES CHANGE IN WATER DEPTH INCHES PERC RATE MIN/INCH P-3 28 ---- 10 7 10 3 3.3 10 13 3 3.3 13 15 2 15 16 1 10 16 16 1/2 .5 20 16 1/2 17 .5 20 17 17 1/2 .5 20 17 1/2 17 3/4 .25 40 17 3/4 18 1/8 .375 27 18 1/8 18 3/8 .25 40 18 3/8 18 5/8 .25 40 0 KOECHLEIN CONSULTING ENGINEERS P 777 A m