HomeMy WebLinkAbout565 Lariat Loop - 210505402011 - 1815-98ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1815-98 BP NO. 12218
OWNER: KURT BROSIG PHONE: 970-926-2150
MAILING ADDRESS: P.O. BOX 146. EDWARDS. CO 81632
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 565 LARIAT LOOP EDWARDS. CO TAX PARCEL NO. 2105-054-02-011
LICENSED INSTALLER: STENSON EXCAVATING. BILL STENSON LICENSE NO. 34-98 PHONE: 970-926-3849
DESIGN ENGINEER: LKP ENGINEERING LUIZA PETROVSKA PHONE NO. 926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON TWO COMPARTMENTSEPTIC TANK 563 SQUARE FEET OF ABSORPTION AREA VIA 18 INFILTRATOR UNITS AS PER DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 8/10/98. ENGINEER TO FIELD VERIFY SOIL PROFILE AT TIME OF
INSTALLATION. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED
WITHOUT FINAL APPROVAL OF SEPTIC SYSTEM.
ENVIRONMENTAL HEALTH APPROVAL: DATE: SEPTEMBER 8 1998
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2, THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 863 SQUARE FEET (VIA INFTLTRATOR TTNTTS , IS )
INSTALLED CONCRETE TANK:.1 000 GALLONS IS LOCATED _ DEGREES AND _ FEET FROM
SYSTEM WAS INSTALLED 10 FEET CLOSER TO RESTDFNCF THAN TNT)TCATFTI nN GITE PLAN
COMMENTS: ENGINEER FINAL CERTIFICATION RECEIVED 5-10-99
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
if /
ENVIRONMENTAL HEALTH APPROVAL /--� �� `� DATE: MAY 17, 1999
Incomplete Applications Will NOT Be Accepted
(,,,, plan MUST be attached)
ISDS Permit # lif f—gw
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS: PHONE
APPLICANT/CONTACT PERSON: PHONE: 2- 2-1
LICENSED SYSTEMS CONTRACTOR:
COMPANY/DBA: ADDRESS:
PHONE:
PERMIT APPLICATION IS FOR: (,/rNEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL
,a /
Legal Description: J-&-f q —
Tax Parcel Number: 4(05--
5(e -
Physical Address. —
BUILDING TYPE: (Check applicable category)
Residential/Single Family
Res4Ldential/Multi-Family*
Commercial/Industrial*
SYSTEM:
M
-� � t
Lot
,///I?q 1
Size : 6 -Y' ,
Number of Bedrooms
Number of Bedrooms
Type
TYPE OF WATER SUPPLY: (Check applicable category)
Well ( ) Spring ( ) Surf ace,-
Public Name of Supplier: w)
*These systems require design by a Registered Professional Engineer
SIGNATURE: Date: b
AMOUNT PAID: I SD. RECEIPT #: DATE:
CHECK #: CASHIER:
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: September 8, 1998
TO: Stenson Excavating
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1815-98. Tax Parcel
# 2105-054-02-011. Property Location: 565 Lariat Loop, Edwards, CO., Brosig
residence.
Enclosed is your ISDS Permit No. 1815-98. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
May 17, 1999
Kurt Brosig
P.O. Box 146
Edwards, CO 81632
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1815-98, Tax Parcel #2105-054-02-011. Property location: 565
Lariat Loop, Edwards, CO.
Dear Mr. Brosig:
This letter is to inform you that the above referenced ISDS Pen -nit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
jmd/ ��
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
05/10/113139 09:39 970-926-9089 LKP ENGINEERING, INC PAGE 01
Engineering, Inc.
L
crvruciVoTEa0aCAL
May 2, 1999
Mr. Kurt Brosig
P.O. Box 146
Edwards, CO 81632
Dear Kurt,
RE: Inspection or septic System Installation
Lot R- 13, South Forty Subdivision
Eagle County, Colorado
Project No. 9812 - Permit No. 1815-98
At your request, on April 23, 1999, we visited the construction site on Lot R- 13, South Forty
Subdivision, Eagle County, Colorado. The purpose of our site visit was to observe the installation of the
septic System.
They installed the system in overall compliance with the septic system design, Drawing No.
98121 SD.DWG, dated August 10, 1998. The system was installed as shown on the above named drawing;
except it was about 10 feet closer to the residence. They installed 1000-gallon, two compartments, -a
precast, concrete septic tank. The tank had risers on both inspection covers. Those are not necessary and
should be removed. From the tank to the first Infiltrator trench was 10 feet.—'
Eighteen Standard Infiltrator Chambers were installed in two trenches with 9 Infiltrators cacti. -The
infiltrators were connected with serial distribution. In the last infiltrator of each trench, inspection polls
will be installed. Horizontal distance from center to center of the trenches, was 9 feet. All piping was SDR-
35, 4-inch PVC -I -he depth of the trenches was two to three feet, two feet near the house and three feet on
the east end -:-The soil profile in the trenches was consistent with the soil described in the report by Inter -
Mountain Engineering, LTD.
If you have any questions, please do not hesitate to call.
Sincerely,
LKP Engine
u i Zr
za PetI
President
cc; Ms- Heather Savalox, Eagle County Environmental Health Division, fax: 328-7185
C.11OFF;cFkwpwrNI%WFDOCS%9612105twpr)
P.O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax, E-mail- lkpeng@snowcap.net
"JOP D.I. f 1 DD 0 /-1 . �u Lr\r =1NU11N=K1NL1, INN tIAUF U1
LIK? mir "E"N G WEE EEC NT G ZINC.
FA Box 2837
Edwards, CO 81632-2837
(970) 926,9088
Fax (970) 926-9099
Uotation: Lot R-13, South Forty Subdivision Client: Mr. Kurt Brosig
Eagle County, Colorado P.Q. Box 146
Septic System, for the Brosig Residence Edwards, CO 81632
Project No.:
TMODEPTH
98-121
P-1
34-10/16"
P-2
P-3
38-9/16"
10
25-4116"
1-6116"
14-10/16"
3-14/16"
16-4/16"
10
12/16"
18"
1- 14116"
36-12116" 20-8/16"
added water
130
10
26-12/16"
12/161
19-8/16"
1-8/16"
17-12/16"
10
27-12116"
1"
20-8/16"
lot
36-8/16" 5-12/16"
10
28-8/16"
12116"
empty
10
29-4/16"
22-8116"
10
30"
12/16"
23-8116"
PERC RATE
13.3 MINANCH
10 MWINCH
1.7 NUN/TNCH
AV PERC
8 NWMS PER INCH
*** Last Pere Rate used for calculations
Average Percolation Holy .Diameter: 8 Inches
Holes Dug and Prmakc&August 4.1999
Test Run: August 5, 1998
Moat -its Fax Note 7671
Oat$ 9
$10. 1
TO flzdbf;c 5341 OW
From
FINkM& -
P en
tiff i 114
7one #JD,f
pt-'One it q�6-
q08?
Fax
Fax
08/30/1999 21:31 970-327-9089 Lk:P ENGINEERING, INC PAGE 01
Post-4111 Fax Note
Ntm
PERCOLATION TEST RESULTS
AND SEPTIC RECOMMENDATIONS
FOR
LOT R-13, SOUTH FORTY SUBDIVISION
FAGLE CIOUNTY, COLORADO
PRLPARED FOR:
r
PROJECT NUMBER V-11090
MAY 1981
Box C-100
AVON, CO 81620 1420 VANCE STREET'
042-5072; DENVF.R Ami4qi LAKEWOOD. CO 80215
08/30/1998 21:31
SCOPE
LKP ENGINEERING, INC PAGE 02
This report presents the results Of a percolation test
and provides septic system recommendations for the proposed
residence located on Lot R-13, South Forty Subdivision, Eagle
County, Colorado,
SITE LOCATION AND DESCRIPTION
The site is 10cated In a part of the Southeast one -quarter
of Section 5, Township 5 South, Range 82 West of the Sixth
Principal Meridian, Eagle County, Colorado. More part!-
CUlarly, the site, Is described as Lot R-13, South Forty
Subdivision.
The site drain to the north and vegetation consists of
sage brush and native grasses. -
SUBSURFACE AND GROUNDWATER CONDITIONS
Subsurface conditions are fairly uniform with topsoil
to a depth of one foot underlain by
clayey,
moist, light brown.. Additional Soils Information may be
found in the "Soils and Foundation Investigation" for this
site by I ' nter•-MOumfain-Engineering, Ltd., Project Number
V-1110G# dated May 198(.
08/30/1998 21:31 970-827-90e9 LKP ENGINEERING, INC PAGE 03
2
PERCOLATION TEST RESULTS
A total of three percolation tests were Performed on
the site using the Standard test method as described by
the Eagle County Individual Sewage Disposal System Requiations,
The test holes were dug by the client. The test holes were
presoaked on May 5, 1981, and the test was performed on May 6,
1981. The results were as follows:
Test Hole No. Min./I" �kro Depth of Hole
1 5 min.,,10 sec. 4811
2 6 min., 30 sec. 4811
3 6 min., 30 sec. 36TO
Time used for design; 6 min., 30 sec,
DESIGN CRITERIA
The house will have threebedroomsand will include a
garbage grinder and automatic washing machine. Assumptions
used in th-e calculations were:
Three bedrooms with garbage grinder and automatic
Wash ln9 machine.
2 persons/bedroom
73 ga.1 lons/person/day
Maximum flow! 150% of average daily flow
08/30/'1998 21:31 970-e27-90e9 LK'P ENGINEERING, INC PAGE 04
3
Calculations: -Y T
A = Q
—3—
where A = minimum absorption area (sq. ft.)
Q = estimated quantity of sewage flow (gal/day)
T z; percolation rate (Min/inch)
Q = 2 x 3 x 75 x 1.5 = 675 gal/day
675-V6.5
A = 5 344 sq. ft.
Absorption area to be increased 20% for a garbage grinder
and 40% for tl�o automatic washer (County Regulation 8.1 e).
344 x 1.60 = 551 sq. ft.
Since a seepage bed Is to be used, the absorption area
is to be increased by an additional 30% (County Regulation
8.1 h ) .
551 x 1.30 = 716 sq. ft.
Due to subsidence problems in this area, the seepage bed
should be increased by another 30%.
716 x 1.30 = 931 sq. it. - Use IS x 52 = 9.36 sq. ft.
Adjusting the length of the absorption be,d for acid l"tional
gravel depth (County Regulation 8.1 1), for one foot of addi-
tional gravel:
Length = 52 x 48+1+2
= 50 ft.
SIZE Or SEEPAGE BED = 18 feet x 50 feet.
From Table 4 (Section 7.1 of the County Regulations),
the
Minimum tank size shall be 1000 gallons.
08/30 1998 21: 31
970-827-9089 LKP ENGINEERING, INC PAGE 05
SEPTIC SYSTEM RECOMMENDATIONS
Based on the preceding calculations, recommendations are
for a minimum of a 1000 gat Ion compartmented septic tank to
be foliowed by a minimum 936 square foot seepage bed. The
bed should lie a minimum of ten feet from property lines and
twenty feet from the proposed residence. Inspection of the
system should be made by a representative of Inteir-Mountain
Engineitaring, Ltd., and by a representative of the Eagle County
Environmental Health Department prior to backf IA I Ing.
Excerpts from the Eagle County Individual Sewage Disposal
System Regulations have been included as Appendix A. The
Installation and matsrl6l specifications in these regulations
Must be followed.
!CaHCLUS IONS
Th is report has been prepared for the exclusive use
of Kurt Brosig for the specific application to the proposed
residence located on Lot R-13, South Forty Subdivision, Eagle
County, Colorado.
The finding's and recommandattons of this report have
teen. obta,lned in accordance with - accepted professional engi-
neering practices In the field of Foundatlon Engineering
and Soil Mechanics. There is no other warranty, either
08/30/1998 21:31 970-827-9089 LKP ENGINEERING, INC
PAGE 06
CONCLUSIONS - continued
W
express or impi led
If we can be of further assistance, please do not
hesitate to call.
Sincerely,
INTER -MOUNTAIN ENGINEERING, LTD.
G. 0mas Allan
Field Engineer
%OR I a Reviewed and�pproved By;
44-MAt, N
alp
i7_,�
1p, 0-0 , " i f 1, PE
Je ry S
to 1 0
0091VAL V ce P es d�qnt
op co�_
1815-98 Tax# 2105-054-02-011
JOB NAME Lot R-13, South 40 BROSIG JOB NO. E-
565 Lariat Loop
Edwards
( 50 LOCATION 0
A
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
Av-
,F131 I -a, d
bv. 71t5
dW so;ls .5,'li a &o 1-14 �,14 /-I
eL &V{
r
,
U
/VO/ IMP
W111-11'Af
L ho q
Z,4P
bnll /-vy
VO�
JOB FOLDER Product 277 JOB FOLDER
Y,<crY Eagle County OMITS Systems Cleaners Reporting Form
NOTE: Required to be submitted to Environmental Health within 10 days of cleaning an OWTS system
Systems Cleaner Company License Number
Email Address �+ IVI Phone
Service Technician Phone
Tax Parcel # Address of Service �3 cti— L (4 tVvCLv- �
Person Requesting Serviced Phone��y���Z�
Property Owner �k\`M �� Phone C V�0\
Septic System Permit Number �1L _ Tank Size __ Vy)n cul 1r�(
Date of service d Tank Material
Sewage Disposal Site _ -�N-�v"'1&
General Condition and Functionality of the Syster �! Y
Recommended Repairs
Site sketch showing location of the septic tank access lids measured from at least 2 fixed points
(Photos Encouraged)
Signed _ Date 151261C
DETAIL A
N.rs
0
LARIAT LOOP
INFILTRATOR CHAMBER
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
1 inch = 20 !t
W
10 0 0 GALL ON CONCRETE SEP TIC TANK
BY COPLAND CONCRETE OR EQUIVALENT
TOP ViEW
U
SIDE VIEW
6'
PERGOLA T70N TEST RESULTS
Perc No. 1 Perc No. 2 Perc No. 3
13 minutes per inch 10 minutes per inch 2 minutes per inch
Average percolation rate recommended for design T = 8 minutes per inch.
Soil profile data provided by Infer —Mountain Engineering, Ltd in a Percolation
Test Results and Septic Recommendations, dated May, 1981, Project No.
V-1190G 2
SOIL PROFILE V301,� �
PROFILE MOLE
0.0 to 1.0 foo t Topsoil
over Clayey Silt
lGN CALCULATI
Design percolation rate T = 8 minutes per inch
Number of bedrooms = 3
Maximum daily Flow = Qmox
Qmox = 3 bdrms �y 2 persons/bdrm x 75 gallons/person/day x 15OX
Qmox = 675 gpd✓
SEPTIC TANK
V = Qmox/24hrs x 30 hrs
V = 844 gallons
Use 1000 gallonitwo compartment precast concrete tank by Copland Concrete or equivalent
ARSORP77ON AREA
A=Qmax5xVT
A = 67515x V18 = 382 s. f.
Amax = 382 s f.
Based on Applicatio Rate:
A = 675gpd 11.2 gpd/s f.
A = 563 s f.
Standard Infiltrator Chamber System in a trench configuration with an allowed 50 percent
reduction in the absorption area is recommended.
Amaximum = 282 s f.
Surface area of one Infiltrator Chamber = 15.5 s f.
Use 18 Infiltrator Chambers in two trenches with 9 Infiltrators in each.
0 S:
1. The building sewer line from the house to the septic tank shall have a maximum slope of 114 inch per
foot. Bends in the building sewer shall be limited to 45 degrees.
2. The septic tank shall be installed level. The tank shall have removable covers or manholes to within 8
inches of the finished grade, for inspection and cleaning.
J. Excavate three (3) feet wide trenches. The horizontal distance from sidewall to sidewall between the
trenches shall be a minimum of six (6) feet.
4. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing.
5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers
recommendations.
6. Backfill the sidewall area with native on --site soft for proper support.
7. Backfill the trenches with a minimum of 12 inches of tamped soil cover.
8. Avoid vehicle traffic over the system.
9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division,
Chapter 4, Individual Sewage Disposal Syste,•ns.
10. The Septic System Installation shall be inspected by the Design Engineer prior to backfilling.
STANDARD INFILTRATOR
NOTE.• SITE PLAN PROVIDED BY MR. BROSIG.
o I I
Im
rn
art
;4
M I
W
I--- N
W Cn
01,1
U
wo)
L
v X
o
4
W
00
ao
t j
00C14
j
to
U
•
x N
rn
P
m .-
i N BY- L.P.
CHECKED BY- L.P.
PROJECT NO.: 98121
DA1F• 8-10-98
DRAWVG NO.: 98121SD.DWG
SHEET 1 OF 1
�rrr
YF
K&T
A
f
2c CIE- E:
THEE
you � v C-jo\ir,- a-
p5v-EQIIXLl5
cof ic EE PT u -4 1-
P E PLC
L c)-T 2- 1 -:fJ
sou-r(4 FrCTT SCA&DNISP1`4
( 0 c:::, 20 1