HomeMy WebLinkAbout630 Cordillera Wy - 210712203015 - 1712-97ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1712-97 BP NO. 11402 OWNER: DAVID TEMIN PHONE: (970-926-4329) MAILING ADDRESS: P.O. BOX 599 EDWARDS, CO 81632 APPLICANT: BILL GRAY, P.O. BOX 599, EDWARDS, CO 81632 PHONE: (970) 926-4329) SYSTEM LOCATION: 0630 CORDILLERA WAY, EDWARDS, CO TAX PARCEL NO. 2107-122-03-015 LICENSED INSTALLER: STENSON EXCAVATING, BILL STENSON, P.O. BOX 876, EDWARDS, CO 81632 LICENSE NO. 25-97 DESIGN ENGINEER: INTER MOUNTAIN ENGINEERING, RICHARD RICKS PHONE NO. (970)949-5072 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 2000 GALLON SEPTIC TANK 1705 SQUARE FEET OF TRENCH ABSORPTION AREA, VIA 55 INFILTRATOR UNITS AS PER DESIGN. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 6-10-97, INCLUDING AN EFFLUENT FILTER ON THE OUTLET TEE OF THE SEPTIC TANK, WHICH SHOULD BE CLEANED IN ACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION OF THE INSTALLATION. BUILDING CO WILL NOT BE ISSUED WITHOUT ENGINEER CERTIFICATION. ENVIRONMENTAL HEALTH APPROVAL: DATE: JULY 23, 1997 CONDITIONS: _.....___-- __.._.__-- 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1706 SQUARE FEET (VIA 59 i n f i l t rn I- n r n n i tg ) INSTALLED septic TANK: 2000 GALLONS IS LOCATED DEGREES AND FEET FROM See site plan for location of system. COMMENTS: Engineer final certification received 10-8-97. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: n r i- oh e r 9, 1 9 9 7 (Site Plan MUST be attached) 4� ISDS Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************* PROPERTY OWNER: �U+` 1� t �t*� PHONE: MAILING ADDRESS: �' Q�t' �;QCG ■IC1 n175 Cis , APPLICANT/CONTACT PERSON- `aZ PHONE: MAILING ADDRESS: t S 5 �?—� r, 3z- LICENSED ISDS CONTRACTOR: � \ S�l"eAwlriln 2�hj PHONE: ( ) COMPANY/DBA: ��,` ADDRESS: ************************************************************************* PERMIT APPLICATION IS FOR: (1�New Installation ( ) Alteration ( ) Repai ************************************************************************* LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # Legal Description: ( if known) Subdivision: t Filing:_Block: Lot No: Tax Parcel Number: `-� -�-- ►�" Lot Size: Street Address:?lt� BUILDING E: (Check applicable category) (VIYP Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* Number Number Type _ TYPE OF WATER SUPPLY: (Check applicable category) ( ,.) Well ( ) Spring ( ) Surface ( Public Name of Supplier: 1br1't__ *These systems require design SIGNATURE: ********************************* of Bedrooms of Bedrooms a Registered Professional Engineer TO BE COMPLETED BY THE COUNTY AMOUNT PAID: �,.�Zi��. RECEIPT CHECK #: Date: 1 ~ t #:A � 1 G DATE: I l C 7ST3 CASHIER: Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: July 23, 1997 TO: Stenson Excavating Eagle County Building P.O. Box 179 -.00 Broadwav Eagle. Colorado 81831-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1712-97. Tax Parcel # 2107-122-03-015. Property Location: 0630 Cordillera Way, Temin residence. Enclosed is your ISDS Permit No. 1712-97. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Inter Mountain Engineering, Richard Ricks Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 October 9, 1997 David Temin C/O Signature Homes P.O.'Box 599 Edwards, CO 81631 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit No. 1712-97, Tax Parcel #2107-122-03-015. Property location: 0630 Cordillera Way, Edwards, CO 81632. Dear Mr. Temin: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files K ter-Mountain Engineering Ltd. October 6, 1997 Bill Stenson Stenson Excavating PO Box 876 Edwards, Colorado 81632 RE: Septic System Inspection Lot 5, Cordillera Subdivision Filing No. 1 & 2 Eagle County, Colorado Project No. 97-0264G Dear Bill: The undersigned visited the subject site to inspect the installation of the septic system for the residence to be located at Lot 5, Cordillera Subdivision Filing No. 1 & 2. The site was visited on July 29, 30 & 31, 1997 to observe the installation of the septic system infiltrator absorption field. The absorption field was installed prior to the construction of the residence because of the lot layout. On September 3, 1997 the site was revisited to inspect the installation of the septic tank. The septic tank consisted of a rectangular 2000-gallon concrete septic tank. The absorption field consisted of 55 infiltrator chamber units installed in 5 rows. L-7 �fl� The septic system was installed in substantial compliance with our design dated June 10, 1997, Inter -Mountain Engineering Project No. 97-0149G. This document was prepared for the exclusive use of Stenson Excavating. The use of this document or the information contained herein by any other person or entity is not authorized. In the event any other person or entity desires to use this document for the information contained herein for any purpose, they must first contact Inter -Mountain Engineering for written authorization Res ec p :a ichar O. Ricks, R _ Geotechnical Engizeer,'•�, cc: Si ature Homes 1 ���" ^; x'� :, `�������`\\\• 4�I�� Eagle County Envi�i���u1rronme ealth G:\engineer\soils\letters\bs septic insp 77 Metcalf Road, #201 • Box 978 • Avon, Colorado 81620 • Phone: 970-949-5072 • From Denver Direct: 893-1531 1420 Vance Street • Lakewood, Colorado 80215 • Phone: 303-232-0158 WL. J` L -) f UUf71 :3 Cj J MAUL U1 . . . . . . . . . . JWY-22, 1997 -Ar*tsNlcknish 8"Oure Homes 'PO sox $99 EdwArdS, CO 81632 RE: Percolation Testing Lot 5, Cordillera Subdivision Filing No. I & 2 Eagle County, Colorado Project No. 97-0149G Door Ms. Nicknish: I Inter-Mountaln Engineering performed a septic system design for the subject proJect - n order to design the septic system a profile hole was dug and percolation testing was performed. Th.0 percolation tests were performed on May 20, 1997 in the vicinity of the proposed 0800ption field, refer to septic System. Three 6-Inch diameter percolation test holes were dug to depths Of approximately 30 inches. The test holes were filled with water 24 hours prior to the actual testing to allow the soils to inundate. The water levels were measured to a relative constant rate. The Percolation rates varied from approximately 17 to 30 minutes per Inch. The results of the percolation are attached. The soils encountered in the profile hole - nsisted of a light brown sandy SILT and SILTSTONE gravel to depths of approximately �Eofeat. Afthough the percolation test holes and profile pits were dug to obtain a reasonable accurate determination of the absorption field conditions, variations in the subsurface condifloms are 816b possible. Variations that exist beneath the absorption field may become evident during the excavation. A representative from our office should observe the completed excavation to confirm that the soils encountered are as Indicated by the soils profile hole. Should you have any questions, please contact the undersigned, P Richard 0. Ricks, P. Gootechnical Enginq '00; Laura Fawcett GAM 10Ff*"r*AWd11fi,'*r*AdnV0J 44 OW ng Department 77 WOO %ad, #201 ® BOX 978 * Avon, Colorado 6162() 0 Phone, 970,949-5072 ® From Denver direct: 89341531 1420 Vance Street 9 Lakewood. Colorado 60215 o Phone- 303-232-0158 CJf/LLF I 'J'Z t UZ ; .J (4 uo f•jl.�Ud PAGE 02 03 R P S� x S � 3 - t r! . B` 4 rT4 s3. P "u i £ >s^ t >� f .:3 3 k { SE24 P "13 % r GROUND SURFACE l 3' INf7L T TA TOR CHAMBER. (T ) ALL CHAMBERS ROWS 70 BE ----- t INSTALLED LEVEL 1.5' MIN t 4" PVC Hfl7N SHEEP 90's or 45's __--- 4' MIN. TO BEDROCK or GROUNDWATER SERIAL INFIL TRA TOR INS TALLA TON NOTE. SEE CONSTRUCTION NOTES FOR INS TALLA 77ON REQUIREMENTS Not To Scale .. -. _T.c�:'-., T' :,,,y.:--^-' ..: ,;`-,.�,a _>os—,ni.. ^�,G ram:.`-'"P'':"R"re�' '."-•nr"'._ .'e '( '� �.... _t _d. ..-�- I, '77 'F! ,fivz , y � -' � ,:' , ;M ....: M :.>:�:` .,z `. k. s i a�y� -,. ; k � :sr'�'�' _.. r x: k �" g :� '� S �•, '6 '� ':p•�� , h :"x '# '� � �;: �.`* "a '-� J SANDARD INF-1 TRA TOR CHAMBER Nat To Scott 2000 Gal. Two Compartment FLXX Septic Tangy F Note, N.T.S PLAN • MONC?LITHIC TANK \ 6' B' meets ASTM-C-913 1 ' Spec: for water and CL t waste water strue Lures. i • Butyl rubber sealant 4 meets Fed. Spec. SS-S- Il j 210A. (Optional per requirement.) • Plumbing shown in I - ---- 4_.._. diagram provided with tank. ■ It is the system engineer's 2 t dear Insert access require- ment to determine SECTION /1 VOLUME, LOADING-4 and RETURN TIME.Pi 4 r A 1 55. 52" ( � i Oreneo Systems' tncotporated Et4 AMWAY AVENUE SuTHERLIN OAMQN 174 N I-117 t€tEW' t50 455 444 i FACSIAMtf M314511M osl BiotubeTM Effluent Filter P 0 IF 10t"50y S,ntun0_ Co "dh US. Mee" of um Pa mNo. 4MM Dimensions Capacities pafton.) A B Approximate Weights W L H Tank Lid Baffle Walls Total 5-]0" ]�25 675 1],725 5,520-]bs 14401bs 1'c,7B5ibs� tbs dicat�ons Dimensions FT0444-36 A Nominal Diameter 4" Extendible PVC Handle B Vault Height 44' PVC Cap C Invert Height 38' DDInvert to inlet Height 16' ' Air Vents E Inlet Hole Height 22" F Filter Area (f0 5.3 Sealing Ring Custom saes available. Call for assistance. 1,,8" Mesh Polypropylene Tubes -A with Solid Base TT olvent Weld } Tee i -ity pipe 0.0.1 (� B I t Housing 1 118- Diameter r !tholes � E i l ! install a Biotube Effluent Filter in the septic tank in accordance with manufactures recoomendations. We reccomend OSI System Biotube, or equivalent. Biotube should be cleaned in accordance to manufactures reccomended schedule. 2 GRAPHIC SCALE CON57NIJC77ON NOTF'S.• -()l 1, Sewer line from house to septic tank shall have o � () slaps of 1/4' per foot. 2. Bends in building sewer shall be limited to 45 degrees. J. Septic tanks shall be installed level. the Tanks are to have removable cover or manholes to within 6 inches of 6nfsh grade for access to each compartments, .for cleaning and inspection. Septic tank. to meet all the requirements of Eagle County Individual Sewage Disposal Systems, Section 4.07. The tanks ore. not to be located beneath designated driveways. 4. Excavate and level 3 feet wide trenches, 2.5 feet deep, and 6 feet apart r s 5. Prepare trench bottom and sides in accordance .with the state Wit' and local regulations. (Fos the lnfi/trator System, raking sidewoll and bottom infiltrative surfaces is necessary to reduce smeoring.) 6. Assemble .and install the Infiltrator Chambers in the Trenches according to the manufacturers recommendations. 7. 8ack6!l the .side wa!/ area with native soil for proper support. 8. Backfi/l the trenches with a minimum of 12 inches of tamped SOi/ co ver. 9. Avoid vehicle traffic over the system. 10. Ai! installations shall meet the rules and regulations of Eagle County Environmental Health Division as set forth in the Individual Sewage Disposal System regulations .Construction of the system shall be inspected by the Engineer, prior to backfilling. 11,E"SIGN FLOW Design Percolation Rate, T= 22minute per inch Number of bedrooms = "-'' Maximum doily flow = Qmax Qmax = 6 bans x 2 persons/brm x 75 gallons/person/day x 150X Qmax = 1.350 gallons per day T7C TANK V = 4max x 30hrs 24hrs V = 1350 x 30 = 1690 gallons VA 2,000 gal/an, two comportment septic tank is required. A0ORP7701Y AREA -Calculated as a function of design flaw (Q) and Lang Term Acceptance Rate (LTAR) A = Qmox/L TAR L TAR for 20 Minfinch is .8 � � A = 1350/. 8 = 1688 ft 2 Use an absorb tion area (Amax) of 1690 sg, ft. lnffltrator Chamber System in o trench configuration is recommended with an allowed 5071, reduction in the required absorb tion area. 0.5 Amax = .5(1690 sq, ft.) = 845 sq. ft. sr, Surface area of one inhltrotor chamber = 15.5 sq. rfi.- Use 55 in6ttrator chambers, SUBSURFACE SOiL CONDlT7ONS Soil ProF/e 0-2' Topsoil and Blackish SILTS 2-8' SILT, Sandy, Lt. Brown, with siltstone gravel. Test pit. terminated at 8'. No measurable groundwater reported. Bedrock not encountered. ` GENERAL NOTES 1. Percolation Test Results and Subsurface Soil Conditions obtained by Inter -Mountain Engineering Ltd 2. It is recommended that the trenches be excavated to a minimum depth of 36 inches. A minimum cover of 2' shall be maintained over the top of the infiltrator chambers. J. Topographic information and lot layout provided to Inter -Mountain Engineering Ltd., by Robert Arnold, Architect, P.C.. Denotes Percolation Test Pit Approximate Location - Denotes Approximate Location of So# Profile Test Pit NOTE.• IF DURING CONSTRUCTION OF THE LEACHFIELD, SOLID OR FRAGMENTED BEDROCK IS ENCOWERED, THE ENGINEER SHOULD BE CON TAC TED IMMEDIA TEL Y FOR ADDI TIONAL RECOMMENDA 77ONS. �r Ilil (, P. D. BOX 978 nlnrt r 51117E ET 00TT M£TCAI F ROAD �+� • LAXEIN, yCQO.3 80215 Q��a`a O• l A'T �i (9 99-5072� iginei L" (30J) 232-0158 Q x 3043 - SEP77C SYSTEM DESIGN s 0149G ® • ` orinrw er: oA� asuto: SION //iurnul►t►�a��`` ROR CORDILLERA FILING NO. 1 & 2 1' = 20' BK/35' EAGLE COUNTY COLORADO OF 1 ( IN FEET ) 1 inch = 20 ft. DATE REVISIONS