Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout1204 Daggett Ln - 211119100003Work Classification: NewPermit
899 DAGGET LANE
GYPSUM CO 81637-
Address Owner Information
Permit Status: Active
Project Address
211119100003
Permit Type: OWTS Permit
Permit NO. OWTS-8-13-9546
Expires: 1/2/2014 Issue Date: 9/4/2013
Parcel No.
1204 DAGGETT LN
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)471-1021
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)471-2121BROCK CONSULTING, LLC
Contractor(s)Phone Primary ContractorLicense Number
BROCK CONSULTING LLC (970)328-2123 Yes29-13
LAURA AND STEVEN HAGEN
Permitted Construction / Details:
This Brock Consulting, LLC engineer design resubmittal dated September 4, 2013 has a tank sized for up
to 5 bedrooms, but the leach field is only sized for 3 bedrooms. Install per design a 1500 gallon, two
compartment concrete septic tank with a cleanout between the dwelling and the tank. Use schedule 40
PVC and insulate under the driveway and any parking areas with 2” rigid insulation. The absorption field
is to consist of 28 Quick 4 Infiltrator units in two trenches to provide 560 sq ft of absorption area credit or
an actual area of 280 sq ft. Trench should follow the natural surface contours and be level. Rake trench
bottom and sidewalls to eliminate smearing and remove any cobbles in trench bottoms and in backfill
material. Provide inspection portals at each end of the trench.
Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call the design engineer
for a final inspection before burying any of the system components. In order to receive final approval, the
engineer must provide the final certification letter, photos of the installation, and as-built drawings of the
system.
Issued by: Environmental Health Department, Eagle County, CO
September 04, 2013
Date
Customer Copy
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification: NewPermit
899 DAGGET LANE
GYPSUM CO 81637-
Address Owner Information
Permit Status: Active
Project Address
211119100003
Permit Type: OWTS Permit
Permit NO. OWTS-8-13-9546
Expires: 1/2/2014 Issue Date: 9/4/2013
Parcel No.
1204 DAGGETT LN
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)471-1021
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)471-2121BROCK CONSULTING, LLC
Contractor(s)Phone Primary ContractorLicense Number
BROCK CONSULTING LLC (970)328-2123 Yes29-13
LAURA AND STEVEN HAGEN
Permitted Construction / Details:
This Brock Consulting, LLC engineer design resubmittal dated September 4, 2013 has a tank sized for up
to 5 bedrooms, but the leach field is only sized for 3 bedrooms. Install per design a 1500 gallon, two
compartment concrete septic tank with a cleanout between the dwelling and the tank. Use schedule 40
PVC and insulate under the driveway and any parking areas with 2” rigid insulation. The absorption field
is to consist of 28 Quick 4 Infiltrator units in two trenches to provide 560 sq ft of absorption area credit or
an actual area of 280 sq ft. Trench should follow the natural surface contours and be level. Rake trench
bottom and sidewalls to eliminate smearing and remove any cobbles in trench bottoms and in backfill
material. Provide inspection portals at each end of the trench.
Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call the design engineer
for a final inspection before burying any of the system components. In order to receive final approval, the
engineer must provide the final certification letter, photos of the installation, and as-built drawings of the
system.
Office Copy
September 04, 2013
Issued by: Environmental Health Department, Eagle County, CO Date
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
8-13-9546
$800 600715 1001 08/28/2013
BROCK CONSULTING, LLC
Professional Services
November 14, 2013
VIA email: [environment@eaglecounty.us]
Eagle County Building Department
P.O. Box 850
Eagle, CO 81631
HICLLC
876 Mesa Drive
P.O.B. 3644
Eagle, CO 81631
Direct 970-471-2121
Fax 970-328-087S
brockconsulting@centurytel.net
Reference: Engineering Certification Letter for Hagen/Gerard Residence
Permit # OWTS 8-13-9546
1204 Daggett Lane, Gypsum, Colorado
Dear Department of Environmental Health:
Please accept this certification letter, as -built drawing and pictures as certification of the
OWTS serving the residence at 1204 Daggett Lane, Gypsum, Colorado in Eagle
County, Colorado has been installed as reflected on the As Built Drawing, attached, and
constructed per Eagle County Septic Regulations by licensed septic installer Vern L.
Brock (license #29-13) and general contractor/owner Hagen/Gerard.
If you have any concerns with this submittal, please call me.
Sincere
Vern L. Brock, P.E.
Brock Consulting, LLC
cc: Steven Hagen, Doug Hill
Attachments: AS -BUILT DRAWING, 11/13/13
Actual dimensions to Facilities, 11/13/13 o,*,D0- LICF,y
Progress Pictures of 11-11-13 1-
3
o�Fss�0 A
HAGEN/GERARD RESIDENCE OWTS # 8-13-9546 PROGRESS PICTURES
1204 DAGGETT LANE, GYPSUM, COLORADO
DATE 11-11-2013
CLEAN OUT AT HOUSE WEST SIDE, 32 FT FROM NW CORNER
SEPTIC TANK (COPELAND 1500 GAL) OUTLET PIPE WITH PROPRIETARY SCREEN)
Page 1 1
MAIN LINE, 4 INCH PVC (SDR 35) AT 2% TO INFILTRATOR TRENCH 1
CONNECTION AT TRENCH 1 PER PRE MANUFACTURER INLET PORT
Page 1 2
_ 1`
idtf L;
$ g
�,. ' w
-44
UPPER TRENCH #1 LOOKING NORTH EAST, DEPTH 3 FT., LEVEL
Page 13
LOWER INFILTRATOR TRENCH; TYPICAL CHAMBER DEPTH 3 FT; ROCKS SCREENED FROM ALL BACKFILL
OF SEPTIC SYSTEM !
TYPICAL PIPE SPECIFICATION SDR 35, 4 INCH; TRENCHES LEVEL
TRENCH SIDES —TYPICAL; ROCKS REMOVED FROM BEDDING
Page 14
BROCK CONSULTING, LLC
ACTUAL DIMENSIONS TO FACILITIES
SEPTIC TANK TO BUILDING
SEPTIC TANK TO WATER LINE
SEPTIC TANK TO ABSORPTION TRENCHES
SEPTIC TANK TO WELL
ABSORPTION TRENCHES TO BUILDING
ABSORPTION TRENCHES TO WATER LINE
ABSORPTION TRENCHES TO IRRIGATION
ABSORPTION TRENCHES TO PROPERTY LINE
BUILDING SEWER TO WATER LINE
Measured November 13, 2013
Page 1 of 1
BCLLC
ACTUAL (MIN. REQ'D)
20 FT
(5 FT)
100 FT
(10 FT)
100 FT
(10 FT)
NA
70 FT
(20 FT)
40 FT
(25 FT)
NA
40 FT
(10 FT)
55 FT
(10 FT)
Nov 11 13 08:11 p Artisan Designs
9707667445 p,1
Copeland Concrete, Inc.
28803 Highway 6
Rifle, CO 81650-9452
970-625-1112
970-625-I 1 l0 fax
Sig
Name [Address
Grand Junction Pipe & Supply
P.O Box 1849
Grand Junction, CO 51502
"PIWS7E�THE
LORD"
Ship To
Gypsum 1204 Dagget Lane
Doug 376-2511
Racking Slip
Date
S.O. No.
10/3 1/20I3
303 3
Customer Phone I P.O. No. I Ship Date I Ship Via f Customer Contact I
970-524-4440 1 10-4008357 1 10/31 /2013
4 rott
weight
Item
Ordered
Description
13560
R-1500 gallon .,.
1500 gallon septic tank
6
R-139000
3
effluent filter
R-Gypsum
Delivery charge to Gypsum
Unkss Copeland Concrete delivers and «s o4r tanks we are
NOT responsible for an 3 teaks
Signature
r. �
BROCK CONSULTING, LLC
Professional Services
Revised September 4, 2013
HAGEN RESIDENCE
1204 Daggett Lane, Gypsum, CO 81637
PN 2111 19100 003,
DESIGN CALCULATIONS FOR ABSORPTION TRENCH SYSTEM
■ REFERENCES ■
BrLLC
P.O. BOX 3644
Eagle, CO 81631
Cell 970-471-2121
Fax 970-328-0875
Individual Sewage Disposal Systems, Colo. Dept. of Health, Amended 9/15/2004
Eagle County Regulations for Individual Sewage Disposal Systems (ISDS)
Infiltrator Chamber Systems Septic Design and Installation, Current Edition
Because of the site conditions and gentle slope, a Chamber Trench System is recommended for
this site.
DESIGN FLOWS
Number of bedrooms = 3, Maximum daily Flow (Qmax) = 1.5 X Ave. daily flow
Qave = 3 bdrms x 2 persons/bdrm x 75 gallons/person/day = 450 gpd
Qmax = 450 X 150% = 675 gpd
SEPTIC TANK
Volume = Qmax/24hrs x 30hrs Detention
V = 1406 gallons (sized for potential future 2 bedrooms in basement)
Use 1,500 Gallon (2 compartment) Valley Precast, Inc. or equivalent. Each compartment 750
gallons.
ABSORPTION AREA
Design percolation rate was calculated to be T = 10 MPI (minutes per inch)
Based on Percolation rate of 10, and Course to Fine Sand (all cobbles to be removed), a Long
Term Acceptance Rate (LTAR) of 1.2 GAL/Day/sf is shown in the table (CDPHE, pg 34) as
acceptable.
A = Qmax/1.2gpd/sf
A = 675/1.2 = 562 sf
As a double check,
Using Eagle County Table 5; Absorption Area = 165 SF/bedroom or 495 SF,
Page 1 of 4
For conservancy, this design to use 675 SF.
INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION
State Reduction for Trenches in Chamber System is 50%
Square Feet per chamber is 10.0 (Quick 4) 30"x48"
Final Absorption Area Required = 562 (0.50) = 281 sf
Number of Chambers = Req'd Area/10.0 sf/chamber = 281/10 = 28 Chambers
Recommend to install two (2) rows of 14 chambers.
* Meets Manufacturer Minimum Recommendations
Given site conditions. Use 2 Rows of 14 Chambers.
Product to be Infiltrator Systems, Inc. "Quick 4" Chambers
INSTALLATION
Install all components to the required setbacks required by regulations. No over excavation
allowed for septic tank. Install septic tank level. Install the delivery pipe from the residence to
the septic tank and septic tank to absorption trench. All pipe to be minimum 2% slope,
Schedule 40 PVC (ASTM D 2665). Insulate under driveway or any parking area with 2" rigid
insulation. Install chambers level. Connect relief pipe from trench to trench per plans. Backfill
and compact the pipe trench, septic tank, and chambers to manufacturer specifications. Cover
inspection lids with maximum 8-inches of soil. All covers shall be child proof (100 lb. Min.).
NOTES:
l . All installations shall meet the rules and regulations of the Eagle County Environmental
Health Division, Chapter 4, Individual Sewage Disposal Systems.
2. The building sewer line from the house to the septic tank shall have a slope of/4 inch
per foot (2%). Bends in the building sewer shall be limited to 45 degrees.
3. The septic tank shall be installed level. The tank shall have removable covers or
manholes to within 8 inches of the finished grade, for inspection and cleaning.
4. Strip all topsoil in absorption bed area. Reuse for vegetative cover.
5. Excavate three (3) feet wide trenches where possible. The horizontal distance from'
sidewall to sidewall between the trenches shall be a minimum of six (6) feet. NA.
6. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing.
7. Assemble and install the Infiltrator Chambers in the trenches according to the
manufacturer's recommendations.
8. Backfill the sidewall area with native on -site (sandy) soil for proper support.
9. Backfill the trenches with a minimum of 12 inches of tamped soil cover.
10. Avoid vehicle traffic over the system.
11. The Septic System Installation shall be inspected by the Design Engineer
Backfill.
I
Page 2 of 4
MINIMUM DIMENSIONS TO FACILITIES
SEPTIC TANK TO BUILDING
SEPTIC TANK TO WATER LINE
SEPTIC TANK TO ABSORPTION TRENCHES
SEPTIC TANK TO WELL
ABSORPTION TRENCHES TO BUILDING
ABSORPTION TRENCHES TO WATER LINE
ABSORPTION TRENCHES TO IRRIGATION
ABSORPTION TRENCHES TO PROPERTY LINE
BUILDING SEWER TO WATER LINE
ACTUAL (MIN. REQ'D)
20 FT
(5 FT)
100 FT
(10 FT)
20 FT
(10 FT)
NA
30 FT
(20 FT)
80 FT
(25 FT)
120 FT
(50 FT)
30 FT
(10 FT)
60 FT
(10 FT)
August 22, 2013 Hagen Septic System Soils evaluation
8 ft. profile hole
� h
n
rr�r l
The above picture taken during percolation testing is indicative of the soil cot
and below the proposed elevation of the absorption field. The soil type is cob
gravelly, silty sand based on H-P Geotech soils report. Approximate analysis
is:
_ V
4 offf G !'
8 f
Page 3 of 4
4-� 13
MINIMUM DIMENSIONS TO FACILITIES
SEPTIC TANK TO BUILDING
SEPTIC TANK TO WATER LINE
SEPTIC TANK TO ABSORPTION TRENCHES
SEPTIC TANK TO WELL
ABSORPTION TRENCHES TO BUILDING
ABSORPTION TRENCHES TO WATER LINE
ABSORPTION TRENCHES TO IRRIGATION
ABSORPTION TRENCHES TO PROPERTY LINE
BUILDING SEWER TO WATER LINE
ACTUAL (MIN. REQ'D)
20 FT
(5 FT)
100 FT
(10 FT)
20 FT
(10 FT)
NA
30 FT
(20 FT)
80 FT
(25 FT)
120 FT
(50 FT)
30 FT
(10 FT)
60 FT
(10 FT)
August 22, 2013 Hagen Septic System Soils evaluation
8 ft. profile hole
The above picture taken during percolation testing is indicative of the soil conditions ,t�ti�ltit,�;�
and below the proposed elevation of the absorption field. The soil P P p type is cobbly- ���i'DO REG/��1f%f.
gravelly, silty sand based on H-P Geotech soils report. Approximate analysis b •'' L .• �,�
is:
Page 3 of 4
5 1 °
'ems;
o
Topsoil
top 1-2 ft
Silty Loam
25%
Fine sand
40%
Fine Gravel
10%
Coarse Gravel
5%
Cobbles
20%
The soils are conducive for a "septic" on -site wastewater treatment system, providing all
cobbles are screened out of the bedding and sidewall area. No cobbles in backfill to
Prevent point loading of infiltrators. This site and design will be evaluated carefully
during excavation for soil conditions, and modified if they change measurably as
necessary.
•,.....,. RFGI
<<<
g �N l ag. e
�0 •MN• �x
Page 4 of 4 oaf, NA E-
�f/{p:.vlett�
I au•lel,Cjn} ueo®6 up ins uooMooaq
C L 8 0— q Z� (O L 6) X v 3 O a V �J O-10 0 `,,1 N n O O 31 O d ------_—_--------_-----
Z l Z— l L V (O L 6) 301330----------- - ----- w
G , 9 G q 0 (3v � 010 o 310 V 3 5- OQ ©Q 1 L � � � � Z ri/ ' -----------:53111 3JN3a3j3a lVNa31X =
:]A1zJQ dS3 W 9L8 iJ 1 �{
01-1 E3e ---- _---
AB SNO5N34 31V0 'ON ------.-
• Z
O
V �
O
O
mow
wl O
LL
O
Z
O
�st
now
i
%LJ�
a tW Ljj
ts. tL
LU
V11
gar
Qz
>�
r�
ra rQ
-sin � -?
L, o N
4 p,rp
1<1
R v
�- All
N o
01
;t�i
'p-- MAAjFl Nods
o
�
A
�
s
T
a Fri F
n
\, 3rTt
TE-
�
m
r �
T
0
z �
© ` 4
PPROVED:� DATE: PI AN
—
C/1 ME BY:
TERNAL REFERENCE FILES:
�m — _ _ — p6.1 till i�► 0.0 Oo�
---- EAGLE COUNTY, COLORADO
LLC
876 MESA DRIVE
EAGLE, COLORADO 81631
OFFICE (970) 471 —21 21
FAX (970) 328-0875
brook con su It in g(Mccen to ryt el.n et