Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout42 Blue Creek Overlook - 239127106006 - OWTS-6-14-10940VOIDDEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.ealec t�.us
-EAGLE COUNTY
P.O. Box 179
500 Broadway
Eagle, CO 81631
www.eaglecounty.us
APPLICATION FOR ON -SITE WASTEWATER TREATMENT SYSTEM OWTS PERMIT
INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00
Fee includes the design review, permitting and maintenance of OWTS records
Make all checks payable to: Eagle County Treasurer
Property Owner: CI - I'�Yl -)- I f f S. —MO. one:
Owner Mailing Address: zz I blu LL- email:
Professional Engineer: �1 C.Lrf r � odjl —[[ ef? p _
Applicant / Contact Person: —Phone:
Licensed Systems Contractor Name / Company: f S Co (
��I
Contractor Mailing Address: Contractor License #: L W-.03
Contractor Phone Number: � g - (� (Z email:;
OWTS Permit Application is for: New Installation ✓Alteration Repair
Tax Parcel Number: a3 91- ,P-] 0 t - D D (o Lot Size:
Assessor's Link: www.eaglecounty.ps/patic/
Physical Address: 14 Z E2 V. Q C,ji
Legal Description: T ZO u k 1` n q v\c V
Building Type: _� Residential / Single Family Number of Bedrooms:`
Residential / Multi Family Number of Bedrooms:
Commercial / Industrial Type of Use:
*As of 06/27/2014, all systems require design by a Registered Professional Engineer
Type of Water Supply: ✓ Private Well Spring Surface Public
If Public, Name of Supplier:
Applicant Signature: ' - --Date:
Office Use Only: OWTS PERMIT #
BUILDING PERMIT #
Amount Paid: Receipt #• Check #• Date:
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaalecounty.us
EfiGLf CC)UNTY
P.O. Box 179
500 Broadway
Eagle, CO 81631
www.eaglecounty.us
OWTS PERMIT # BUILDING PERMIT # '��S — to -' l4f — (O 9 ® Z
INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE 400.00
This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final
Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or
consultation is needed. The re -inspection fee is $135.00
Make all remittance payable to: Eagle County Treasurer,
Property Owner: awo"p % Phone:
Mailing Address: 914 91,LLOR �- email yis4,
Registered Professional Engineer:
Applicant or Contact Person: �en �C.¢. "�ewvt Phone: q ZC) _ � ! 8 "' � �z.�
Tppa Eli RED FOK Ei1aL6 Co
Licensed Systems Contractor: TI M MA'i;.5i+At_ L License # ON VAFC 31. WILL V0
FOR ri&vc/Dd_
Company / DBA: r I"" T�L SXCAVQATIM G AHV phone: Q%®" `?29'S20%
COONOR
Mailing Address: email
�Vj® 30><� 2- :✓76 614;5\^/tT Co 51 b2 1
/��
Permit Application is for: New Installation Alteration Repair
Location of Proposed Onsite Wastewater Treatment System:
Legal Description: ��r 20 Y'IOUNTA. M Mla.�.naw Kr�r'iGd•l, SCGOf'�i� �)L.(I"{(��
ACGOKVIN& 10 ,t' T"av' TAWRMOP 1?�Gcyt�i7zi7 irtJL�UST's 1017 E+oe 29q AXi rA&&�
Tax Parcel Number: 2.311 P2.71 " Oi! W G Lot Size: 8 7 AGK95 2G<o
Assessor's Link: www,eaglecounty.us/patie/
Physical
Address t^JvHZ,
Ltic
K
Building
Type:
Residential /Single Family
Number of
Bedrooms:
Residential /Multi Family Number of Bedrooms:
Commercial /Industrial* Type of Use:
*These systems require design my a Registered Professional Engineer
Type of Water Supply: X Private Well
If Public Name of Sur-"---
Applicant Signature:
:k:k:k:k.:k'k•%k *8�8-** 8�*=k*:k:k:
Spring _Surface _Public
Office Use Only
Amount Paid: Receipt #: Check #: Date:
r..c
r
1404
BUILDCO 23-7/10201007
JACOB DOWN 7z17esaale
Po BOX 9085
ASPEN, CO 81612-9085 ;1 Atc
t9701618-6823
P.O. Box 179
�� 500 Broadway
...� Eagle, CO 81631
www.eaglecounty.us
®coFagankN.�. �G?tom 1 C�
lor
welwlsfargaxwn .de
IYP
,NT SYSTEM
�: L0 20000761:
BE INCLUDED)
-ajvK KhjrA1K FEE 80$0.00 MINOR REPAIR I'EE 400.00
This fee includes the OW'l'S Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final
Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or
consultation is needed. The re -inspection fee is $135.00
Make all remittance payable to: Eagle County Treasurer.
Property Owner: 6 kK—%M f,IJL � 43&jd95 %d&RaH Phone:. _ Gi 70 ` (; f g — 76 C7 5
Mailing Address: 514 .4 xa-g` �� email A 'e'S, • ytp-4-
Registered Professional Engineer: Phone:
Applicant or Contact Person: Joke 12,0W I Phone: (9U - 616 - 613Z3
- VRI 0>q11FO K Eid 19 cc
Licensed Systems Contractor: U I M dA1C:5i-bAL -- License # ON VWG 31. W1LL VO 1C6.T1Fi r
Pole VWri6ArAL.
Company / DBA• 11- T VXGA1rQT1H CG Atit-) Phone: 4170" R1-9 "t`r" - %
t� GR
Mailing Address: _ email
tV- O ��- 2-5 !;4 �1S CO �162.1
Permit Application is for: New Installation X Alteration Repair
Location of Proposed Onsite Wastewater Treatment System:
Legal Description: -L—M- 20 zjgo AJN A -Vow T,4riCA. SCC00P FILI HG,
ACC0j:D1r4G To -r" K T1 -1- 09alolc F-fiR—'m=P0q> At)&VW **/�� 1'17v 2eq Acr rA&
Tax Parcel Number: .�'�1-2.71- 0&- 6QG Lot Size: CO - S 7 ,4Gxo5 ZGIo
Assessor's Link: www.eaglecounty.us/Ipatie/
Physical Address U 4 Z &i�- K. g2v o iC
Building Type: Residential / Single Family Number of Bedrooms:
Residential / Multi Family Number of Bedrooms:
Commercial / Industrial* Type of Use:
*These systems require design my a Registered Professional Engineer
Type of Water Supply: X Private Well Spring Surface Public
If Public Name of Supplier:
Applicant Signature: s' VNI jl r` 1 V
Office Use Only
Amount Paid: Receipt #: Check #: Date: %� /
May 3, 2015 Project No. C1144
Mid Levis
Buildcolorado.mid@gmail.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
42 Blue Creek Overlook
Eagle County, Colorado
Mid,
ALL SERVICE septic, LLC performed a subsurface investigation and completed onsite wastewater
treatment system (OWTS) design for the subject residence. The property is located outside of Basalt, in
an area where OW TSs and wells are necessary.
The legal description of the property is Lot 20, Mountain Meadow Ranch, Second Filing, according to the
plat thereof recorded August 3, 1979 in Book 289 at Page 266 as reception No. 185666, County of Eagle,
State of Colorado.
SITE CONDITIONS
A 3-bedroom, single-family residence presently exists and is utilizing an existing OWTS. A remodel is
proposed and a bedroom will be added. The existing OWTS consists of one 1000-gallon, two-
compartment concrete septic tank and a 700 square foot pipe and gravel soil treatment area (STA).
Eagle County Environmental Health Department Individual Sewage Disposal System (ISDS) Permit
669 documents this system. The percolation rate is documented as 10 minutes per inch (MPI) and
was sized to accommodate a 3-bedroom residence. The system was given final approval by
Eagle County on November 21, 1984. The existing OWTS was inspected by CBO, Inc. on February
26 & 28, 2014 and was found to be functioning normally with no signs of surface saturation or failure
(report enclosed).
The residence is served by a private well, which is located greater than 50-feet from the proposed and
existing septic tank and greater than 100-feet from the existing STA.
SUBSURFACE
The subsurface was investigated on April 28, 2015 by digging two soil profile test pit excavations (Test Pits).
A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
The materials encountered in the Test Pit #1 consisted of dark to medium brown, moist, topsoil to 18-
inches, underlain by tan to white loamy sand (caliche) with angular basalt boulders to a maximum depth
explored to 7.5-feet. No bedrock or groundwater was encountered.
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 2
The materials encountered in Test Pit #2 consisted of dark brown, moist, topsoil to 18-inches, underlain
by tan to white loamy sand (caliche) with angular basalt boulders to a maximum depth explored of 3.5-
feet. There was backhoe refusal in this pit at 3.5-feet on a large boulder. No bedrock or groundwater was
encountered.
A tactile analysis was taken from the soil at approximately 3 to 4-feet below grade. The sample was
sieved and the soil formed a ball but no ribbon. The soil structure shape granular with very fine grains,
had moderate structure grade, and loose consistence.
STA sizing is based on Soil Type 1, Loamy Sand. This is consistent with the Eagle County
Environmental Health Department percolation testing report dated 8/21/84 with an average percolation
rate of 10 MPI and soil type reported as Silt/ Sand / Volcanic Rock.
A long term acceptance rate (LTAR) of 0.8 gallons per square foot will be used to determine
minimum sizing criteria of the STA, in accordance with Table 10-1 Soil Type 1 presented in the
Eagle County On-Site Wastewater Treatment System Regulations, adopted May 13, 2014.
Test Pits observed April 28, 2015
Test Pit #1
Test Pit Backfill Sieved sample
Test Pit #2
Test Pit only dug to 3.5-feet (backhoe refusal)
Page 3
DESIGN SPECIFICATIONS
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 600 GPD will be used.
We are proposing an alternating system to allow continued use of the existing STA2.
Design Calculations:
600 GPD x 48 hour retention time = 1200 gallons minimum septic tank capacity
Existing STA (pipe and gravel)
600 GPD / 0.8 gallons / SF = 750 SF
750 SF x 1.2 (gravity bed) x 1.0 (pipe and gravel) = 900 SF minimum STA
50% of 900 SF = 450 SF
Existing 700 SF > required 450 SF
Proposed additional STA (chamber bed)
600 GPD / 0.8 gallons / SF = 750 SF
750 SF x 1.2 (gravity bed) x 0.7 (chambers) = 630 SF
50% of 630 SF = 315 SF
Minimum 27 ‘Quick 4’ Infiltrator® chambers
The existing septic tank will be properly abandoned in place. The septic tank must pumped and
collapsed and remaining void filled with gravel, sand, or compacted soil. A new minimum 1250-gallon,
two-compartment concrete septic tank will be installed. An effluent filter (or screen) must be installed on
the outlet tee of the septic tank.
A Bull Run valve must be installed on the 4-inch pipe exiting the septic tank, connecting both the existing
and new STAs. This Bull Run valve must be accessible from grade. The valve must be rotated annually,
allowing each STA resting. Rotation of the valve should be documented by the homeowner and records
maintained for future reference.
The existing STA consists of 700 square feet of pipe and gravel infiltrative area. An inspection port is
present at the end of the STA and must remain. This inspection port may be cut to grade and covered
with a valve box for access. If the pipe from the Bull Run valve to the existing STA is found to have an
accumulation of sludge, we recommend jetting this line. We also recommend removal of the existing
garden area above the existing STA.
The new STA will consist of three rows of 9 ‘Quick 4’ Infiltrator® chambers, connected with a level
manifold, for a total of 27 chambers and 324 square feet of infiltrative area. The chambers should be
placed between 2 and 3-feet below native grade. Inspection ports should be placed at the four corners of
the bed and may be cut to grade and covered with a valve box for access.
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
2 Onsite Wastewater Treatment System Regulation #43, Section 43.10 F. 1.
Page 4
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes must be installed to allow pump lines to
drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the
event of excessively high water conditions and shall be connected to a control breaker separate from the
high water alarm breaker and from any other control system circuits. The pump system shall have a
switch so the pump can be manually operated.
Excavation equipment must not drive in excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The contractor should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Page 5
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS
Enclosure: Orenco® Effluent Filter specifications
Bull Run Valve specifications
February 2014 OWTS Inspection Report, CBO. Inc.
Liability Clause: Under no circumstances whatsoever shall the liability of ALL SERVICE septic, LLC, in connection with
any contract, directly or indirectly, exceed the total amount paid by the client to ALL SERVICE septic, LLC for the services
and/or goods which are the subject of the contract in connection with which the liability arises.
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg@gmail.com
February 28, 2014
Sarah Woelfle
Coldwell Banker Mason Morse
sarahw@masonmorse.com
Onsite Wastewater Treatment System (OWTS) Inspection
42 Blue Creek Overlook
Eagle County, Colorado
Sarah,
CBO Inc. performed an Onsite W astewater Treatment System (OWTS) inspection at 42 Blue Creek
Overlook, Carbondale, CO on February 26th and 28th, 2014.
The subject OWTS consists of one 1000-gallon, two-compartment concrete septic tank and a 700
square foot pipe and gravel system. Eagle County Environmental Health Department Individual
Sewage Disposal System (ISDS) Permit 669 documents this system. The percolation rate is
documented as 10 minutes per inch (MPI) and was sized to accommodate a 3-bedroom
residence. The system was given final approval by Eagle County on November 21, 1984.
Access to the septic tank manhole lids were approximately 4 to 6-inches below grade. The septic
tank appeared to be in good condition. Both inlet and outlet tees were present. The septic tank was
pumped in August 2013 by B&R Septic. Water levels in the septic tank appeared normal. Pumping
is not necessary at this time. We recommend installation of an effluent filter on the outlet tee of
the septic tank.
The absorption area appeared to be under a fenced in garden. One observation port was present
on the west end of the observation area and was dry at the time of the inspection. According to
Eagle County documents, the absorption area is pipe and gravel. We do not recommend continuing
a garden above the absorption area. Attached is a fact sheet regarding septic systems from the
University of Nevada Cooperative Extension. Please note the section titled “Can I plant a vegetable
garden over a leach field?”
At the time of the inspection, the residence was vacant and the absorption area was covered with
snow; however, there was no indication of saturation or failure.
Recommendations:
Add effluent filter to outlet tee (see attached specification sheet). We recommend the
Orenco® 4-inch Biotube Jr. This filter should be cleaned annually.
Pump septic tank as needed, as gauged by accumulation of solids.
This evaluation is not a guarantee of future system performance. Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. 2016
Enclosures: Orenco Biotube Effluent Filter Product Sheet
University of Nevada Cooperative Extension Planting on Septic Leach Fields
Google Earth map / Measurements to septic tank lids
Eagle County Documents
February 26, 2014
Looking from deck toward area of system Looking west toward observation port
(southwest)
Observation port at end of pipe and gravel system