HomeMy WebLinkAbout95 Polar Star Ln - 210518201005 - OWTS-6-14-10864Work Classification:Alteration PO BOX 3007 VAIL CO Address Owner Information Permit Status:Active Project Address 210518201005 Permit Type:OWTS Permit Permit NO.OWTS-6-14-10864 Expires: 10/11/2014Issue Date:6/13/2014 Parcel No. 95 POLAR STAR RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: 970-926-6244 Cell: Inspection For Inspections call:(970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)926-9088LKP Engineering, Inc Contractor(s)Phone Primary ContractorLicense Number BRONN EXCAVATING (970)328-6476 Yes16-14 VANGALIS, ANTHONY - PEEPLES, PATRICIA E. VANGALIS, ANTHONY - Permitted Construction / Details: Install a 1,000 gallon concrete two compartment septic tank and effluent line exactly as indicated on the LKP Engineering, LLC design drawing dated June 4, 2014, including the double encasement across the irrigation easement. Contact the design engineer to conduct inspections and certify the installation prior to sending as-built drawings. Final certification must be submitted to Environmental Health and approved prior to using the system. Contact the design engineer for specifications regarding the connection of the effluent line to the existing serial distribution line and assure that lines are properly bedded prior to inspection. The tank is to serve a new garage with bathroom and the effluent line will be connected into the last serial connection line between trenches of the existing soil treatment area installed under ISDS Permit #1716-97. NOTE: Our septic system record from 1997 indicates that the irrigation ditch is abandoned although an easement still exists. If the irrigation ditch is in use, the ditch must be lined to conform with setbacks and to protect the existing system from failing. We have no records of any pumping or maintenance having occurred since 1997. Issued by: Environmental Health Department, Eagle County, CO June 24, 2014 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification:Alteration PO BOX 3007 VAIL CO Address Owner Information Permit Status:Active Project Address 210518201005 Permit Type:OWTS Permit Permit NO.OWTS-6-14-10864 Expires: 10/11/2014Issue Date:6/13/2014 Parcel No. 95 POLAR STAR RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: 970-926-6244 Cell: Inspection For Inspections call:(970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)926-9088LKP Engineering, Inc Contractor(s)Phone Primary ContractorLicense Number BRONN EXCAVATING (970)328-6476 Yes16-14 VANGALIS, ANTHONY - PEEPLES, PATRICIA E. VANGALIS, ANTHONY - Permitted Construction / Details: Install a 1,000 gallon concrete two compartment septic tank and effluent line exactly as indicated on the LKP Engineering, LLC design drawing dated June 4, 2014, including the double encasement across the irrigation easement. Contact the design engineer to conduct inspections and certify the installation prior to sending as-built drawings. Final certification must be submitted to Environmental Health and approved prior to using the system. Contact the design engineer for specifications regarding the connection of the effluent line to the existing serial distribution line and assure that lines are properly bedded prior to inspection. The tank is to serve a new garage with bathroom and the effluent line will be connected into the last serial connection line between trenches of the existing soil treatment area installed under ISDS Permit #1716-97. NOTE: Our septic system record from 1997 indicates that the irrigation ditch is abandoned although an easement still exists. If the irrigation ditch is in use, the ditch must be lined to conform with setbacks and to protect the existing system from failing. We have no records of any pumping or maintenance having occurred since 1997. Office Copy June 24, 2014 Issued by: Environmental Health Department, Eagle County, CO Date Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaalecounly.us EAGLE COUNTY P.O. Box 179 500 Broadway Eagle, CO 81631 www.eaglecounly.us OWTS PERMIT # QW— D BUILDING PERMIT # KES --'5 -Yrf— I U tub INCOMPLETE APPLICATIONS WILL NOT 9E ACCEPTED (SITE PLAN MUST BE INCLUDED) FEE SCHEDULE APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE 400.00 This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $135.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: AX/7"µCWtj 1l✓!`A :� -+-L J S Phone: c1 75 3 `7 b 1 I MailingAddress: f _7>01/i2 SIM P- W-40' email AV !-10A46-T 2 Registered Professional Engineer: i� i Z n I��t� ✓5l Phone: 9 7b % O D Applicant or Contact Person: O 1,L Phone: V 0 326 7_ 1 f Z_ Licensed Systems Contractor: I11 �i nse # rrl Company / DBA: &0-4,n Phone: --7 I�!v � b a -ors n ex ��(o �-S y¢!�am, o- c Mailing Address: �l`Y Goa--�� TT email l-Gc J Permit Application is for: New Installation Alteration Repair Location of Proposed Onsite Wastewater Treatment System:-�'- Legal Description: a Lo L 5— G cZ&W�_S- Tax Parcel Number: Z I D Y/ P, Z 0 100 3__ Lot Size: Assessor's Link: www.eaziecounty.us/patie! Physical Address: 00 9 r/"�O /VA- 64 0 &V L- 4 tt� 5- 0 e T b 37 Building Type: Residential / Single Family Number of Bedrooms: ,0-r Residential / Multi Family Number of Bedrooms: Commercial / Industrial* Type of Use: *These systems require design my a Registered Professional Engineer Type of Water Supply: Private Well If Public Name of Supplier: Applicant Signature: Office Use Only t� Amount Paid:_ Receipt #: Spring Surface __�L Public Check #: Q&�L Date:&//Z-4 September 25, 2014 Anthony Vangalis PO Box 3007 Vail, CO 81658 RE: Final approval of septic permit OWTS-6-14-10864; Tax parcel #210518201005; Property location: 95 Polar Star, Edwards Area Anthony: This letter is to inform you that the above-referenced alteration septic permit has been inspected and finalized. Additional information about the maintenance your septic system needs as well as information about private wells can be accessed through web site links provided on the Environmental Health Department’s home page at http://www.eaglecounty.us/envHealth/ Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap roots, irrigation systems and parking areas above the drain field can cause premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. By following a few simple guidelines, like avoiding grease or other additives down the drain and making sure your septic tank is on a pumping schedule, your system has been designed to last for many years. If you have any questions regarding this information, please contact us at (970) 328-8755 and reference the OWTS septic permit number. Sincerely, Terri Vroman Administrative Technician IV cc: OWTS permit folder Energov electronic file DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us RAYMOND P. MERRY, REHS Director w u z a 0 a z 0 d w m M z lu aw I 1 i • � • w S I •il ALWAYS SAVE YOUR RECEIPTS HOW PAID F�91at �O_ CASH CHECK MONEY ORDER WOD1 . a SL82] Invoice Invoice Date:8/22/2014 Invoice #:14-2934osi Bill To: AV Homes, LLC Tony Vangalis P.O. Box 1758 Edwards, CO 81632 Project Address: Lot 4, Block 5, Lake Creek Meadows 95 Polar Star Road Eagle County, Colorado LKP Engineering, Inc. P.O. Box 2837 Edwards, CO 81632 Terms:Due upon Receipt PROJECT NO.:14-293... Phone # 970-926-9088 E-Mail luiza@lkpeng.com Web Site: www.lkpengineering.com Total Balance Due Payments/Credits Accounts not paid within 30 days of the date of the invoice are subject to a 2% monthly finance charge Description Hours/Qty Rate Amount Inspection of Septic System Installation and report 370.00 370.00 As-Built Sketch 185.00 185.00 Pay online at: https://ipn.intuit.com/z7r7s9h4 $555.00 $555.00 $0.00 August 21, 2014 Mr. Tony Van Galis AV Homes LLC P.O. Box 1758 Edwards, CO 81632 E-mail: avhomes@comcast.net RE: Inspection of Septic System Installation New Garage/Office Lot 4, Block 5, Lake Creek Meadows 95 Polar Star Road Eagle County, Colorado Project No. : 14-2934 OWTS-6-14-10864 Dear Tony: At your request, on August 15 and 19, 2014, we visited the construction site for the New Garage/Office, on Lot 4, Block 5, Lake Creek Meadows, 95 Polar Star Road, Eagle County, Colorado. The purpose of our site visits was to inspect the installation of the addition to the existing septic system. They installed the system in overall compliance with the septic system design, Drawing No. 14-2934SD.DWG, dated June 4, 2014. They constructed a new, 1000-gallon, two compartments, a concrete, septic tank, as shown on the attached as-built sketch. They also constructed an effluent line from the new septic tank to the existing leachfield. The new effluent line was connected to the serial distribution pipe connecting the last two trenches on the north end of the leachfield. There was a cleanout between the septic tank and the new garage/office, and an additional two cleanouts. One of the additional cleanouts was right after the septic tank, and the other one about 100 feet after the first cleanout, along the effluent line, between the tank and the leachfield. The T’s in both compartments of the new septic tank were at least 14-inches long. There is no other warranty either expressed or implied. If you have any questions, please do not hesitate to call. Sincerely, LKP Engineering, Inc. Luiza Petrovska, PE Enclosure cc: Eagle County Environmental Health Department, E-mail: Terri.Vroman@eaglecounty.us, environment@eaglecounty.us \\SERVER\Shared\_WP X4-LKP\_2014\14-2934OSI-add.wpd P.O. Box 2837, Edwards, CO 81632 Tel (970) 926-9088 i N 00 0 0 a _ zz- co�Z = ,o cn�0 > \ 2� c9 .o o, 0 \\\\SO 66—\\ \ o F-�oz \\� \ \ S o� mOr�0 -- N \ m n O z m \ °W\ o m c — \ m_ --- tnmrx DC �- mZ\' \ \ \ m ° �\ \n \\ ` TZn2FT00D\\ \ Ozr�mm o r 0 gym oN m CzD rT < $$ $c. _ — —---48-- — O ^' D m D No Z m — — — — — mmo D�� \ �\ \ \ gb-- m� CD \ 0 \� \ C Z m m 2 mu O }} lo coc»��D �;u II II II II O r N o II . 0 0 N O &J �� Cw C'4 O J 0 m OJDr7-0 D n ' z cn cn rm c/) < m O� O J D 0 Fll F- m C C r r- �: Z M F71 O D <_ D � O � 60 O O O :c5l Om < C rTl � z O 0 A a� o 'Z \ �o <r __— w \ rl 0_0� \ \\ N mm —\ � elm — -- \ m :*F71 cn \ \ r czm\ �I\ \ y�000jD D Dcn OTW\\ Omz(v — -- r z\,�D \ \�\ \J\ \ \ \ \ m co m \ma % 0Jz \` C m :�/ o m \ � A r Z<D�OJ �c7 D m \ �� v\ \ ymZcn /rZ zmD �D Ao �— \ Dm Kcn �z cn-n \ �\ �z� m� cmm -0-- m mmnrTl K�2 Z� _-n mm \ Omm m �� /+ \ \ �zn Zz 1/SOT < mz, ,07 s\ VJ 0 /rn Sm o�c»F—;�UD � II II II II N (-D II zcl�0cn0 C'DCl /o 4�: cry 0 0 cl. 0 0-) 0 d co 0 O m r D z n O z C7 m m O m p C D r m z n0 �J J r r O Z ^ l J O ^z J m gy^ VJ Tm V J TZ V (n ( D O r r p r cn r 0 X r m m C O - W m O A � D m 7o D � m D m c � 0 m r 0 r r � CO � m 2 cn = m cn i O m r) p p >D _ _ m F O n 0 Z_ > � cn cn 2 i O i 0 o m C 2 n D r _ r > O o 0 0 0 m z O m ---OZL---�—\ /---18---- \ / O0o n�0 —� �z m�� �m /m�0 _----16---- Zm8D \ — -- cnmZ O�oz\� mcn� i m�D n\\m / \-- \� p co m — � D -2Tz r-- — O o m n Z n m D � r n z 7 O U) cn r 2 m= 0 r Cr z- z� cn ' me Oi I I —I I I I I I \I I I I I I c„i CO _ c) z A W N O )zmDr-Oma:M m )> � m z �<rz00co �Omcn in<mcn 9Cc)� Dm— � O D 0 W C r c� j m� D— n m q*-< Z00 q>mZ-0<zc )m<cn0;a 0 � �Z� cnr- 0�r-> 07m �cnm�zDm� n D z m o z z m ncnD�m0�� r )�lnmr2zU)rD �m >�Z--i 00 W �mm 0 m < r <> =m� Ln z z � ' 00 W=m Z� zm� n c)0 nD0 D r c) i m� 0U) m — m 2 o ?czn =r-m m2m Om m D Z m 2 m 2 m 0 0<cn z0� p ii m mc2 -0 -0 :*mm m 0 -j ron 0070 � O cDz 0m0 C) � � Fn 0z0 �o �c/) mzz0 �� m00 m* -n— OO C7oZ m0 Z ZX Z CD �m0 DX 0 r � r D m m � O z r zz cnmc) 0 D (n cn m m m m 0 m cDn iDD 0 71 o7> ? m�0 X m mm� m Z D = 0 m 00D m rmz >�O 2mm z m m T r � 07 P m 0 m 0 z c) D r n C r D 0 Z m > o m > CIVIL/GEOTECHNICAL SEPTIC SYSTEM DESIGN - GARAGE ADDITION Z z c> Z m W Qu LOT 4, BLOCK 5, LAKE CREEK MEADOWS O O 75 95 POLAR STAR ROAD N m r r LKP Engineering, In c. EAGLE COUNTY, COLORADO (0N 0 o (0PREPARED � FOR: P.O. Box 2837 Edwards, CO 81632 tel cn (970) 926-9088 TONY VANGALIS WWW.LKPENGINEERING.COM NO. DATE DESCRIPTION BY LKP' Engineering, Inc. CIVIL/GEOTECHNICAL LOT 4, BLOCK 5, LAKE CREEK MEADOWS AS —BOIL T 95 POLAR STAR SKETCH EAGLE COUNTY, COLORADO VAN GALIS GARAGE ADDITION I I I II I I I I I� I I I I I I I to I I I D. lift S .�MM I II I y h y .. .2y.0 • / J / TB o_ yA' g. 2k p• 20.0 EXISTING / / J�'SEPTIC TANK / APPROXIMATE LOCTION OF THE EXISTING LEACHFIELD (THE THREE INSPECTION PORTS WERE OBSERVED / / •Y i\ n AND LOCATED WITH A TAPE DURING THE SITE VISIT ON ARE UNENOT SURVEYED) BUT THEY ARE NOT SURVEYED)17 � V / z 6, 1-11 15� 1000-GALLONS, TWO COMPARTMENTS, CONCRETE, SEPTIC TA 1 l� l I// /NEW 41 C DIAMETERI �SDR35, EFFLUENT LINE L 0 0 / z G ' T E IRRI TION EASEMENT -ACATED Y HTBEEN 1 Q R=16 1 L=174. 1 T=96.6 C LEN= 10' BRG=S( .0 CONNECTION OF THE NE EFFLUENT UNE TO THE LAST TRENCH WITH INFILTRATORS / 0.0' 14-2934 OWTS-6-14-10864 A 7E° AUG 15&19, 2014 0=31'31 R=240. L=132.`. T=68.0. C LEN= BRG=S7 R= C LEN P.O. Box 2837, Edwards, CO 81632, (970) 926-9088, www.lkpengineering.com c >; -- ;: