Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout200 Timber Spring Dr - 194136100010Work Classification: NewPermit
PO BOX 149
EDWARDS CO 81632-
Address Owner Information
Permit Status: Active
Project Address
194136100010
Permit Type: OWTS Permit
Permit NO. OWTS-6-12-7680
Expires: 11/3/2012 Issue Date: 7/6/2012
Parcel No.
000200 TIMBER SPRING DR EDWARDS AREA, CO
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)926-1175
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)926-9088LKP Engineering, Inc
Contractor(s)Phone Primary ContractorLicense Number
DIAMOND A EXCAVATING (970)926-2596 Yes44-12
GERALD & MARY LOU FIALA
Permitted Construction / Details:
Install exactly as depicted on the LKP design drawing stamped and dated June 25, 2012. System consists
of a 1,250 gallon Front Range Pre-cast concrete electric lift station and 380 square feet of soil treatment
area credit via 19 Infiltrator Q4 chambers in two shallow trenches with the top trench receiving a pressure
dose from the lift station and the second trench serially connected to the first. System will serve a
barn/one bedroom caretaker unit. Contact the design engineer for appropriate inspections during
installation. Engineer certification of proper installation is required along with as-built drawings prior to
occupancy of the dwelling or use of the system.
Issued by: Environmental Health Department, Eagle County, CO
August 17, 2012
Date
Customer Copy
Ray Merry
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification: NewPermit
PO BOX 149
EDWARDS CO 81632-
Address Owner Information
Permit Status: Active
Project Address
194136100010
Permit Type: OWTS Permit
Permit NO. OWTS-6-12-7680
Expires: 11/3/2012 Issue Date: 7/6/2012
Parcel No.
000200 TIMBER SPRING DR EDWARDS AREA, CO
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)926-1175
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)926-9088LKP Engineering, Inc
Contractor(s)Phone Primary ContractorLicense Number
DIAMOND A EXCAVATING (970)926-2596 Yes44-12
GERALD & MARY LOU FIALA
Permitted Construction / Details:
Install exactly as depicted on the LKP design drawing stamped and dated June 25, 2012. System consists
of a 1,250 gallon Front Range Pre-cast concrete electric lift station and 380 square feet of soil treatment
area credit via 19 Infiltrator Q4 chambers in two shallow trenches with the top trench receiving a pressure
dose from the lift station and the second trench serially connected to the first. System will serve a
barn/one bedroom caretaker unit. Contact the design engineer for appropriate inspections during
installation. Engineer certification of proper installation is required along with as-built drawings prior to
occupancy of the dwelling or use of the system.
Office Copy
August 17, 2012
Issued by: Environmental Health Department, Eagle County, CO Date
Ray Merry
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
DEPARTMENT OF
}
P.O. Box 179
ENVIRONMENTAL HEALTH
500 Broadway
(970) 328-8755
Eagle, CO 81631
FAX: (970) 328-8788
www.eaglecounty.us
TOLL FREE: 800-225-6136
www.eaglecounty.us
EAGLE COUNTY
OWTS PERMIT # f aTtS -to -1 a -7&Ka BUILDING PERMIT #
INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE $400.00
This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final
Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or
consultation is needed. The re -inspection fee is 1$ 35.00
Make all remittance payable to: Eagle County Treasurer.
Property Owner:J✓YQ 01 4 Q_ �Ov P1 00. Phone: ��'7b9 -- 1 S
Mailing Address: Pb (�CK 14fl, avj Co boSimail aiA.tuUC hu Cx, .0
Registered Professional Engineer: r� hone: q27
Applicant or Contact Person: U lP U v,&yb+f.,-\
Licensed Systems Contractor:
Phone:
Company / DBA: Ry-Cxc�va.
Mailing Address:
Phone: 691D)3- -O?
License #
email
Permit Application is for: 'New Installation Alteration Repair
Location of Proposed Onsite Wastewater Treatment System: cc��
Legal Description: 00 Tt v -7 Ca
Tax Parcel Number: 1CK i - 36 t -O0 -C) t4 Lot Size:
Assessor's Link: www.eaglecounty.us/patie/
Physical Address: U M y Cp tir S V C tQp— I 1EC1WC1-YcS o g Ito
Building Type: Residential / Single Fami y Number of Bedrooms:
Residential / Multi Family Number of Bedrooms:
Commercial / Industrial* Type of Use:
*These systems require design my a Registered Professional Engineer
Type of Water Supply: ✓ Private Well Spring Surface Public
If Public Name of Supplier:
Applicant Signature:
Office Use Only
Amount Paid: Receipt #: Check #: Date:
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Client:Mr. Ulf Lindroth
Ulf & Associates, LLC
P.O. Box 509
Edwards, CO 81632
Location:Lot 7, Timber Springs
200 Timber Springs Drive
Eagle County, Colorado
Project No. : 12029
P-1 P-2 P-3
TIME/DEPTH 22" 22-6/16" 21-14/16"
8:20 am 3-10/16" - 3-2/16" - 3-6/16" -
8:30 am 6-8/16" 2-12/16" 7-8/16" 4-6/16" 8-10/16" 5-4/16"
8:40 am 8-12/16" 2-4/16" 9-6/16" 1-14/16" 11-6/16" 2-12/16"
8:50 am 10-4/16" 1-8/16" 10-12/16" 1-6/16" 13-2/16" 1-12/16"
9:00 am 11-12/16" 1-8/16" 11-12/16" 1" 14-6/16" 1-4/16"
9:10 am 13" 1-4/16" 12-12/16" 1" 15-8/16" 1-2/16"
9:20 am 14" 1" 13-4/16" 8/16" 16-4/16" 12/16"
9:30 am 14-12/16" 12/16" 13-12/16" 8/16" 17" 12/16"
9:40 am 15-8/16" 12/16" 14-4/16" 8/16" 17-12/16" 12/16"
9:50 am 16-4/16" 12/16" 14-12/16" 8/16" 18-8/16" 12/16"
PERC RATE 13 MIN/INCH 20 MIN/INCH 13 MIN/INCH
AVG PERC 16 MPI
Average Percolation Hole Diameter: 8"
Holes Dug and Presoaked : June 20, 2012
Test Run : June 21, 2012
Profile Hole: 0 - 3' - Topsoil
3' - 8' - Light brown, silty sand with
scattered gravels
No Ground water encountered
By: Peter Petrovski
1
DIAMOND A EXCAVATING, LLC
P.O. Box 1957
Edwards, Colorado 81632
Tele: (970) 926.2596
Fax: (970) 926.2597
February 15, 2013
Luiza Petrovska
LPK Engineering, Inc.
P.O. Box 2837
Edwards, CO 81632
Luiza,
We successfully tested the septic pump and alarm system for the caretakers unit at the
Fiala Residence yesterday, the 14th of February. The pump was installed 15” above the
tank floor, and the pump will begin pumping when the water level hits 37”. After
unplugging the pump the alarm system goes off when the water level reaches 44”. Both
work per design. The system will pump 145 gallons per dose.
Les Arney
February 20, 2013
Mary Lou and Gerald Fiala
c/o Ulf Lindroth
Ulf & Associates LLC
P.O. Box 509
Edwards, CO 81632
E-mail: ulf@ulfbuilt.com
RE: Inspection of Septic System Installation
Lot 7, Timber Springs
200 Timber Springs
Eagle County, Colorado
Project No. : 12029- OWTS-6-12-7680
Dear Ulf:
At the request from David, on August 1, September 19, and twice on September 20, 2012, we
visited the construction site at the Lot 7,Timber Springs, 200 Timber Springs, Eagle County, Colorado.
The purpose of our site visits was to inspect the installation of the septic system.
They installed the system in overall compliance with the septic system design, Drawing
No.12029SD.DWG, dated June 25, 2012, and as shown on the attached as-built sketch. The installed
system is for a one bedroom caretaker unit. They installed a 1250-gallon, three compartments, electric
lift, Front Range Precast concrete, septic tank. In the last compartment of the septic tank, they installed a
Gould WE Series Model 3885 Pump, WE0511HH, ½ HP, single phase, 115 volts, 3500RPM. Two
cleanouts were installed between the building and the septic tank, as shown on the sketch. The effluent
line from the pump tank to the first infiltrator of the top trench was a total distance of about 100 feet. The
effluent line was 2-inch diameter sch40 pvc. The pump dosing, the floats function and the alarms were
tested on February 14, 2013, by Les Arney, Diamond A Excavating, Inc. His report is attached. . The
alarm was installed in the barn on the east wall, near the southeast corner.
Nineteen, Standard Infiltrator Chambers were installed in two trenches, as shown on the attached
sketch. The west (upper) trench had eleven infiltrators and it had a perforated pipe suspended from the
top of the first five chambers. The lower trench had 8 infiltrators. The infiltrators were connected with
serial distribution. In the first and last infiltrator of each trench, inspection ports were installed.
Horizontal distance from center to center of the trenches, was 14 feet or more. The depth of the trenches
was no more than 36 inches.
There is no other warranty either expressed or implied.
If you have any questions, please do not hesitate to call.
Sincerely,
LKP Engineering, Inc.
Luiza Petrovska, PE
Enclosure
cc: Eagle County Environmental Health Department, E-mail: Terri.Vroman@eaglecounty.us
J:\_WP X4-LKP\2012\12029OSIQ4-pump.wpd
P.O. Box 2837, Edwards, CO 81632 Tel (970) 926-9088