HomeMy WebLinkAbout425 County Rd - 210505119004 - OWTS-6-12-7627Work Classification: NewPermit CO 871 PO BOX EDWARDS CO 81632- Address Owner Information Permit Status: Active Project Address 210505119004 Permit Type: OWTS Permit Permit NO. OWTS-6-12-7627 Expires: 10/25/2012 Issue Date: 6/27/2012 Parcel No. 000425 COUNTY RD EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-5656 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes35-12 MICHAEL EATON Permitted Construction / Details: Install as depicted on the engineer design as revised and stamped June 26, 2012. System consists of a 1,250 gallon concrete septic tank and 750 square feet of absorption area credit via 37 Infiltrator Q4 chambers installed in 3 serially connected shallow trenches. Protect the sewer line under the driveway from frost and damage due to traffic. System is designed for 4 bedrooms. Engineer certification of the installation is required prior to occupancy of the dwelling or use of the system. Issued by: Environmental Health Department, Eagle County, CO August 22, 2012 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: NewPermit CO 871 PO BOX EDWARDS CO 81632- Address Owner Information Permit Status: Active Project Address 210505119004 Permit Type: OWTS Permit Permit NO. OWTS-6-12-7627 Expires: 10/25/2012 Issue Date: 6/27/2012 Parcel No. 000425 COUNTY RD EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-5656 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes35-12 MICHAEL EATON Permitted Construction / Details: Install as depicted on the engineer design as revised and stamped June 26, 2012. System consists of a 1,250 gallon concrete septic tank and 750 square feet of absorption area credit via 37 Infiltrator Q4 chambers installed in 3 serially connected shallow trenches. Protect the sewer line under the driveway from frost and damage due to traffic. System is designed for 4 bedrooms. Engineer certification of the installation is required prior to occupancy of the dwelling or use of the system. Office Copy August 22, 2012 Issued by: Environmental Health Department, Eagle County, CO Date Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: NewPermit CO 871 PO BOX EDWARDS CO 81632- Address Owner Information Permit Status: Active Project Address 210505119004 Permit Type: OWTS Permit Permit NO. OWTS-6-12-7627 Expires: 10/25/2012 Issue Date: 6/27/2012 Parcel No. 000227 COUNTY RD EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-5656 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes35-12 MICHAEL EATON Permitted Construction / Details: Install as depicted on the engineer design as revised and stamped June 26, 2012. System consists of a 1,250 gallon concrete septic tank and 750 square feet of absorption area credit via 37 Infiltrator Q4 chambers installed in 3 serially connected shallow trenches. Protect the sewer line under the driveway from frost and damage due to traffic. System is designed for 4 bedrooms. Engineer certification of the installation is required prior to occupancy of the dwelling or use of the system. Issued by: Environmental Health Department, Eagle County, CO July 31, 2012 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: NewPermit CO 871 PO BOX EDWARDS CO 81632- Address Owner Information Permit Status: Active Project Address 210505119004 Permit Type: OWTS Permit Permit NO. OWTS-6-12-7627 Expires: 10/25/2012 Issue Date: 6/27/2012 Parcel No. 000227 COUNTY RD EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-5656 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes35-12 MICHAEL EATON Permitted Construction / Details: Install as depicted on the engineer design as revised and stamped June 26, 2012. System consists of a 1,250 gallon concrete septic tank and 750 square feet of absorption area credit via 37 Infiltrator Q4 chambers installed in 3 serially connected shallow trenches. Protect the sewer line under the driveway from frost and damage due to traffic. System is designed for 4 bedrooms. Engineer certification of the installation is required prior to occupancy of the dwelling or use of the system. Office Copy July 31, 2012 Issued by: Environmental Health Department, Eagle County, CO Date Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecountv.us EAGLE COUNTY P.O. Box 179 500 Broadway Eagle, CO 81631 www.eaglecounty.us OWTS PERMIT # D S- —1 a — a!&c;72 BUILDING PERMIT # INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEESCHEDULE APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE $400.00 This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $135.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: PI&,e ! Phone: 0 — /7L -f6 5'6 Mailing Address: 0. U ox $ V Edmaew hem it ar'�7 o,p- �J a� �' Aje+ Registered Professional Engineer: I,. P,, Phone: !4 � f 4 Applicant or Contact Person: uav-� Phone: Licensed Systems Contractor: License # Company / DBA: 6 tqk i�E"J7" Phone: Mailing Address: email 6"JI 1 144 P C tjl n W,W4, it Permit Application is for: Q<New Installation Alteration Repair Location of Proposed Onsite Wastewater Treatment System: Legal Description: Tax Parcel Number: 4�t j� 5 �% �< < �� Lot Size: 44 Cam' _ Assessor's Link: www.eagIecoun!y.us/Patje1 Physical Address: V !?- l C.(} Building Type: Q�._ Residential / Singfe Family Number of Bedrooms: Residential / Multi Fancily Number of Bedrooms: Commercial / Industrial* Type of Use: *These systems require design my a Registered Professional Engineer / Type of Water Supply: l xrivate Well Spring Surface Public If Public Name of Supplier: Applicant Signature: > Office Use Only 01D Amount Paid: VOO — Receipt #: Check #: 10;29 Date: _ BROCK CONSULTING, LLC Professional Services June 19, 2012 EATON RANCH, EDWARDS, COLORADO 425 County Road, Edwards, CO 81632 PN 2105 05119004. Parcel B DESIGN CALCULATIONS FOR ABSORPTION TRENCH SYSTEM a REFERENCES s PLC P.O. BOX 3644 Eagle, CO 81631 Cell 970-471-2121 Fax 970-328-0875 Individual Sewage Disposal Systems, Colo. Dept. of Health, Amended 9/15/2004 Eagle County Regulations for Individual Sewage Disposal Systems (ISDS) Infiltrator Chamber Systems Septic Design and Installation, Current Edition Because of the site conditions and gentle slope, a Chamber Trench System is recommended for this site. Please note that the proposed building plans are for a 2 bedroom single family residence. This design is over -sized for future expansion and permitting without compromising the site! DESIGN FLOWS Number of bedrooms = 4, Maximum daily Flow (Qmax) — 1.5 X Ave. daily flow Qave = 4 bdrms x 2 persons/bdrm x 75 gallons/person/day = 600 gpd Qmax = 600 X 150° o — 900 gpd SEPTIC TANK Volume = Qmax/24hrs x 30hrs Detention V = 1,125 gallons Use 1,250 Gallon (2 compartment) Copeland Concrete, Inc. or equivalent. First compartment 625 gal, second compartment 625 gallons. ABSORPTION AREA _ Sa►41 Warr ? aef-ft o�jS4rvie as Design percolation rate was calculated to be T = 10 MPI (minutes per inch) 5 rm �c z,t 51 � ✓� Q "e' 1 ys & Based on Percolation rate of 10, and Course to Fine Sand, a Long Term Acceptance Ra`e1t�y�t��F,l, (LTAR) of 1.2 GAL/Day/sf is shown in the table (CDPHE. pg 34) as acceptable. �����P�p RE/STf•�,,�. A - Qmax/1.2gpd/sf o�.••'�"$''•. F� A — 900 '1.2 = 750 sf �`� P.O, Box 3644, Lagle, Colorado 81631 Phone (970) 328-0876 Fax,. (910) 328-0875 ED 2007 BrockConsulting@centuryte[.net As a double check, Using Eagle County Table 5; Absorption Area = 165 SF/bedroom or 660 SF, For conservancy, this design to use 750 SF. INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION State Reduction for Trenches in Chamber System is 50% Square Feet per chamber is 10.0 (Quick 4) 30"x48" Final Absorption Area Required = 750 (0.50) = 375 sf Number of Chambers - Req'd Area/10.0 sf/chamber = 375/10 = 37 Chambers* * Meets Manufacturer Minimum Recommendations Given site conditions, Use 3 Rows, with one row of approx. 15, one row of 12 and final row of 10 Chambers each. Product to be Infiltrator Systems, Inc. "Quick 4" Chambers INSTALLATION Install all components to the required setbacks required by regulations. No over excavation allowed for septic tank. Install septic tank level. Install the delivery pipe from the residence to the septic tank and septic tank to absorption trench. All pipe to be minimum 20,b slope, Schedule 40 PVC (ASTM D 2665). Install chambers level. Connect relief pipe from trench to trench per plans. Backfill and compact the pipe trench, septic tank, and chambers to manufacturer specifications. Cover inspection lids with ts4n4umu.8-inches of soil. All covers shall be child proof (100 lb. Min.). NOTES: 1. All installations shall meet the rules and regulations of the Eagle County Enviro> rental Health Division, Chapter 4, Individual Sewage Disposal Systems. 2. The building sewer line from the house to the septic tank shall have a maximum slope of %4 inch per foot. Bends in the building sewer shall be limited to 45 degrees. 3. The septic tank shall be installed level. The tank shall have removable covers or manholes to within 8 inches of the finished grade, for inspection and cleaning. 2 /Strip all topsoil in absorption bed area. 5. Install sandy native Limestone soil in absorption area to maintain minimum 4 feet separation to highest bedrock outcropping. 6. Fxcavate three (3) feet wide trenches where possible. The horizontal distance from sidewall to sidewall between the trenches shall be a minimum of six (6) feet. 7. The bottom and the sidewalls of the trenches shall be raked to eliminate smearin 8. Assemble and install the Infiltrator Chambers in the trenches accordingto �� r manufacturer's recommendations.•t ••�'•�`r�F�''% 9. Backfill the sidewall area with native on -site (sandy) soil for proper sup. 10. Backfill the trenches with a minimum of 12 inches of tamped soil cove& Q5'! 11. Avoid vehicle traffic over the system. , 11.0 Box 3644, La*, Colorado 81631 Phone (970) 328-0876 fax: (970) 328-0875 �O�F•��� •w •w` , 2007 BrockConsulting@centurytel.net 12. The Septic System Installation shall be inspected by the Design Engineer prior to backfill. MINIMUM DIMENSIONS TO FACILITIES ACTUAL (MIN. REQUIRED) SEPTIC TANK TO BUILDING N'h� b ? 100 FT (5 FT) SEPTIC TANK TO WATER LINE 100 FT (10 FT) SEPTIC TANK TO ABSORPTION TRENCHES 15 FT (10 FT) SEPTIC TANK TO WELL 220 FT (50 FT) ABSORPTION TRENCHES TO BUILDING 115 FT (20 FT) ABSORPTION TRENCHLS TO WATER LINE 115 FT (25 Fl-) ABSORPTION TRENCHES TO IRRIGATION DITCH 75 FT (50 FT) ABSORPTION TRENCHES TO WELL 240 FT (100 FT) BUILDING SEWER TO WATER LINE 50 FT (10 FT) P.O. Box 364}, Eagle, Colorado 81631 Phone (970) 328-0876 Fax: (970) 328-0875 �- 2007 BrockConsulting c centurytel.net 1250 Gal. Two Compartment Septic Tank • Monolithic tank meets ASTM-C-1227 Spec. for water and waste- water structures. PLAN • Butyl rubber seal- ant meets Fed. Spec. SS-S-210A. (Provided with tank) • All plumbing shown in lnle diagram is 4" SQR 35. (Provided with tank) Concrete or heavy duty t polyethylene riser system SE{ - Note: N. T. S. 4' Push Seal Gasket typical Ft m s" 120' 51.1011 I 52" __' - Part # Capacities (gallons) A B Approximate Weights Tank Lid Baffle Wall Total PCA-000-254 835 555 8,430 Ibs 3,370 !bs 910 Ibs 12,110 fbs Watertight Front Range Precast Concrete, Inc. 5439 N. Foothills Highway, Boulder, Colorado 80302 '- Phone (303) 442-3207 • (800) 783-3207 • Fax (303) 442-3209 www.flxx.com r+r0111r,1M14 0 RE'Gjs . 90t._ ssP N �Z -8- 0 v N m N o O RO W W Qln NQQ� { W Q N ronx.' O u S > P DO _N m On y K O c z 0 m O O v m 0 a z D O m m N a r 2 C m m a C m 0 0 m X z 0 O n r m Z r C_ XD Zm0 C cn M r- U) D N m r�C/) w � Z 0 n rCl`r�f�E�� h: "O • 3�5 f INFILTRATOR SYSTEMS, INC: PLACEMENT OF FILL MATERIAL WITHIN ZONE OF TREATMENT MOUND FOR PROPER DRAINAGE ESTABLISH VEGETATIVE COVER r r • "� ..�. TOPSOIL, t• y` �., r ��� • • NATIVE BACKFILL - ? /�� ' • INFILTRATOR SYSTEMS I M CHAMBER 6"-11" LEVEL OF INFILTRATI 22"-34" 24"-36" 0, f ZONE OF TREATMENT 9' M NIMUM 18" MAXIMUM COVER 12"-16" SUITABLE SOIL ' / LIMITING ZONE / 4' — / ff/ f ,ff - '•<.z f f f f // fff /f 1 -D ZONE OF DISPOSAL PERMEABLE SOIL OR 4' MIN. FRACTURED ROCK SUBSTRATA Infiltrator PLACEMENT OF FILL S S#ems InC. MATERIAL WITHIN THE Y ZONE OF TREATMENT Scale NOT TO SCALE Checked DFH Date 11118/2004 ACAD NO. N4-He T-X FZT.Dwc Drawn By: BCP Sheet 1 Of 1 T z n a Cmi m bim 000 b Z a 0cm ;0noy mc� O 'C3 •..3 ..'*N s. 2 .1 W ..;A O^ Gm•*z.' �� ;Dmm �,(nm O D A n a � i 3 �pa V /)m cvZ0 m-0oDyCO m 1 z p cn C o m zo T Z �m� o a D�� �0= yZ> m c 1yn=mmC. .. ~3a DA ; o000 ono g� z m A N m oxm mm ❑ s m 0o n A D i o Z O ui W Z y yaFbNO r D O O ca 0 Qn 0 0 N�"Ay O �o 3 NV w o m n o n .; =r D m N T p m y rn D C \�\\��IiSI, 91'f 1JYr/� �r �\ pp nRE CD m cm ox W o n D ai z � O e _a e • �pC)•�t6 ° O O Z y iT3 DvZ<' m n o v o vnio rn X i Ca a�v�C' '� i Q O R D �my0 O �_ _ • 30 • Z. _ � Z � -4Ti >ib '� {m o r • p • M 0 o � i N � m . z m m C) Z Y O D m m r Z m 00 -n m m m F: 0° X z> C) -0o Orm0-D-j n �6 --10;a7 K 0m ��J — fix mm ODr=fn V) 0 > r-m��rn CD z i-n mOXmK m m d (j) c m m z Z Z vCD m 0 0 = co m r C Z � z � �j C O W �N G Z D D y n ? Z -I OC m Q Q o z o �' p aT z m O TX=5 cA � 00 z omanW" Dr C w � �, `Zoo-,o 5 0 m -t pcnivpp>j Ci w 0 AVnD Vl N V n O' Z] m N T SN m o D-a~a V= D ai 00 0, M n c o n to O p m D z ro m D r `` IIIlSSS'ifllJy;� CD o� RE x yr 0o° 0 Q 0 m • i, -f Z -o -4I •NAL £7 c C7 o � N � D O m O O Z z p y MiYIPAMMIuI.. �IIAn�1YT...n In,mwuul lulp�ll�l�l ^ n l ' -4 � a �:Ylaee.Ir. �p:YIK,Y.xr+ n O y c � r NY�,Iw..r IanYsm..w T 0 z � I�a1dInIIN%II n w ^1 � cn � 0 7pIAlYgin: p CO nnmgRllpll1 mMInlHll'ryl m O O ('� m T j 11 Minim x , IlmenAnllm��' Imu-N I114411 � 0 _ D z p IWi+lumilll YuIeI,Y... m ca Z nn oxx.1.` InlYlltllll�l m n n rn�lwlidgll v o o �} unIrlYM.r. IIp�Yxe,nxrm o � -i a a fl n Q Q :E (D (p O P z W z Z Tv0 00y C -K--oZ� O O DWa'A0NQ C.J O N N a cM ra 0 0 ?a X D O O N 7 C y �V V?_A, p1p..;� O M. O CII ol r N z n rn 0 An � D � �tt11�S�:�rtrf►r,►,��r ,N 27 rn 00 t� s-y ouIZI _ O 0 NM � y � r 3 51 �* r7 �= morn ➢ ➢ • r •N' �'.,!ONA 6/26/12 Eagle County Government Mail - Eaton OWTS 6-12-7627 0425 County Road, Edwards I �..+�.GCXJSe Terri Vroman <terri.vroman@eaglecounty.us> EAGLE COUWYM9 Eaton OWTS 6-12-7627 0425 County Road, Edwards Ray Merry <ray.merry@eaglecounty.us> Tue, Jun 26, 2012 at 8:34 AM To: brockconsulting@centurytel.net Cc: #environment <environment@eaglecounty.us> Vern, I've reviewed the design for the aforementioned system and it looks pretty straight -forward. I'd like to see the raw data for the percolation test and whether soil profile indicated horizons at particular depths. The LTAR of 1.2gal / sq. ft./ day is appropriate for course sands and matches the percolation rate but I'd like to see if any more restrictive or slower percolating soils are present beneath the soil treatment area, especially assuming that biomat would be formed slowing the movement of wastewater through the soil horizons. Was a sieve analysis performed? I'm wondering if there is more fine material than meets the eye present. Other comments are as follows: On the second page of the report, the paragraph that discusses installation indicates a 8" minimum soil cover over the tank lids and that should actually read "maximum". This is rectified later in the design. Notes 4 & 5 seem to not apply to this installation and can be removed. I noticed that sewer line will be beneath the driveway and that the tank is quite a ways away. This means that solids and liquids have a pretty long distance to travel. What do you think about using heavy pipe (schedule 80) or sleeving the pipe and installing a cleanout just beyond the driveway? You may want to insulate this as well. Infiltrator's shop drawing regarding placement of fill within the zone of treatment (page 6 of the report) seems to fit with Note #5 but doesn't seem applicable to this site. Am I missing something? I understand that you are installing this yourself so there shouldn't be any mis-communication between the engineer and the installer. I'm just trying to make sure the record is as clean as we can get it. Anything you can send electronically is greatly appreciated. Thanks! Raymond P. Merry, REHS Director of Environmental Health PO Box 179 Eagle, CO 81631 970.328.8757 ray. merry@eaglecounty. us AThanks for not printing electronic media https://mail.google.com/mail/?ui=2&ik=30478a9c52&view=pt&search=inbox&th=13829372900bd398 1 /1 BROCK CONSULTING, LLc Professional Services September 28, 2012 VIA Hand Delivery Eagle County Building Department P.O. Box 850 Eagle, CO 81631 876 Mesa Drive P.O.B. 3644 Eagle, CO 81631 Direct 970-471-2121 Fax 970-328-0875 brockconsulting Ocenturytel. net Reference: Engineering Certification Letter for Eaton Residence Permit # OWTS 6-12-7627 Edwards, Colorado Dear Department of Environmental Health: Please accept this certification letter, as -built drawing and pictures as certification of the OWTS serving the subject Eaton Residence at 425 County Road, Edwards, Colorado in Eagle County, Colorado has been installed as reflected on the As Built Drawing, attached, and constructed per Eagle County Septic Regulations by licensed septic installer Vern L. Brock (license #35-12) and general contractor/owner Mike Eaton. The primary deviations from the original plan are: • The septic exited the building on the west side and the distance to the tank was reduced due to internal plumbing and solids transfer. • The tank was increased to 1500 gal (concrete Copeland tank as original) per owner for future expansion. If you have any concerns with this submittal, please call me. incerely, Vern L. Brock, P.E. Brock Consulting, LLC cc: Mike Eaton Attachments: AS -BUILT DRAWING, 9/28/12 Pictures RE Q`v0, q_1 �" 0 •�v • Os sf0,0 �i N,A� 1Z BROCK CONSULTING, LLC ACTUAL DIMENSIONS TO FACILITIES SEPTIC TANK TO BUILDING SEPTIC TANK TO WATER LINE SEPTIC TANK TO ABSORPTION TRENCHES SEPTIC TANK TO WELL ABSORPTION TRENCHES TO BUILDING ABSORPTION TRENCHES TO WATER LINE ABSORPTION TRENCHES TO IRRIGATION DITCH ABSORPTION TRENCHES TO WELL BUILDING SEWER TO WATER LINE Measured September 28, 2012 Eaton Septic System Page 1 of I BCLLC ACTUAL (MIN. REQ'D) 12 FT (5 FT) 23 FT (10 FT) 85 FT (10 FT) 94 FT (50 FT) 85 FT (20 FT) 125 FT (25 FT) 75 FT (50 FT) 175 FT (100 FT) 10 FT (10 FT) R �uy.yc�mu.aeews�n.uwpoa sLSO-9Z£ (OL6) XVd OOV210"100 'AINnoO 31JV3 --! - —:snu nrmnm rwni�a LZLZ—LLb (OL6) 301dd0 IISIHX3 L£9L9 OOVMOloo '31OV3 3AIM0 VS3W 9L9 311S3YVOH NOIV3 ae rwvea a o s Olt "c)NIllnSNOO >IOONB NVId MUS '- :nru—avoaaav Ae sac..� s 12 M r W� N A' ♦4 N 3 v ° 43 fyj J�,q an)-7c,4 Q 41 f� 1� Y . a fit dl' I 4 In I� wn - a Q - r s x r Iz Coxwicr_11,"Wl.. {. ospe467_ •} ` +. m & v ,,E 4,&, MIKE EATON OWTS # 6-12-7627 PICTURES DATE VARIES